A New Portable Device for Assessing Locomotor Performance

M. L'Hermette1 , 2 , X. Savatier2 , 3 , L. Baudry1 , C. Tourny-Chollet1 , 2 , F. Dujardin2
  • 1CETAPS, EA 3832, University of Rouen, Rouen, France
  • 2GRHAL, University of Rouen, Rouen, France
  • 3Automatique Industrielle, ESIGELEC, Rouen, France
Further Information

Publication History

accepted after revision February 26, 2007

Publication Date:
18 September 2007 (online)

Abstract

We investigated the validity of a new portable system and the feasibility of the method for gait analysis as the assessment of gait has clinical relevance in the study of locomotor pathologies. This system is composed of a data logger, triaxial accelerometers, and software. Measurements of the pelvis kinematics during gait were performed on five hip osteoarthritic subjects and 15 healthy subjects using the portable system and a reference system (Vicon™). The healthy subjects were studied in conditions of normal gait and gait altered by a heelpiece. The studied variables were the vertical amplitude of the sacrum, the time of gait cycle and the vertical trajectories of the spines. The new system corresponded with the reference system for the studied variables. The small differences between the two systems in the vertical amplitude of the sacrum (0.53 ± 6.39 mm), time of the gait cycle (0.002 ± 0.05 s), and the vertical trajectories of the spine (coefficient correlation of 0.06 ± 0.05) confirmed the validity of the portable system data. The results showed a distortion of the pelvis trajectory when the gait was impaired. The portable system provides an objective method to discriminate normal from limping gait and is easy to use outside of the laboratory.

References

  • 1 Aminian K, Trevisan C, Najafi B, Dejnabadi H, Frigo C, Pavan E, Telonio A, Cerati F, Mrinoni E C, Robert P H, Leyvraz P F. Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement.  Gait Posture. 2004;  20 102-107
  • 2 Antonsson E, Mann R. The frequency content of gait.  J Biomech. 1985;  8 39-47
  • 3 Belli A, Kyröläinen H, Komi P V. Moment and power of lower limb joints in running.  Int J Sports Med. 2002;  23 136-141
  • 4 Bland J M, Altman D. Statistical methods for assessing agreement between measurements.  Biochim Clin. 1987;  11 399-404
  • 5 Bouten C V, Koekkoek K T, Verduin M, Kodde R, Janssen J. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity.  IEEE Trans Biomed Eng. 1997;  44 136-147
  • 6 Detrembleur C, van den Hecke A, Dierick F. Motion of the body centre of gravity as a summary indicator of the mechanics of human pathological gait.  Gait Posture. 2000;  12 243-250
  • 7 Dujardin F, Aucouturier T, Bocquet G, Duparc F, Weber J, Thomine J M. Cinématique de la coxo-fémorale saine et arthrosique durant la marche.  Rev Chir Orth. 1998;  84 689-699
  • 8 Hamill J, Bates B, Knutzen K. Ground reaction force symmetry during walking and running.  Med Sci Sports Exerc. 1983;  15 170
  • 9 Hirasawa Y. Left leg supporting human straight (bipedal) standing.  Saiensu. 1981;  6 32-44
  • 10 Hopkins W. Bias in Bland-Altman but not regression validity analysis.  Sportsci. 2004;  8 42-46
  • 11 Howell D. Statistical Methods for Psychology. 5th edn. Duxbury; Thomson Learning Inc. 2002 277 384-386
  • 12 Kang T, He J, Tillery S. Determining natural arm configuration along a reaching trajectory.  Exp Brain Res. 2005;  167 352-361
  • 13 Kitazaki S, Griffin M J. A data correction method for surface measurement of vibration on the human body.  J Biomech. 1995;  28 885-890
  • 14 L'Hermette M, Polle G, Tourny-Chollet C, Dujardin F. Hip passive range of motion and frequency of radiographic hip osteoarthritis in former elite handball players.  Br J Sports Med. 2006;  40 45-49
  • 15 L'Hermette M, Tourny-Chollet C, Polle G, Dujardin F. Articular cartilage, degenerative progress, and repair: current progress.  Int J Sports Med. 2006;  27 738-744
  • 16 Leroy D, Polin D, Tourny-Chollet D, Weber J. Spatial and temporal gait variable differences between basketball, swimming and soccer players.  Int J Sports Med. 2000;  21 158-162
  • 17 Mathie M, Coster A, Lovell N, Celler B. Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement.  Physiol Meas. 2004;  25 R1-R20
  • 18 Mayagoitia R E, Anand V N, Veltink P H. Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis system.  J Biomech. 2002;  35 537-542
  • 19 Moe-Nilssen R, Helbostad J L. Estimation of gait cycle characteristics by trunk accelerometry.  J Biomech. 2004;  37 121-126
  • 20 Murray M, Drought B, Ross C. Walking patterns of normal men.  J Bone Joint Surg. 1964;  46-A 335-360
  • 21 Neptune R, Wright I, van den Bogert A. Muscle coordination and function during cutting movements.  Med Sci Sports Exerc. 1999;  31 294-302
  • 22 Ounpuu S, Winter D. Bilateral analysis of the lower limbs during walking in normal individuals.  Proceedings NACOB. 1986;  2 265-266
  • 23 Sadeghi H, Allard P, Duhaime M. Functional gait asymmetry in able-bodied subjects.  Hum Mov Sci. 1997;  16 243-258
  • 24 Sadeghi H, Allard P, Prince F, Labelle H. Symmetry and limb dominance in able-bodied gait: a review.  Gait Posture. 2000;  12 34-45
  • 25 van den Bogert A J, Read L, Nigg B M. An analysis of hip joint loading during walking, running, and skiing.  Med Sci Sports Exerc. 1999;  31 131-142
  • 26 Watelain E, Dujardin F, Babier F, Dubois D, Allard P. Pelvic and lower limb compensatory actions of subjects in an early stage of hip osteoarthritis.  Arch Phys Med Rehab. 2001;  82 1705-1711
  • 27 Zappa B, Legnani G, van den Bogert A, Adamini R. On the number and placement of accelerometers for angular velocity and acceleration determination.  J Dyn Syst Meas Control. 2001;  123 152-154

Dr. Maxime L'Hermette

University of Rouen
CETAPS, EA 3832

76821 Rouen

France

Email: maxime.lhermette@univ-rouen.fr

    >