Atraumatic Suction Tip for Microneurosurgery - Clinical Experience
Publication History
Publication Date:
22 January 2008 (online)
Abstract
Our two-year experience with a new atraumatic tip for the neurosurgical suction tube is described. During microneurosurgical procedures the tip reduces injury to fragile vital brain structures and protects them from being aspirated into the suction tube. The perforated membrane of the appended suction tip does not impede evacuation of blood in any situation and can be easily cleaned off without demounting. The device can be immediately attached to the tube and disconnected. The neurosurgeon need not concentrate on its use, in contrast to those systems with active suction pressure control. The atraumatic suction tip is available in several sizes to fit different callibers of suction tubes.
Key words
neurosurgical suction - atraumatic suction tip
References
- 1 Bleasel KF, Frost RB. A new neurosurgical irrigating sucking cutter. Technical note. J Neurosurg. 1986; 65 120-121
- 2 Bleasel K, Harrison J. Irrigating sucker dissector. J Neurosurg. 1980; 52 736-738
- 3 Day JD, Fukushima T. Two simple devices for microneurosurgery: automatic drip irrigating needle and a suction retractor. Neurosurgery. 1993; 32 867-868
- 4 Johnson JP, Becker DP. A continuous microneurosurgical irrigation and suction system: technical note. Neurosurgery. 1996; 39 409-411
- 5 Lüdecke DK, Treige W. Pressure-irrigation-suction system. Technical note. Acta Neurochir (Wien). 1982; 66 123-126
- 6 Miyake H, Tsuji M, Hiramoto N, Ukita T, Ohmura T. Development of a new irrigation sucker for microneurosurgery-technical note. Neurol Med Chir (Tokyo). 1989; 44 442-445
- 7 Papadopoulos SM, MacGillicuddy JE. A simple device for controlling suction force in neurosurgical operations. Neurosurgery. 1989; 25 662-663
- 8 Menovsky T, De Vries J. Atraumatic suction tip for microsurgery: technical note. Microsurgery. 2004; 24 302-303
- 9 Gusmao S. A new device with pressure regulation for microsurgical suction: technical note. Surg Neurol. 2005; 63 36-38
- 10 Sakatani K, Zuo H. Continuous suction surgical cottonoid for microneurosurgery. Neurol Res. 1998; 20 564-566
- 11 Okada Y, Kawamata T, Chernov MF, Hori T. Scaled suction for microneurosurgery: technical note. Neurosurgery;. 2005; 57 413
Correspondence
Prof. Z. Mariak
Department of Neurosurgery
Medical University of Bialystok
M.C. Sklodowskiej 24a Str.
15-276 Bialystok
Poland
Phone: +48/85/746 82 21
Fax: +48/85/746 86 26
Email: zmariak@amb.edu.pl