Abstract
Background:
The electrically evoked stapedial reflex threshold (ESRT) has been shown to be a good predictor of upper stimulation level for cochlear implant recipients. Previous research has shown that the ESRT may be recorded at lower stimulation levels and with a higher incidence of success with the use of higher frequency probe tones (e.g., 678 and 1000 Hz) relative to the use of the conventional 226-Hz probe tone. Research has also shown that the acoustic reflex may be recorded at lower stimulus levels with the use of wideband reflectance when compared to the acoustic reflex threshold recorded with a conventional acoustic immittance measurement.
Purpose:
The objective of this study was to compare the ESRT recorded with acoustic immittance and wideband reflectance measurements.
Research Design:
A repeated measures design was used to evaluate potential differences in ESRTs with stimulation at an apical, middle, and basal electrode contact with the use of two different techniques, acoustic immittance measurement and wideband reflectance.
Study Sample:
Twelve users of Cochlear Nucleus cochlear implants were included in the study.
Data Collection and Analysis:
Participants’ ESRTs were evaluated in response to simulation at three different electrode contact sites (i.e., an apical, middle, and basal electrode contact) with the use of two different middle ear measurement techniques, acoustic immittance with the use of a 226-Hz probe tone and wideband reflectance with the use of a chirp stimulus.
Results:
The mean ESRT recorded with wideband reflectance measurement was significantly lower when compared to the ESRT recorded with acoustic immittance. For one participant, the ESRT was not recorded with acoustic immittance before reaching the participant’s loudness discomfort threshold, but it was successfully recorded with the use of wideband reflectance
Conclusions:
The ESRT may potentially be recorded at lower presentation levels with the use of wideband reflectance measures relative to the use of acoustic immittance with a 226-Hz probe tone. This may allow for the ESRT to be obtained at levels that are more comfortable for the cochlear implant recipient, which may also allow for a higher incidence in the successful recording of the ESRT.
-
REFERENCES
- Allum JH, Greisiger R, Probst R. 2002; Relationship of intraoperative electrically evoked stapedius reflex thresholds to maximum comfortable loudness levels of children with cochlear implants. Int J Audiol 41 (02) 93-99
- Battmer RD, Laszig R, Lehnhardt E. 1990; Electrically elicited stapedius reflex in cochlear implant patients. Ear Hear 11 (05) 370-374
- Bresnihan M, Norman G, Scott F, Viani L. 2001; Measurement of comfort levels by means of electrical stapedial reflex in children. Arch Otolaryngol Head Neck Surg 127 (08) 963-966
- Brickley G, Boyd P, Wyllie F, O’Driscoll M, Webster D, Nopp P. 2005; Investigations into electrically evoked stapedius reflex measures and subjective loudness percepts in the MED-EL COMBI 40+ cochlear implant. Cochlear Implants Int 6 (01) 31-42
- Buckler L, Overstreet E. 2003. Relationship Between Electrical Stapedial Reflex Thresholds and Hi-Res Program Settings: Potential Tool for Pediatric Cochlear-Implant Fitting. Valencia, CA: Advanced Bionics;
- Cafarelli Dees D, Dillier N, Lai WK. 2005; Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the Nucleus CI24M cochlear implant system. Audiol Neurootol 10 (02) 105-116
- Feeney MP, Hunter LL, Kei J, Lilly DJ, Margolis RH, Nakajima HH, Neely ST, Prieve BA, Rosowski JJ, Sanford CA, Schairer KS, Shahnaz N, Stenfelt S, Voss SE. 2013; Consensus statement: Eriksholm workshop on wideband absorbance measures of the middle ear. Ear Hear 34 (01) (Suppl) 78S-79S
- Feeney MP, Keefe DH. 1999; Acoustic reflex detection using wide-band acoustic reflectance, admittance, and power measurements. J Speech Lang Hear Res 42 (05) 1029-1041
