CC BY-NC-ND 4.0 · European Journal of General Dentistry 2012; 1(03): 125-130
DOI: 10.4103/2278-9626.105350
Review Article

Maxillary immediate implant loading: A comprehensive review

Sagar J. Abichandani
Department of Prosthodontics, SDM College of Dental Sciences, Dharwad, Karnataka, India
,
Ramesh Nadiger
Department of Prosthodontics, SDM College of Dental Sciences, Dharwad, Karnataka, India
› Institutsangaben

Abstract

The incredible achievement of osseointegration and certainty of implant treatment modality in the mandible has provoked investigations, to look in the maxillary segment to check and understand if similar success rates can be achieved. This assessment of literature regarding this will give us knowledge about the various treatment modalities and investigations in an attempt understand the predictability and longevity of immediate implant loading in the maxilla carried out by various researchers. The basic nomenclature are considered and discussed, along with advantages and disadvantages of immediate loading, its relationship to osseointegration, its influence on primary stability and micro-motion. Excess weightage has been given to prosthodontically driven implant modality keeping the end-result in mind. Successful implementation of implant restorations can be done with the help of a few proposed guidelines.



Publikationsverlauf

Artikel online veröffentlicht:
01. November 2021

© 2012. European Journal of General Dentistry. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/.)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, et al. Osseointegrated implants in the treatment of edentulous jaw: Experience from a 10 year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.
  • 2 Wang HL, Boyapati L."PASS" principles for predictable bone regeneration. Implant Dent 2006;15:8-17.
  • 3 Chiapasco M. Early and intermediate restoration and loading of implants in completely edentulous patients. Int J Oral Maxillofac Implants 2004;19:76-91.
  • 4 Misch CE, Wang HL, Misch CM, Sharawy M, Lemons L, Judy KW. Rationale for the application of immediate load in implant dentistry: Part I. Implant Dent 2004;13:207-17.
  • 5 Misch CE, Wang HL, Misch CM, Sharawy M, Lemons L, Judy KW. Rationale for the application of immediate load in implant dentistry: Part I. Implant Dent 2004;13:310-21.
  • 6 Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1 5 year data. Int J Oral Maxillofac Implants 1997;12:319-24.
  • 7 Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410.
  • 8 Cochran DL, Morton D, Weber HP. Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants. Int J Oral Maxillofac Implants 2004;19(Suppl):109-13.
  • 9 Degidi M, Piatelli A, Gehrke P, Felice P, Carinci F. Five year outcome of 111 immediate non functional single restorations. J Oral Implantol 2006;32:277-85.
  • 10 Schwartz Arad D, Levin L. Symphysis revisited: Clinical and histologic evaluation of newly formed bone and harvesting potential previously used symphyseal donor sites for onlay bone grafting. J Periodontol 2009;80:865-69.
  • 11 Ostman PO, Hellman M, Wendelhag I, Sennerby L. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006;19:77-83.
  • 12 Hammerle CH, Chen ST, Wilson TG Jr. Consensus statements and recommended clinical procedures regarding the placement of implants in extraction sockets. Int J Oral Maxillofac Implants 2004;19(Suppl):26-8.
  • 13 Chen ST, Wilson TG Jr, Hammerle CH. Immediate or early placement of implants following tooth extraction: Review of biologic basis, clinical procedures and outcomes. Int J Oral Maxillofac Implants 2004;19(Suppl):12-25.
  • 14 Avila G, Galindo P, Rios H, Wang HL. Immediate implant loading: Current status from available literature. Implant Dent 2007;16:235-45.
  • 15 Canullo L, Goglia G, Iurlaro G, Ianello G. Short term bone level observations associated with platform switching in immediate placed and restored single maxillary implants a preliminary report. Int J Prosthodont 2009;22:277-82.
  • 16 Dierens M, Collaert B, Deschepper E, Broawaeys H, Klinge B, De Bruyn H. Patient centered outcome of immediately loaded implants in the rehabilitation of fully edentulous jaws. Clin Oral Implants Res 2009;20:1070-7.
