Open Access
CC BY-NC-ND 4.0 · Eur J Dent 2017; 11(02): 180-185
DOI: 10.4103/ejd.ejd_312_16
Original Article
Dental Investigation Society

In vitro evaluation of microleakage under orthodontic brackets bonded with different adhesive systems

Ramin Atash
1   Department of Stomatology and Dentistry, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium
,
Ali Fneiche
1   Department of Stomatology and Dentistry, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium
,
Sibel Cetik
2   Department of Stomatology and Dentistry, Erasmus Hospital and Laboratory of Physiology and Pharmaceutics, Faculty of Medicine, Université Libre de Bruxelles, Brussels, Belgium
,
Babak Bahrami
1   Department of Stomatology and Dentistry, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium
,
Alain Balon-Perin
1   Department of Stomatology and Dentistry, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium
,
Maria Orellana
1   Department of Stomatology and Dentistry, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium
,
Régine Glineur
1   Department of Stomatology and Dentistry, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium
› Author Affiliations
Further Information

Publication History

Publication Date:
23 September 2019 (online)

Preview

ABSTRACT

Objective: Adhesives systems have a drawback when utilized for bonding orthodontic brackets: they shrink during photopolymerization creating microleakage. The aim of this study was to assess the stability of different orthodontic adhesives around brackets and enamel. Materials and Methods: Sixty noncarious mandibular premolars extracted for orthodontic reasons were randomly divided into six groups of adhesives used for bonding brackets to dental enamel: NeoBond® Light Cure Adhesive Kit, Transbond™ Plus Self-Etching, Victory V-Slot APC PLUS® + Transbond™ MIP, Rely-A-Bond® Kit, Light Cure Orthodontic Adhesive Kit (OptiBond®), and Transbond™ MIP. Following bonding, all teeth underwent 2500 cycles of thermal cycling in baths ranging from 5°C to 55°C before being immersed in 2% methylene blue for 24 h. All samples were examined under a binocular microscope to assess the degree of microleakage at the “bracket-adhesive” and “adhesive-enamel” interfaces in the gingival and occlusal regions of the bracket. Results: A significant difference was found at the “occlusal bracket-adhesive” interface. The highest microleakage values were found in the occlusal region, although no significant. Microleakage was observed in all groups. Conclusion: Group 2 had the highest microleakage values whereas Group 6 had the lowest values.