Subscribe to RSS

DOI: 10.4103/0971-3026.190408
Thumb ultrasound: Technique and pathologies
Financial support and sponsorship Nil.

Abstract
Ultrasound is ideally suited for the assessment of complex anatomy and pathologies of the thumb. Focused and dynamic thumb ultrasound can provide a rapid real-time diagnosis and can be used for guided treatment in certain clinical situations. We present a simplified approach to scanning technique for thumb-related pathologies and illustrate a spectrum of common and uncommon pathologies encountered.
Publication History
Article published online:
30 July 2021
© 2016. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).
Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India
-
References
- 1 Eaton RG, Glickel SZ. Trapeziometacarpal osteoarthritis: Staging as a rationale for treatment. Hand Clin 1987;3:455-71.
- 2 Rousset P, Vuillemin-Bodaghi V, Laredo JD, Parlier-Cuau C. Anatomic variations in the first extensor compartment of the wrist: Accuracy of US. Radiology 2010;257:427-33.
- 3 Choi SJ, Ahn JH, Lee YJ, Ryu DS, Lee JH, Jung SM, et al. de Quervain disease: US identification of anatomic variations in the first extensor compartment with an emphasis on subcompartmentalization. Radiology 2011;260:480-6.
- 4 Griffin M, Hindocha S, Jordan D, Saleh M, Khan W. An Overview of the management of flexor tendon injuries. Open Orthop J 2012;6:28-35.
- 5 Griffin M, Hindocha S, Jordan D, Saleh M, Khan W. Management of Extensor Tendon Injuries. Open Orthop J 2012;6:36-42.
- 6 Shields JS, Chhabra AB, Pannunzio ME. Acute calcific tendinitis of the hand: 2 case reports involving the abductor pollicis brevis. Am J Orthop 2007;36:605-7.
- 7 Guerini H, Pessis E, Theumann N, Le Quintrec JS, Campagna R, Chevrot A, et al. Sonographic appearance of trigger fingers. J Ultrasound Med 2008;27:1407-13.
- 8 Serafini G, Derchi LE, Quadri P, Martinoli C, Orio O, Cavallo A, et al. High resolution sonography of the flexor tendons in trigger fingers. J Ultrasound Med 1996;15:213-9.
- 9 Peters-Veluthamaningal C, van der Windt DA, Winters JC, Meyboom-de Jong B. Corticosteroid injection for trigger finger in adults. Cochrane Database Sys Rev 2009:CD005617.
- 10 Benson LS, Ptaszek AJ. Injection versus surgery in the treatment of trigger finger. J Hand Surg Am 1997;22:138-44.
- 11 Rajeswaran G, Lee JC, Eckersley R, Katsarma E, Healy JC. Ultrasound-guided percutaneous release of the annular pulley in trigger digit. Eur Radiol 2009;19:2232-7.
- 12 Ebrahim FS, De Maeseneer M, Jager T, Marcelis S, Jamadar DA, Jacobson JA. US diagnosis of UCL tears of the thumb and Stener lesions: Technique, pattern-based approach, and differential diagnosis. Radiographics 2006;26:1007-20.
- 13 Hergan K, Mittler C, Oser W. Pitfalls in sonography of the gamekeepers' thumb. Eur Radiol 1997;7:65-9.
- 14 Melville D, Jacobson JA, Haase S, Brandon C, Brigido MK, Fessell D. Ultrasound of displaced ulnar collateral ligament tears of the thumb: The Stener lesion revisited. Skeletal Radiol 2013;42:667-73.
- 15 Kosiyatrakul A, Jitprapaikulsarn S, Durand S, Oberlin C. Closed flexor pulley rupture of the thumb: Case report and review of literature. Hand Surg 2009;14:139-42.
- 16 Bayat A, Shaaban H, Giakas G, Lees VC. The pulley system of the thumb: Anatomic and biomechanical study. J Hand Surg Am 2002;27:628-35.
- 17 Bianchi S, Della Santa D, Glauser T, Beaulieu JY, van Aaken J. Sonography of masses of the wrist and hand. AJR Am J Roentgenol 2008;191:1767-75.
- 18 Teefey SA, Dahiya N, Middleton WD, Gelberman RH, Boyer MI. Ganglia of the hand and wrist: A sonographic analysis. AJR Am J Roentgenol 2008;191:716-20.
- 19 Wang G, Jacobson JA, Feng FY, Girish G, Caoili EM, Brandon C. Sonography of wrist ganglion cysts: Variable and noncystic appearances. J Ultrasound Med 2007;26:1323-8.
- 20 Middleton WD, Patel V, Teefey SA, Boyer MI. Giant cell tumors of the tendon sheath: Analysis of sonographic findings. AJR Am J Roentgenol 2004;183:337-9.
- 21 Fornage BD, Tassin GB. Sonographic appearances of superficial soft tissue lipomas. J Clin Ultrasound 1991;19:215-20.
- 22 Inampudi P, Jacobson JA, Fessell DP, Carlos RC, Patel SV, Delaney-Sathy LO, et al. Soft-tissue lipomas: Accuracy of sonography in diagnosis with pathologic correlation. Radiology 2004;233:763-7.
- 23 Marzano L, Failoni S, Gallazzi M, Garbagna P. The role of diagnostic imaging in synovial sarcoma: Our experience. Radiol Med 2004;107:533-40.
- 24 Boyse TD, Fessell DP, Jacobson JA, Lin J, van Holsbeeck MT, Hayes CW. US of soft-tissue foreign bodies and associated complications with surgical correlation Radiographics 2001;21:1251-6.
- 25 Tahmasebi M, Zareizadeh H, Motamedfar A. Accuracy of ultrasonography in detecting radiolucent soft-tissue foreign bodies. Indian J Radiol Imaging 2014;24:196-200.