This is a report of a patient with subtotal obstruction of a Häring endoprosthesis
due to the continuous growth of tumor tissue through the wall of the tube. Using a
diathermic wire loop the obstructing tumor tissue was removed, and the esophageal
passage cleared.
Esophageal prosthesis - Complications