  • 17 Collaert B, de Bruyn H. Immediate functional loading of TiOblast dental implants in full arch edentulous maxillae: 3 year prospective study. Clin Oral Implant Res 2008;19:1254-60.
  • 18 Morton D, Jaffin R, Weber HP. Immediate restoration and loading of dental implants: Clinical considerations and protocols. Int J Oral Maxillofac Implants 2004;19(Suppl):103-08.
  • 19 Mijiritsky E, Mardinger O, Mazor Z, Chaushu G. Immediate provisionalization of single tooth implants in fresh extraction sites at the maxillary esthetic zone: Upto 6 years follow up. Implant Dent 2009;18:326-33.
  • 20 Nordin T, Graf J, Frykholm A, Hellden L. Early functional loading of sandblasted and acid etched Staumann implants following immediate placement in maxillary extraction sockets: Clinical and radiographic results. Clin Oral Implants Res 2007;18:441-51.
  • 21 Degidi M, Piatelli A. Comparative analysis study of 702 implants subjected to immediate functional loading and immediate non functional loading to traditional healing periods with a follow up of upto 24 months. Int J Oral Maxillofac Implants 2005;20:99-107.
  • 22 Lekholm U, Zarb GA. Patient selection and preparation. Tissue Integrated Prosthesi: Osseointegration in clinical dentistry. Chicago, III: Quintessence Publishing Co; 1985. p. 199-209.
  • 23 Degidi M, Piatelli A. Immediate functional and non functional loading of dental implants: 2 60 month follow up study of 646 implants. J Periodontol 2003;74:225-41.
  • 24 Trisi P, Perfetti G, Baldoni E, Berardi D, Colagiovanni M, Scogna G. Implant micromotion is related to peak insertion torque and bone density. Clin Oral Implant Res 2009:20:467-71.
  • 25 Lioubavina Hack N, Lang NP, Karring T. Significance of primary stability for osseointegration of dental implants. Clin Oral Implant Res 2006;17:244-50.
  • 26 Ibanez JC, Tahhan MJ, Zamar JA, Menendez AB, Juaneda AM, Zamar NJ, et al. Immediate occlusal loading of double acid etched surface titanium implants in 41 consecutive full arch cases in the mandible and maxilla: 6 to 74 month results. J Periodontol 2005;76:1972-81.
  • 27 Irinakis T, Wiebe C. Clinical evaluation of the NobelActive implant system: Case series of 107 consecutively placed implants and a review of implant features. J Oral Implantol 2009;35:283-8.
  • 28 Cooper L, De Kok IJ, Reside GJ, Pungpapong P, Rojas Vizcaya F. Immediate fixed restoration of the edentulous maxilla after implant placement. J Oral Maxillofac Surg 2005;63(9 Suppl 2):97-110.
  • 29 Guida L, Lezzi G, Annuziata M, Salierno A, Iuorio G, Costigliola G, et al. Immediate placement and loading of dental implants A human histologic case report. J Periodontol 2008;79:575-81.
  • 30 Romanos GE, Toh CG, Siar CH, Wicht H, Yacoob H, Nentwig GH. Bone implant interface around titanium implants under different loading conditions: A histomorphometric analysis in the Macaca fascicularis monkey. J Periodontol 2003;74:1483-90.
  • 31 Rocci A, Martignoni M, Burgos PM, Gottlow J, Sennerby L. Histology of retrieved immediately and early loaded oxidized implants: Light microscopic observations after 5 to 9 months of loading in posterior maxilla. Clin Implant Dent Relat Res 2003;5(Suppl 1):88-98.
  • 32 Schnitman PA. Education in implant dentistry. J Am Dent Assoc 1990;121:3330-2.
  • 33 Roberts WE. Bone Dynamics of osseointegration, ankylosis and tooth movement. J Indiana Dent Assoc 1999 Fall;78:24-32.
  • 34 Anitua E, Orive G, Aguirre JJ, Andia I. Clinical outcome of immediately loaded dental implants bioactivated with plasma rich in growth factors: 5 year retrospective study. J Periodontol 2008;79:1168-76.
  • 35 Cameron HU, Pilliar MB, MacNab I. Effect of movement on the bonding of porous metal to bone. J Biomed Mater Res 1973;7:301-11.
  • 36 Szmukler Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone implant interface: Review of experimental literature. J Biomed Mater Res 1998;43:192-203.
  • 37 Bhola M, Neely AL, Kolhatkar S. Immediate implant placement: Clinical decisions, advantages, disadvantages. J Prosthodont 2008;17:576-81.
