Klinische Neurophysiologie 1984; 15(3): 142-144
DOI: 10.1055/s-2008-1061011
© Georg Thieme Verlag Stuttgart · New York

Quantifizierungsmethoden des EEG zur Verbesserung der Diagnosestellung bei Multipler Sklerose

Amelioration of M.S. diagnosis by new methods of EEG quantificationL. Ponsen, E. J. Jonkman, A. W. de Weerd, A. C. van Huffelen
  • Forschungseinheit für Klinische Neurophysiologie TNO, Westeinde Ziekenhuis, Den Haag
Further Information

Publication History

Publication Date:
18 March 2008 (online)

Summary

The quantified EEG was studied in 20 patients with multiple sclerosis. The results were compared with those of a matched control group of normal volunteers. Abnormalities in the quantified EEG could be demonstrated in 50 % of the MS patients. The value of the method in clinical practice, however, is limited: 95 % of our patients showed abnormal results of the CSF analysis and/or EP studies. It seems advisable to use computer analysis of the EEG only in those MS patients in whom the much simpler EP recordings and CSF analysis does not lead to conclusive results.

Zusammenfassung

Das quantifizierte EEG wurde bei 20 Patienten mit Multipler Sklerose studiert. Die Ergebnisse wurden verglichen mit denen einer Kontrollgruppe von normalen Freiwilligen. Abnormalitäten im quantifizierten EEG waren bei 50 % der MS-Patienten festzustellen. Dennoch ist der Nutzen dieser Methode in der klinischen Praxis beschränkt: 95 % unserer Patienten zeigten bei Analyse des Liquor cerebro spinalis und/oder Untersuchungen evozierter Potentiale abnorme Ergebnisse. Es empfiehlt sich, Computer-Auswertungen des EEG nur bei solchen MS-Patienten anzuwenden, bei denen die viel einfacheren EP-Aufnahmen und Liquor-Analysen nicht zu deutlichen Ergebnissen führen.