Int J Sports Med 2008; 29(3): 199-205
DOI: 10.1055/s-2007-965066
Training & Testing

© Georg Thieme Verlag KG Stuttgart · New York

Fatigue Responses in Exercise under Control of V·O2

P.-M. Lepretre1 , P. Lopes2 , J.-P. Koralsztein3 , V. Billat3
  • 1Laboratory of Biomechanics and Exercice Physiology, Department of Sports Sciences, Insitut National des Sports et de l'Education Physique, Paris, France
  • 2Department of Sports and Physical Activities, Univeristy of Evry - Val d'Essonne, Evry, France
  • 3Laboratory of Exercise Physiology, Department of Sports and Physical Activities of Evry, Evry, France
Further Information

Publication History

accepted after revision January 18, 2007

Publication Date:
18 September 2007 (online)

Abstract

To examine the fatigue response during an exhaustive heavy exercise performed under control of oxygen uptake (SS@V·O2Δ50) or power output (SS@pΔ50), eleven trained male subjects performed an incremental test to determine the peak of the oxygen uptake value (V·O2peak) and lactate threshold and two exhaustive steady-state cycling exercises at the intermediate value between the lactate threshold and V·O2peak (SS@V·O2Δ50 and SS@pΔ50). The control of V·O2 induced an oscillation of the power output, which lowered the average power output (276 ± 47 vs. 315 ± 40 W, p = 0.004) and cancelled the slow component of oxygen kinetics. However, all subjects reached maximal cardiac output (CO) and heart rate (HR) values which were sustained almost two times longer in SS@V·O2Δ50 compared to SS@pΔ50 (979 ± 854 vs. 475 ± 236 s, p = 0.046 for CO and 1050 ± 890 vs. 513 ± 288 s, p = 0.037 for HR). Furthermore, SS@pΔ50 elicited V·O2peak but not SS@V·O2Δ50 (4963 ± 434 vs. 4723 ± 460 mL · min-1, p = 0.026). Finally, the time spent at the maximal CO and HR values is correlated with time to exhaustion at V·O2Δ50. In conclusion, the cause of fatigue does not seem to have the same origin during exhaustive supra-lactate threshold exercise under control of V·O2 (V·O2Δ50) compared to constant power output (pΔ50), while both elicit the maximal HR and CO values.

