Semin intervent Radiol 2007; 24(3): 341-345
DOI: 10.1055/s-2007-985748
Copyright © 2007 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA.

Portal Vein Pseudoaneurysm with Portoenteric Fistula: An Unusual Cause for Massive Gastrointestinal Hemorrhage

Charles T. Burke1 , Jin Park1
  • 1Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
Further Information

Publication History

Publication Date:
03 September 2007 (online)

ABSTRACT

Pancreaticoduodenectomy (Whipple's procedure) is a commonly performed procedure for the treatment of pancreatic malignancies. Postoperative bleeding from adjacent arteries is a well-established complication of this procedure. This article describes an unusual case of massive gastrointestinal bleeding following pancreaticoduodenectomy due to the development of a portal vein pseudoaneurysm with a portoenteric fistula. The diagnosis was confirmed with multidetector computed tomography angiography; the different endovascular treatment options are discussed.

REFERENCES

  • 1 Longstreth G F. Epidemiology and outcome of patients hospitalized with acute lower gastrointestinal hemorrhage: a population-based study.  Am J Gastroenterol. 1997;  92 419-424
  • 2 Browder W, Cerise E J, Litwin M S. Impact of emergency angiography in massive lower gastrointestinal bleeding.  Ann Surg. 1986;  204 530-536
  • 3 Schmidt C M, Powell E S, Constatntin T Y et al.. Pancreaticoduodenectomy: a 20-year experience in 516 patients.  Arch Surg. 2004;  139 718-727
  • 4 Balachandran P, Sikora S S, Raghavendra Rao R V et al.. Haemorrhagic complications of pancreaticoduodenctomy.  ANZ J Surg. 2004;  74 945-950
  • 5 Koukoutsis I, Bellagamba R, Morris-Stiff G et al.. Haemorrhage following pancreaticoduodenectomy: risk factors and the importance of sentinel bleed.  Dig Surg. 2006;  23 224-228
  • 6 Rumstadt B, Schwab M, Korth P et al.. Hemorrhage after pancreatoduodenectomy.  Ann Surg. 1998;  227 236-241
  • 7 Gervais D A, Fernandez-del-Castillo C, O'Neill M J et al.. Complications after pancreaticoduodenectomy: imaging and imaging-guided interventional procedures.  Radiographics. 2001;  21 673-690
  • 8 Povoski S P, Shamma'a J M. Fistula involving portal vein and duodenum at the site of a duodenal ulcer in a patient after previous extrahepatic bile duct resection and brachytherapy.  Dig Surg. 2003;  20 53-55
  • 9 Soares M A, Wanless I R, Ambus U et al.. Fistula between duodenum and portal vein caused by peptic ulcer disease and complicated by hemorrhage and portal vein thrombosis.  Am J Gastroenterol. 1996;  91 1462-1463
  • 10 Frauenfelder T, Wildermuth S, Marincek B et al.. Nontraumatic emergent abdominal vascular conditions: advantages of multi-detector row CT and three-dimensional imaging.  Radiographics. 2004;  24 481-496
  • 11 Kuhle W G, Shieman R G. The sensitivity of helical CT in detecting active colonic hemorrhage.  J Vasc Interv Radiol. 2000;  11(suppl) 208
  • 12 Miller F H, Hwang C M. An initial experience using helical CT imaging to detect obscure gastrointestinal bleeding.  Clin Imaging. 2004;  28 245-251
  • 13 Sohn T A, Yeo C J, Cameron J L et al.. Pancreaticoduodenectomy: role of interventional radiologists in managing patients and complications.  J Gastrointest Surg. 2003;  7 209-219
  • 14 Jin B, Sun Y, Li Y-Q et al.. Extrahepatic portal vein aneurysm: two case reports of surgical intervention.  World J Gastroenterol. 2005;  11 2206-2209
  • 15 Luo H-F, Wang H-J, Li B et al.. Diagnosis and management of extrahepatic portal vein aneurysm: a case report.  Hepatobiliary Pancreat Dis Int. 2006;  5 311-313
  • 16 White R, Krajcer Z, Johnson M et al.. Results of a multicenter trial for the treatment of traumatic vascular injury with a covered stent.  J Trauma. 2006;  60 1189-1195
  • 17 Peynircioglu B, Cwikiel W. Utility of stent-grafts in treatment of porto-biliary fistula.  Cardiovasc Intervent Radiol. 2006;  29 1156-1159
  • 18 Charon J-P, Alaeddin F H, Pimpalwar S A et al.. Results of a retrospective multicenter trial of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation.  J Vasc Interv Radiol. 2004;  15 1219-1230
  • 19 Ishii S, Sonomura T, Yamada K et al.. Optimal covering material for stent-grafts placed in the portal vein in a canine model.  Cardiovasc Intervent Radiol. 2005;  28 624-631
  • 20 Harvey J, Dardik H, Impeduglia T et al.. Endovascular management of hepatic artery pseudoaneurysm hemorrhage complicating pancreaticoduodenectomy.  J Vasc Surg. 2006;  43 613-617
  • 21 Burks Jr J A, Faries P L, Gravereaux E C et al.. Endovascular repair of bleeding aortoenteric fistulas: a 5-year experience.  J Vasc Surg. 2001;  34 1055-1059
  • 22 Kar B, Dougherty K, Reul G J et al.. Aortic stent-graft infection due to a presumed aortoenteric fistula.  J Endovasc Ther. 2002;  9 901-906
  • 23 Kotsis T, Lioupis C, Tzanis A et al.. Endovascular repair of a bleeding secondary aortoenteric fistula with acute leg ischemia: a case report and review of the literature.  J Vasc Interv Radiol. 2006;  17 563-567
  • 24 Malina M, Veith F, Ivancev K et al.. Balloon occlusion of the aorta during endovascular repair of ruptured abdominal aortic aneurysm.  J Endovasc Ther. 2005;  12 556-559
  • 25 Weeks S M, Stroud T H, Sandhu J et al.. Temporary balloon occlusion of the internal iliac arteries for control of hemorrhage during cesarean hysterectomy in a patient with placenta previa and placenta increta.  J Vasc Interv Radiol. 2000;  11 622-624
  • 26 Miura F, Takada T, Ochiai T et al.. Aortic occlusion balloon catheter technique is useful for uncontrollable massive intraabdominal bleeding after hepato-pancreato-biliary surgery.  J Gastrointest Surg. 2006;  10 519-522

Charles T BurkeM.D. 

Department of Radiology, CB#7510, 101 Manning Drive

Chapel Hill, NC 27599-7510

    >