Vet Comp Orthop Traumatol 2010; 23(05): 354-361
DOI: 10.3415/VCOT-10-01-0010
Case Report
Schattauer GmbH

Computer-assisted surgical correction of an antebrachial deformity in a dog

K. R. Crosse
1   Massey University Veterinary Teaching Hospital, Palmerston North, Manawatu, New Zealand
,
A. J. Worth
› Author Affiliations
Further Information

Publication History

Received: 27 January 2010

Accepted: 27 April 2010

Publication Date:
19 December 2017 (online)

Summary

Objective: To report the use of three dimensional (3D) computed tomographic (CT) imaging, computer simulation and rapid prototype modelling to aid surgical correction of a complex antebrachial deformity in a dog.

Methods: A six-year-old, 13 kg spayed female Chihuahua crossbreed dog was presented for worsening forelimb gait and exercise intolerance. Both forelimbs had gross angular limb deformity with carpal hyper-flexion, valgus and radial procurvatum. Surgical planning from radiographs was problematic therefore CT data were used to generate 3D reconstructions of the antebrachium. Using imaging software we then quantified the nature of the deformity using a previously unreported method based on the centre of rotation of angulation as a 3D model. Computer simulated closing of the virtual wedge osteotomy was then performed as proof of concept. A stereolithographic model complete with osteotomy axes, was then created in plastic using a rapid prototyping machine. Oscillating saw guides were fabricated in polymethylmethacrylate and cold sterilised. A closing wedge osteotomy with de-rotation was performed and stabilised with a pre-contoured dynamic compression plate. At the three- and six-month follow-up examinations there was improved weight-bearing and cosmetic appearance.

Conclusions: Computer assistance was valuable for locating and quantifying this antebrachial deformity and conceptualising the corrective surgery. The results of our study suggest that rapid prototyping can be used to create models and saw guides to simplify one-stage corrective osteotomies and more accurately treat angular limb deformity.

 
  • References

  • 1 Johnson JA, Austin C, Breur GJ. Incidence of canine appendicular musculoskeletal disorders in 16 Veterinary Teaching Hospitals from 1980 through 1989. Vet Comp Orthop Traumatol 1994; 7: 56-69.
  • 2 Fox SM. Premature closure of distal radial and ulnar physes in the dog 1. Pathogenesis and diagnosis. Compend Contin Edu Pract Vet 1984; 6: 128-39.
  • 3 Ramadan RO, Vaughan LC. Premature closure of the distal ulnar growth plate in dogs – a review of 58 cases. J Small Anim Pract 1978; 19: 647-67.
  • 4 O'Brien TR, Morgan JP, Suter PF. Epiphyseal plate injury in the dog: a radiographic study of growth disturbance in the forelimb. J Small Anim Pract 1971; 12: 19-36.
  • 5 Morgan PW, Miller CW. Osteotomy for correction of premature growth-plate closure in 24 dogs. Vet Comp Orthop Traumatol 1994; 7: 129-135.
  • 6 Henney LHS, Gambardella PC. Premature closure of the ulnar physis in the dog – a retrospective clinical study. J Am Anim Hosp Assoc 1989; 25: 573-581.
  • 7 Fox DB, Tomlinson JL, Cook JL. et al. Principles of uniapical and biapical radial deformity correction using dome osteotomies and the center of rotation of angulation methodology in dogs. Vet Surg 2006; 35: 67-77.
  • 8 Meola SD, Wheeler JL, Rist CL. Validation of a technique to assess radial torsion in the presence of procurvatum and valgus deformity using computed tomography: a cadaveric study. Vet Surg 2008; 37: 525-529.
  • 9 Captug O, Bilgili H. Correction of the antebrachial deformity using circular external skeletal fixator in 7 dogs. Polish J Vet Sci 2009; 12: 45-54.
  • 10 Sereda CW, Lewis DD, Radasch RM. et al. Descriptive report of antebrachial growth deformity correction in 17 dogs from 1999 to 2007, using hybrid linear-circular external fixator constructs. Can Vet J 2009; 50: 723-732.
  • 11 Dismukes DI, Fox DB, Tomlinson JL. et al. Use of radiographic measures and three-dimensional computed tomographic imaging in surgical correction of an antebrachial deformity in a dog. J Am Vet Med Assoc 2008; 232: 68-73.
  • 12 Marcellin-Little DJ, Ferretti A, Roe SC. et al. Hinged ilizarov external fixation for correction of antebrachial deformities. Vet Surg 1998; 27: 231-245.
  • 13 Balfour RJ, Boudrieau RJ, Gores BR. T-plate fixation of distal radial closing wedge osteotomies for treatment of angular limb deformities in 18 dogs. Vet Surg 2000; 29: 207-217.
  • 14 Theyse LFH, Voorhout G, Hazewinkel HAW. Prognostic factors in treating antebrachial growth deformities with a lengthening procedure using a circular external skeletal fixation system in dogs. Vet Surg 2005; 34: 424-435.
  • 15 Mahaisavariyaa B, Sitthiseripratipb K, Orisc P. Rapid prototyping model for surgical planning of corrective osteotomy for cubitus varus: Report of two cases. Injury Extra 2006; 37: 176-180.
  • 16 Murase T, Oka K, Moritomo H. et al. Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. J Bone Joint Surg Am 2008; 90: 2375-2389.
  • 17 Paley D. Frontal plane mechanical and anatomical axis planning. Herzenberg JE, editor. Principles of deformity correction [CD ROM]. Berlin: Springer-Verlag Berlin 2004; pgs 61-97.
  • 18 Bindra RR, Cole RJ, Yamaguchi K. et al. Quantification of the radial torsion angle with computerized tomography in cadaver specimens. J Bone Joint Surg Am 1997; 79 A 833-837.
  • 19 Murphy SB, Kijewski PK, Simon SR. et al. Computer-aided simulation, analysis and design in orthopaedic surgery. Ortho Clin N Am 1986; 17: 637-649.
  • 20 Webb PA. A review of rapid prototyping (RP) techniques in the medical and biomedical sector. J Med Eng Technol 2000; 24: 149-153.
  • 21 Harrysson OLA, Cormier DR, Marcellin-Little DJ. et al. Rapid prototyping for treatment of canine limb deformities. Rapid Prototyping Journal 2003; 9: 37-42.
  • 22 Faber J, Berto PM, Quaresma M. Rapid prototyping as a tool for diagnosis and treatment planning for maxillary canine impaction. Am J Orthod Dentofacial Orthop 2006; 129: 583-589.
  • 23 D'Urso PS, Barker TM, Earwaker WJ. et al. Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial. J Craniomaxillofac Surg 1999; 27: 30-37.
  • 24 Minns RJ, Bibb R, Banks R. et al. The use of a reconstructed three-dimensional solid model from CT to aid the surgical management of a total knee arthroplasty: a case study. Med Eng Phys 2003; 25: 523-526.
  • 25 Kim MS, Hansgen AR, Wink O. et al. Rapid prototyping: A new tool in understanding and treating structural heart disease. Circulation 2008; 117: 2388-2394.