Endoscopy 2005; 37(4): 405-406
DOI: 10.1055/s-2005-861099
Unusual Cases and Technical Notes
© Georg Thieme Verlag KG Stuttgart · New York

Endoscopic Resection of a Large Pedunculated Colonic Polyp Using an Insulated-Tip Diathermy Knife

K.  Akahoshi1 , M.  Kubokawa1 , T.  Fujimaru1 , M.  Matsumoto1 , M.  Kimura1 , H.  Akiho1 , Y.  Sumida1 , M.  Oya2
  • 1Department of Gastroenterology, Aso Iizuka Hospital, Iizuka, Japan
  • 2Department of Pathology, Aso Iizuka Hospital, Iizuka, Japan
Further Information

Publication History

Publication Date:
16 May 2006 (online)

A large pedunculated polyp was discovered incidentally during colonoscopic examination in a 70-year-old Japanese woman. She had undergone the examination after a positive fecal occult blood test. The polyp was located in the sigmoid colon and had a long stalk and a large head. Its removal was considered to be technically demanding because the head of the polyp nearly occluded the lumen of the colon, making it difficult to maneuver a snare over the polyp. The stalk of the polyp was fully visible, however, and we attempted endoscopic resection using an insulated-tip diathermy knife (KD-610L; Olympus, Tokyo, Japan) (Figure [1]). First, we applied a long clip (HX-600 - 090L; Olympus) to the base of the stalk, close to the colonic wall, in order to prevent polypectomy-associated bleeding. The polyp stalk was then cut about 8 mm above the clip using the insulated-tip diathermy knife (Figure [2]). Pure cutting current was used. No hemorrhage, perforation, or other complication occurred. Histological evaluation of the resection specimen revealed a serrated adenoma.

Figure 1 Schematic showing endoscopic resection of a polyp using an insulated-tip diathermy knife. a A long metal clip is opened and applied to the stalk of the polyp, close to the colon wall. b The clip clamps the stalk. c The stalk above the clip is cut with an insulated-tip diathermy knife (IT). d The lesion is removed from.

Figure 2 Endoscopic view of the resection of a colorectal polyp using an insulated-tip diathermy knife. a The knife (IT) is used to cut the stalk (St) 8 mm above the clip (C). b The polyp is removed without bleeding.

It is often difficult to remove large pedunculated colorectal polyps by endoscopic polypectomy using standard snare techniques [1] [2]. Our approach was to perform an endoscopic resection using an insulated-tip diathermy knife which can be passed through the endoscope’s ordinary working channel. This knife was developed in Japan for endoscopic mucosal resection of early gastric cancer [3] [4]. It has a ceramic ball at its tip which prevents electrosurgical perforation by the needle-knife tip. Using this knife, it was safe and easy to cut the stalk of the polyp. Clipping the basal side of the stalk prior to cutting was vital for preventing polypectomy-induced bleeding. To our knowledge, this is the first report of endoscopic polypectomy using an insulated-tip diathermy knife. We believe this technique has the potential to become the method of choice for removal of pedunculated colorectal polyps when procedures involving snaring of the polyp head are not feasible.

Endoscopy_UCTN_Code_TTT_1AQ_2AD

References

  • 1 Akahoshi K, Kojima H, Fujimaru T. et al . Grasping forceps-assisted endoscopic resection of large pedunculated gastrointestinal polypoid lesions.  Gastrointest Endosc. 1999;  50 95-98
  • 2 Cipolletta L, Bianco M A, Rotondano G. et al . Endoclip-assisted resection of large pedunculated colon polyps.  Gastrointest Endosc. 1999;  50 405-406
  • 3 Ono H, Kondo H, Gotoda T. et al . Endoscopic mucosal resection for treatment of early gastric cancer.  Gut. 2001;  48 225-229
  • 4 Ohkuwa M, Hosokawa K, Boku N. et al . New endoscopic treatment for intramucosal gastric tumors using an insulated-tip diathermic knife.  Endoscopy. 2001;  33 221-226