References

  • 1 Aunola S, Rusko H. Reproducibility of aerobic and anaerobic threshold on 20 - 50 year old men.  Eur J Appl Physiol. 1986;  53 260-266
  • 2 Barstow T J. Characterization of V·O2 kinetics during heavy exercise.  Med Sci Sports Exerc. 1994;  26 2099-2106
  • 3 Billat V L, Blondel N, Berthoin S. Determination of the velocity associated with the longest time to exhaustion at maximal oxygen uptake.  Eur J Appl Physiol. 1999;  80 159-161
  • 4 Billat V L, Koralsztein J P. Significance of the velocity at V·O2max and time to exhaustion at this velocity.  Sports Med. 1996;  22 90-108
  • 5 Billat V L, Morton R H, Blondel N, Berthoin S, Bocquet V, Koralsztein J P, Barstow T J. Oxygen kinetics and modelling of time to exhaustion whilst running at various velocities at maximal oxygen uptake.  Eur J Appl Physiol. 2000;  82 178-187
  • 6 Billat V L, Richard R, Binsse V M, Koralsztein J P, Haouzi P. The V·O2 slow component for a severe exercise depends on type of exercise and its not correlated with time to fatigue.  J Appl Physiol. 1998;  85 2118-2124
  • 7 Billat V L, Richard R, Lonsdorfer E, Lonsdorfer J. Stroke volume increases in an all-out severe cycling exercise in moderate trained subjects.  Med Sci Sports Exerc. 2001;  33 S96
  • 8 Borrani F, Candau R, Millet G Y, Perrey S, Fuchslocher J, Rouillon J D. Is the V·O2 slow component dependent on progressive recruitment of fast-twitch fibers in trained runners?.  J Appl Physiol. 2001;  90 2212-2220
  • 9 Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Manmosser M, Mettauer B, Geny B, Lonsdorfer J. A new impedance cardiograph device for non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method.  Eur J Appl Physiol. 2000;  82 313-320
  • 10 Coyle E F. Cardiovascular drift during prolonged exercise and the effects of dehydration.  Int J Sports Med. 1998;  19 (Suppl 2) S121-S124
  • 11 Dampney R A, Coleman M J, Fontes M A, Hirooka Y, Horiuchi J, Li Y W, Polson J W, Potts P D, Tagawa T. Central mechanisms underlying short- and long-term regulation of the cardiovascular system.  Clin Exp Pharmacol Physiol. 2002;  29 261-268
  • 12 Delp M D. Control of skeletal muscle perfusion at the onset of dynamic exercise.  Med Sci Sports Exerc. 1999;  31 1011-1018
  • 13 Durnin J V, Womersley J. Body fat assessed from total body density and its estimation from skin-fold thickness: measurements on 481 men and women aged from 16 to 72 years.  Br J Nutr. 1974;  32 77-97
  • 14 Gaesser G A, Poole D. The slow component of oxygen uptake kinetics in humans.  Exerc Sport Sci Rev. 1996;  24 35-70
  • 15 Gonzalez-Alonso J, Mora-Rodriguez R, Coyle E F. Stroke volume during exercise: interaction of environment and hydration.  Am J Physiol. 2000;  278 H321-H330
  • 16 Goodman J M, McLaughlin P R, Liu P P. Left ventricular performance during prolonged exercise: absence of systolic dysfunction.  Clin Sci (Lond). 2001;  10 529-537
  • 17 Grassi B. Skeletal muscle V·O2 on-kinetics: set by O2 delivery or by O2 utilization? New insights into an old issue.  Med Sci Sports Exerc. 2000;  32 108-116
  • 18 Jensen-Urstad M, Bouvier F, Nejat M, Saltin B, Brodin L A. Left ventricular function in endurance runners during exercise.  Acta Physiol Scand. 1998;  164 167-172
  • 19 Koppo K, Bouckaert J, Jones A M. Oxygen uptake kinetics during high-intensity arm and leg exercise.  Respir Physiol Neurobiol. 2002;  133 241-250
  • 20 Krip B, Gledhill N, Jamnik V, Warburton D. Effect of alterations in blood volume on cardiac function during maximal exercise.  Med Sci Sports Exerc. 1997;  29 1469-1476
  • 21 Kuipers H, Verstappen F T, Keizer H A, Geurten P, van Kranenburg G. Variability of aerobic performance in the laboratory and its physiological correlates.  Int J Sports Med. 1985;  6 197-201
  • 22 Lepretre P M, Koralsztein J P, Billat V L. Effect of exercise intensity on relationship between V·O2max and cardiac output.  Med Sci Sports Exerc. 2004;  36 1357-1363
  • 23 Maiolo C, Melchiorri G, Lacopino L, Masala S, de Lorenzo A. Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer.  Br J Sports Med. 2003;  37 445-446
  • 24 Nassis G P, Geladas N D. Cardiac output decline in prolonged dynamic exercise is affected by the exercise mode.  Pflügers Arch. 2002;  445 398-404
  • 25 Pyne D B, Boston T, Martin D T, Logan A. Evaluation of the Lactate Pro blood lactate analyser.  Eur J Appl Physiol. 2000;  82 112-116
  • 26 Whipp B J, Ozyener F. The kinetics of exertional oxygen uptake: assumptions and inferences.  Sport Med. 1998;  51 139-149
  • 27 Xu F, Rhodes E C. Oxygen uptake kinetics during exercise.  Sports Med. 1999;  27 313-327

Dr. PhD Pierre-Marie Leprêtre

Laboratoire de Biomécanique et de Physiologie
Département des Sciences du Sport
Insitut National du Sport et de l'Education Physique

11, avenue du Tremblay

75015 Paris

France

Fax: + 33 141 74 45 35

Email: lepretre.pierre-marie@wanadoo.fr

    >