Minim Invasive Neurosurg 1998; 41(2): 58-61
DOI: 10.1055/s-2008-1052017
DOI: 10.1055/s-2008-1052017
MiniMATCH: A Simple Method for Local Data Transfer Between MRI and CT Scan Sets
Further Information
Publication History
Publication Date:
18 March 2008 (online)

Abstract
A comparison of the spatial position of distinct locations within cranial MRI and CT scan sets can easily be done with a simple algorithm designed as a computer program. After determination of a basic system formed by the coordinates of anatomical landmarks in CT and MRI, arbitrary points can be identified on one scan set and transferred quantitatively to the other. Pros and cons of the method are discussed and opposed to the properties of specifically designed image processing systems.
Key words
Localization - MRI/CT Matching Techniques - Preoperative Planning