A 2 mm drill broke during plate fixation of an ilial fracture. Postoperative radiographs
showed the tip of the drill bit to be within the L7 vertebral canal. It was retrieved
10 days later via dorsal laminectomy, immediately restoring weight bearing.
Keywords
Ilial fracture - drill bit breakage - vertebral canal foreign body - dorsal laminectomy