Subscribe to RSS

DOI: 10.4103/1305-7456.120676
Effect of rotatory instrument speed on its capacity to remove demineralized and sound dentin
Publication History
Publication Date:
26 September 2019 (online)

ABSTRACT
Objectives: The aim of this study was to evaluate the capacity of two rotatory instruments (controlled speed electric motor [CSEM] - 300 rpm; conventional slow handpiece [CSHP] - 18,000 rpm) to remove sound and demineralized dentin, by examining prepared cavity walls using the scanning electron microscopy (SEM) and assessing loss of mass. Materials and Methods: A total of 40 blocks of human occlusal dentin, measuring 5 mm × 5 mm × 4 mm (L × W × H), were divided into two groups according to the substrate type in which the cavity preparation was performed: D - demineralized dentin; and S - sound dentin (control group). The groups were subdivided according to the rotatory instrument used for cavity preparation (n = 10): CSEM (300 rpm); and CSHP (18,000 rpm). In half of the dentin blocks, caries lesion induction was performed for 6 weeks. The preparation of the cavities was performed on a standardizing machine, using a cylindrical tungsten carbide burr. Before and after the preparation, specimens were dehydrated in an incubator at 60C for 30 min. The initial and final mass (in mg) of each dentin block was measured 3 times using the digital precision balance to obtain the mean weight Following cavity preparation, all specimens were hemisected and SEM was used to blindly assess each half so that the lateral walls of the prepared cavity were measured in μm, accepting the average of two measurements as the total depth of the preparation. Non-parametric Mann-Whitney analysis was performed with a 5% of significance level. Results: Regarding the weight difference (mg), no significance was detected between the groups. Regarding depth (μm), a significant difference was found between the groups, so that the CSRM showed lower cavity depth when compared with CSHP, both in sound and demineralized dentin. Conclusions: Controlled speed rotatory instruments were found to be more conservative in removing both sound and demineralized dentin, in terms of preparation and depth.
-
REFERENCES
- 1 Yip HK, Samaranayake LP. Caries removal techniques and instrumentation: A review. Clin Oral Investig 1998; 2: 148-54
- 2 Fusayama T. Two layers of carious dentin; diagnosis and treatment. Oper Dent 1979; 4: 63-70
- 3 Bjørndal L, Larsen T, Thylstrup A. A clinical and microbiological study of deep carious lesions during stepwise excavation using long treatment intervals. Caries Res 1997; 31: 411-7
- 4 Tyas MJ, Anusavice KJ, Frencken JE, Mount GJ. Minimal intervention dentistry: A review FDI commission project 1-97. Int Dent J 2000; 50: 1-12
- 5 Vieira AS, dos Santos MP, Antunes LA, Primo LG, Maia LC. Preparation time and sealing effect of cavities prepared by an ultrasonic device and a high-speed diamond rotary cutting system. J Oral Sci 2007; 49: 207-11
- 6 Banerjee A, Watson TF, Kidd EA. Dentine caries excavation: A review of current clinical techniques. Br Dent J 2000; 188: 476-82
- 7 Banerjee A, Kidd EA, Watson TF. In vitro evaluation of five alternative methods of carious dentine excavation. Caries Res 2000; 34: 144-50
- 8 Shovelton DS. The maintenance of pulp vitality. Br Dent J 1972; 133: 95-101
- 9 Yildirim M, Seymen F, Keklikoglu N. The evaluation of the vector system in removal of carious tissue. Int J Dent 2010 2010; 821357
- 10 Stanley HR, Swedlow H. Biological effects of various cutting methods in cavity preparation: The part pressure plays in pulpal response. J Am Dent Assoc 1960; 61: 450-6
- 11 Maragakis GM, Hahn P, Hellwig E. Chemomechanical caries removal: A comprehensive review of the literature. Int Dent J 2001; 51: 291-9
- 12 Dammaschke T, Vesnic A, Schafer E. In vitro comparison of ceramic burs and conventional tungsten carbide bud burs in dentin caries excavation. Quintessence Int 2008; 39: 495-9
- 13 Yazici AR, Ozgünaltay G, Dayangaç B. A scanning electron microscopic study of different caries removal techniques on human dentin. Oper Dent 2002; 27: 360-6
- 14 Peters OA, Paque F. Current developments in rotary root canal instrument technology and clinical use: A review. Quintessence Int 2010; 41: 479-88
- 15 Daugherty DW, Gound TG, Comer TL. Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm. J Endod 2001; 27: 93-5
- 16 Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995; 21: 146-51
- 17 Taºdemir T, Aydemir H, Inan U, Unal O. Canal preparation with hero 642 rotary Ni-Ti instruments compared with stainless steel hand K-file assessed using computed tomography. Int Endod J 2005; 38: 402-8
- 18 Raucci-Neto W, Chinelatti MA, Ito IY, Pécora JD, Palma-Dibb RG. Influence of Er: YAG laser frequency on dentin caries removal capacity. Microsc Res Tech 2011; 74: 281-6
- 19 Lennon AM, Buchalla W, Rassner B, Becker K, Attin T. Efficiency of 4 caries excavation methods compared. Oper Dent 2006; 31: 551-5
- 20 Meller C, Welk A, Zeligowski T, Splieth C. Comparison of dentin caries excavation with polymer and conventional tungsten carbide burs. Quintessence Int 2007; 38: 565-9
- 21 Isik EE, Olmez A, Akca G, Sultan N. A microbiological assessment of polymer and conventional carbide burs in caries removal. Pediatr Dent 2010; 32: 316-23
- 22 Celiberti P, Francescut P, Lussi A. Performance of four dentine excavation methods in deciduous teeth. Caries Res 2006; 40: 117-23
- 23 Prabhakar A, Kiran NK. Clinical evaluation of polyamide polymer burs for selective carious dentin removal. J Contemp Dent Pract 2009; 10: 26-34
- 24 Corrêa FN, Rocha RO, Soares FZ, Rodrigues-Filho LE, Rodrigues CR. Fluorescence of primary dentine after chemomechanical and conventional rotary excavation. Eur Arch Paediatr Dent 2008; 9: 126-9
- 25 Colucci V, do Amaral FL, Pécora JD, Palma-Dibb RG, Corona SA. Effects of water flow on ablation rate and morphological changes in human enamel and dentin after Er: YAG laser irradiation. Am J Dent 2012; 25: 332-6
- 26 Limongi O, Bernardes AV, Netto PR, Melo TA, Soares RG. Analysis of the produced consuming in the root canals preparation with oscilatory system in three diferente speeds. Rev Odontol Univ Cid São Paulo 2009; 21: 14-7
- 27 Delméa KI, De Moor RJ. A scanning electron microscopic comparison of different caries removal techniques for root caries treatment. J Oral Laser Appl 2003; 3: 235-42
- 28 Messias DC, Souza-Gabriel AE, Palma-Dibb RG, Rodrigues Jr AL, Serra MC. Efficiency and effectiveness of Er: YAG laser on carious tissue removal. J Oral Laser Appl 2006; 6: 1-6