  • 38 Nkenke E, Fenner M. Indications for immediate loading of implants and implant success. Clin Oral Implant Res 2006;17(Suppl):19-34.
  • 39 Ganeles J, Wismeijer D. Early and immediately restored and loaded dental implants for single tooth and partial arch applications. Int J Oral Maxillofac Implants 2004;19(Suppl):92-102.
  • 40 Irinakis T, Wiebe C. Initial torque stability of a new bone condensing implants: Cohort study of 140 consecutively placed implants. J Oral Implantol 2009;35:277-82.
  • 41 Degidi M, Piatelli A, Shibli JA, Perrotti V, Iezzi G. Bone formation around immediately loaded and submerged implants with a modified sandblasted and acid etched surface after 4 and 8 weeks: Human histologic and histomorphometric analysis. Int J Oral Maxillofac Implants 2009;24:896-901.
  • 42 Martinez H, Davarpanah M, Missika P, Celleti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res 2001;12:423-32.
  • 43 Wyatt CC, Pharoah MJ. Imaging techniques and image interpretation for dental implant treatment. Int J Prosthodont 1998;11:442-52.
  • 44 Overgaad S, Bromose U, Lind M, Bunger C, Søballe K. Influence of crystallinity of the hydroxyappetite coating on fixation of implants: Mechanical and histomorphometric results. J Bone Joint Surg Br 1999;81:725-31.
  • 45 Ottoni JM, Oliveira ZF, Mansini R, Cabral AM. Correlation between placement torque and survival of single tooth implants. Int J Oral Maxillofac Implants 2005;20:769-76.
  • 46 Neugebauer J, Traini T, Tham U, Piatelli A, Zöller JE. Peri implant bone organization under immediate loading state: Circularly polarized light analysis: A minipig study. J Periodontol 2006;77:152-60.
  • 47 Hassan KS, Kassim A, Al Ogaly AU. A comparative evaluation of immediate dental implant with autogenous versus synthetic guided bone regeneration. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:e8-15.
  • 48 Lekovic V, Camargo PM, Klokkevold PR, Weinlaender M, Kenney EB, Dimitrijevic B, et al. Preservation of alvelolar bone in extraction sockets using bioabsorbable membranes. J Periodontol 1998;69:1044-9.
  • 49 Schropp L, Wenzel A, Kostopoulos L, Karring T. Bone healing and soft tissue contour changes following single tooth extraction: Clinical and radiographic 12 month prospective study. Int J Periodontics Restorative Dent 2003;23:313-23.
  • 50 Irinakis T. Rationale for socket preservation after extraction of single rooted tooth when planning for future implant placement. J Can Den Assoc 2006;72:917-22.
  • 51 Kan JY, Rungcharassaeng K, Lozada J. Immediate placement and provisionalization of maxillary anterior single implants: 1 year prospective study. Int J Oral Maxillofac Implants 2003;18:31-9.
  • 52 Bengazi F, Wennstom JL, Leklolm U. Recession of the soft tissue margin at oral implants: 2 year longitudinal prospective study. Clin Oral Implants Res 1996;7:303-10.
  • 53 Small PN, Tarnow DP. Gingival recession around implants: A 1 year longitudinal prospective study. Int J Oral Maxillofac Implants 2000;15:527-32.
  • 54 Hui E, Chow J, Li D, Lui J, Wat P, Law H. Immediate provisional for single tooth implant replacement with Branemark system: Preliminary report. Clin Implant Dent Relat Res 2001;3:79-86.
  • 55 Glauser R, Lundgren AK, Gottlow J, Sennerby L, Portmann M, Ruhstaller P, et al. Immediate occlusal loading of Branemark TiUnite implants placed redominantly in the soft bone: 1 year results of prospective clinical study. Clin Implant Dent Relat Res Abichandani and Nadiger: Maxillary immediate implant loading 2003;5(Suppl 1):47-56.
  • 56 Wang HL, Ormianer Z, Palti ML, Perel ML, Trisi P, Sammartino G. Consensus conference on immediate loading: Single tooth and partial edentulous areas. Implant Dent 2006;15:324-33.
  • 57 Chee W, Jivraj S. Efficiency of immediately loaded mandibular full arch implant restorations. Clin Implants Dent Relat Res 2003;5:52-6.
  • 58 Ganeles J, Rosenberg MM, Holt RL, Reichman LH. Immediate loading of implants with fixed restorations in a completely edentulous mandible: Report of 27 patients from a private practice. Int J Oral Maxillofac Implants 2001;16:418-26.
  • 59 Rapley JW, Mills MP, Wylam J. Soft tissue management during implant maintenance. Int J Periodontics Restorative Dent 1992;12:373-81.
