Brief Report
An improvised two in one syringe suction drain for surgeries of extremities
Further Information
Publication History
Publication Date:
15 January 2020 (online)

Abstract
Use of an improvised two in one syringe suction drain is being presented for a case with two adjacent non-communicating surgical wounds following release of Duputryn′s contracture primarily involving the longitudinal band of the palmar fascia of the hand, in line with the middle and ring finger. Instead of using two separate closed suction drainage system we modified our method by using a 3 way cannula which could accept 2 draining tubes to be connected to one 50cc syringe with negative suction pressure.
- 1 Singh A, Thind MS, Mander KS, Singh GP. Syringe Suction Drain. Br J Plast Surg 1992; 45: 484
- 2 Park DH, Song CH, Han DG, Ahn KY, Byun JS. A simple negative suction drain for ear reconstruction. Plast Reconst Surg 1999; 103: 972
- 3 Selcuk A.. A Modified syringe suction drainage system. Plast Reconst Surg. 2004 113.