- Feeney MP, Keefe DH, Hunter LL, Fitzpatrick DF, Garinis AC, Putterman DB, McMillan GP. 2017 Normative wideband reflectance, equivalent admittance at the tympanic membrane, and acoustic stapedius reflex threshold in adults. Ear Hear http://journals.lww.com/ear-hearing/Abstract/publishahead/Normative_Wideband_Reflectance,_Equivalent.99124.aspx
- Feeney MP, Keefe DH, Marryott LP. 2003; Contralateral acoustic reflex thresholds for tonal activators using wideband energy reflectance and admittance. J Speech Lang Hear Res 46 (01) 128-136
- Feeney MP, Keefe DH, Sanford CA. 2004; Wideband reflectance measures of the ipsilateral acoustic stapedius reflex threshold. Ear Hear 25 (05) 421-430
- Franck KH, Xu L, Pfingst BE. 2003; Effects of stimulus level on speech perception with cochlear prostheses. J Assoc Res Otolaryngol 4 (01) 49-59
- Golding M, Doyle K, Sindhusake D, Mitchell P, Newall P, Hartley D. 2007; Tympanometric and acoustic stapedius reflex measures in older adults: the Blue Mountains Hearing Study. J Am Acad Audiol 18 (05) 391-403
- Gordon KA, Chaikof MH, Salloum C, Goulding G, Papsin B. 2012; Toward a method for programming balanced bilateral cochlear implant stimulation levels in children. Cochlear Implants Int 13 (04) 220-227
- Gordon KA, Papsin BC, Harrison RV. 2004; Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children. Ear Hear 25 (05) 447-463
- Hodges AV, Balkany TJ, Ruth RA, Lambert PR, Dolan-Ash S, Schloffman JJ. 1997; Electrical middle ear muscle reflex: use in cochlear implant programming. Otolaryngol Head Neck Surg 117 3 Pt 1 255-261
- Hodges AV, Balkany TJ, Ruth RA, Schloffman JJ. 1996 Equal loudness balancing using electrical middle ear muscle reflexes. Presented at the International Cochlear Implant, Speech and Hearing Symposium, Melbourne, Australia
- Holstad BA, Sonneveldt VG, Fears BT, Davidson LS, Aaron RJ, Richter M, Matusofsky M, Brenner CA, Strube MJ, Skinner MW. 2009; Relation of electrically evoked compound action potential thresholds to behavioral T- and C-levels in children with cochlear implants. Ear Hear 30 (01) 115-127
- Hughes ML, Brown CJ, Abbas PJ, Wolaver AA, Gervais JP. 2000; Comparison of EAP thresholds with MAP levels in the nucleus 24 cochlear implant: data from children. Ear Hear 21 (02) 164-174
- Hunter LL, Keefe DH, Feeney MP, Fitzpatrick DF. 2017; Pressurized wideband acoustic stapedial reflex thresholds: normal development and relationships to auditory function in infants. J Assoc Res Otolaryngol 18 (01) 49-63
- Hunter LL, Shahnaz N. 2014. Acoustic Immittance Measures: Basic and Advanced Practice. San Diego, CA: Plural Publishing, Inc.;
- Jerger J, Anthony L, Jerger S, Mauldin L. 1974; Studies in impedance audiometry. 3. Middle ear disorders. Arch Otolaryngol 99 (03) 165-171
- Jerger J, Jenkins H, Fifer R, Mecklenburg D. 1986; Stapedius reflex to electrical stimulation in a patient with a cochlear implant. Ann Otol Rhinol Laryngol 95 2 Pt 1 151-157
- Jerger J, Oliver TA, Chmiel RA. 1988; Prediction of dynamic range from stapedius reflex in cochlear implant patients. Ear Hear 9 (01) 4-8
- Keefe DH, Feeney MP, Hunter LL, Fitzpatrick DF. 2017; Aural acoustic stapedius-muscle reflex threshold procedures to test human infants and adults. J Assoc Res Otolaryngol 18 (01) 65-88
- Knutson JF, Hinrichs JV, Tyler RS, Gantz BJ, Schartz HA, Woodworth G. 1991; Psychological predictors of audiological outcomes of multichannel cochlear implants: preliminary findings. Ann Otol Rhinol Laryngol 100 (10) 817-822
- Lorens A, Walkowiak A, Piotrowska A, Skarzynski H, Anderson I. 2004; ESRT and MCL correlations in experienced paediatric cochlear implant users. Cochlear Implants Int 5 (01) 28-37
- Moog JS, Geers AE. 2003; Epilogue: major findings, conclusions and implications for deaf education. Ear Hear 24 (01) (Suppl) 121S-125S