  • 60 Simons AM, Darany DG, Giordano JR. The use of free gingival grafts in the treatment of peri implant soft tissue complications: Clinical report. Implant Dent 1993 Spring;2:27-30.
  • 61 Han TJ, Klokkevold PR, Takei HH. Strip gingival autograft used to correct mucogingival problems around implants. Int J Periodontics Restorative Dent 1995;15:404-11.
  • 62 Maksoud MA. Manipulation of peri implant tissue for better maintenance: A periodontal perspective. J Oral Implantol 2003;29:120-3.
  • 63 Cairo F, Pagliaro U, Nieri M. Soft tissue management at implant site. J Clin Periodontol 2008;35 (8 Suppl):163-7.
  • 64 Kim YK, Kim SG, Oh HK, Choi YG, Cho YS, Oh YH, et al. Evaluation of peri implant tissue in non submerged dental implants: A multicenter retrospective study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;108:189-95.
  • 65 Bouri A Jr, Bissada N, Al Zahrani MS, Faddoul F, Nouneh I. Width of keratinized gingiva and the health status of the supporting tissues around dental implants. Int J Oral Maxillofac Implants 2008;23:323-6.
  • 66 Fuster Torres MA, Albalat Estela S, Alcaniz Raya M, Penarrocha Diago M. CAD/CAM dental systems in implant dentistry: Update. Med Oral Patol Oral Cir Bucal 2009;14:E141-5.
  • 67 Crespi R, Cappare P, Gherlone E. Fresh socket implants in periapical infected sites in humans. J Periodontol 2010;81:378-83.
  • 68 Siegenthaler DW, Jung RE, Roos M, Hammerle CH. Replacement of teeth exhibiting periapical pathology by immediate implants: A prospective, controlled clinical trial. Clin Oral Implants Res 2007;18:727-37.
  • 69 Casap N, Zeltser C, Wexler A, Tarazai E, Zeltser R. Immediate placement of dental implants into debrided infected dentoalveolar sockets. J Oral Maxillofac Surg 2007;65:384-92.
  • 70 Blanchaert RH. Implants in medically challenged patients. Dent Clin North Am 1998;42:35-45.
  • 71 Degidi M, Nardi D, Piatelli A. Immediate loading of edentulous maxilla with a final restoration supported by an intra oral welded titanium bar: A case series of 20 consecutive cases. J Periodontol 2008;79:2207-13.
  • 72 Lee JH, Frias V, Lee KW, Wright RF. Effect of implant size and shape on implant success rates: A literature review. J Prosthet Dent 2005;94:377-81.
  • 73 Gervais MJ, Wilson PR. A rationale for retrievibility of fixed, implant supported prosthesis: A complication based analysis. Int J Prosthodont 2007;20:13-24.
  • 74 Bergkvist G, Sahlholm S, Karlsson U, Nilner K, Lindh C. Immediate loaded implants supporting fixed prosthesis in the edentulous maxilla: A clinical report. Int J Oral Maxillofac Implants 2005;20:399-405.
  • 75 Jaffin RA, Kumar A, Berman CL. Immediate loading of dental implants in completely edentulous maxilla: A clinical report. Int J Maxillofac Implants 2004;19:721-30.
  • 76 Tealdo T, Bevilacqua M, Pera F, Menini M, Ravera G, Drago C, et al. Immediate function with fixed implant supported maxillary denture: 12 months pilot study. J Prosthet Dent 2008;99:351-60.
  • 77 Pieri F, Aldini NN, Fini M, Corinaldesi G. Immediate occlusal loading of immediately placed implants supporting fixed restorations in completely edentulous arches: A 1 year prospective pilot study. J Periodontol 2009;80:411-21.
  • 78 Ostman PO, Hellman M, Sennerby L. Immediate occlusal loading of implants in the partially edentate mandible: A prospective 1 year radiographic and 4 year clinical study. Int J Oral Maxillofac Implants 2008;23:315-22.
  • 79 Testori T, Del Fabbro M, Feldman S, Vincenzi G, Sullivan D, Rossi R Jr, et al. A multicenter Prospective evaluation of 2 months loaded Osseotite implants placed in posterior jaws: A 3 year follow up study. Clin Oral Implants Res 2002;13:154-61.
  • 80 Agliardi EL, Francetti L, Romeo D, Taschieri S, Del Fabbro M. Immediate loading in a fully edentulous maxilla without bone grafting: The V II V technique. Minerva Stomatol 2008;57:251-9.
  • 81 Pieri F, Aldini NN, Fini M, Marchetti C. Immediate occlusal loading of immediately placed implants supporting fixed restorations in completely edentulous arches: A 1 year prospective pilot study. J Periodontol 2009;80:411-21.