- Nozza RJ, Bluestone CD, Kardatzke D, Bachman R. 1992; Towards the validation of aural acoustic immittance measures for diagnosis of middle ear effusion in children. Ear Hear 13 (06) 442-453
- Overstreet KH. 2004; New objective measurement techniques and their relationship to HiRes program settings. Int Congr Ser 1273: 35-39
- Pfingst BE, Holloway LA, Zwolan TA, Collins LM. 1999; Effects of stimulus level on electrode-place discrimination in human subjects with cochlear implants. Hear Res 134 1–2 105-115
- Polak M, Hodges AV, King JE, Balkany TJ. 2004; Further prospective findings with compound action potentials from Nucleus 24 cochlear implants. Hear Res 188 1–2 104-116
- Polak M, Hodges AV, King JE, Payne SL, Balkany TJ. 2006; Objective methods in postlingually and prelingually deafened adults for programming cochlear implants: ESR and NRT. Cochlear Implants Int 7 (03) 125-141
- Rubinstein JT, Parkinson WS, Tyler RS, Gantz BJ. 1999; Residual speech recognition and cochlear implant performance: effects of implantation criteria. Am J Otol 20 (04) 445-452
- Sainz M, de la Torre A, Roldán C, Ruiz JM, Vargas JL. 2003; Analysis of programming maps and its application for balancing multichannel cochlear implants. Int J Audiol 42 (01) 43-51
- Schairer KS, Ellison JC, Fitzpatrick D, Keefe DH. 2007; Wideband ipsilateral measurements of middle-ear muscle reflex thresholds in children and adults. J Acoust Soc Am 121 (06) 3607-3616
- Shahnaz N, Bork K. 2008; Comparison of standard and multi-frequency tympanometric measures obtained with the Virtual 310 system and the Grason-Stadler Tympstar. Canadian J Speech Lang Pathol Audiol 32: 146-157
- Shallop JK, Ash KR. 1995; Relationships among comfort levels determined by cochlear implant patient’s self-programming, audiologist’s programming, and electrical stapedius reflex thresholds. Ann Otol Rhinol Laryngol Suppl 166: 175-176
- Spivak LG, Chute PM. 1994; The relationship between electrical acoustic reflex thresholds and behavioral comfort levels in children and adult cochlear implant patients. Ear Hear 15 (02) 184-192
- Spivak LG, Chute PM, Popp AL, Parisier SC. 1994; Programming the cochlear implant based on electrical acoustic reflex thresholds: patient performance. Laryngoscope 104 (10) 1225-1230
- Stephan K, Welzl-Müller K. 2000; Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants. Audiology 39 (01) 13-18
- Stephan K, Welzl-Müller K, Stiglbrunner H. 1988; Stapedius reflex threshold in cochlear implant patients. Audiology 27 (04) 227-233
- Stephan K, Welzl-Müller K, Stiglbrunner H. 1990; Stapedius reflex growth function in cochlear implant patients. Audiology 29 (01) 46-54
- Stephan K, Welzl-Müller K, Stiglbrunner H. 1991; Acoustic reflex in patients with cochlear implants (analog stimulation). Am J Otol 12 (Suppl) 48-51
- Tait M, Lutman ME, Robinson K. 2000; Preimplant measures of preverbal communicative behavior as predictors of cochlear implant outcomes in children. Ear Hear 21 (01) 18-24
- Walkowiak A, Lorens A, Polak M, Kostek B, Skarzynski H, Szkielkowska A, Skarzynski PH. 2011; Evoked stapedius reflex and compound action potential thresholds versus most comfortable loudness level: assessment of their relation for charge-based fitting strategies in implant users. ORL J Otorhinolaryngol Relat Spec 73 (04) 189-195
- Wiley TL, Oviatt DL, Block MG. 1987; Acoustic-immittance measures in normal ears. J Speech Hear Res 30 (02) 161-170
- Wolfe J, Gilbert M, Schafer E, Litvak LM, Spahr AJ, Saoji A, Finley C.. 2017; Optimizations for the electrically-evoked stapedial reflex threshold measurement in cochlear implant recipients. Ear Hear 38 (02) 255-261
- Wolfe J, Kasulis H. 2008; Relationships among objective measures and speech perception in adult users of the HiResolution Bionic Ear. Cochlear Implants Int 9 (02) 70-81