Minim Invasive Neurosurg 2005; 48(2): 73-76
DOI: 10.1055/s-2004-830224
Original Article
© Georg Thieme Verlag Stuttgart · New York

Integrated Neuronavigation System with Intraoperative Image Updating

E.  Samset1 , J.  O.  Høgetveit2 , G.  T.  Cate1 , H.  Hirschberg1, 3
  • 1The Interventional Centre, Rikshospitalet, University Hospital, Oslo, Norway
  • 2Department of Clinical Engineering, Rikshospitalet, University Hospital, Oslo, Norway
  • 3Department of Neurosugery, Rikshospitalet, University Hospital, Oslo, Norway
Further Information

Publication History

Publication Date:
19 May 2005 (online)

Abstract

Objective: Recently, MRI has entered the field of image-guided surgery as a new intraoperative imaging modality. In spite of its obvious benefits, this type of iMRI scanner has some drawbacks that have limited its utilization. The goal of the work presented here was to overcome some of these disadvantages. Methods: A system that allows intraoperative images to be acquired during surgery and have the ability to conduct surgery outside the constraints of the narrow gap of the open magnet was implemented. Ability to conduct tasks inside the scanner with real-time image guidance was also maintained. The system allowed navigation with neuronavigation tools both inside the gap of an open magnet and outside the magnet, utilizing two different optical camera-sets and a dynamic reference frame. Automatic patient registration was implemented. Results: The average difference between tracking position measured outside and inside the magnet was 0.8 ± 0.1 mm. Conclusion: In the work presented in this note we have introduced a dynamic reference frame to compensate for transport of the patient to a location outside the scanner employing a second camera set. The integrated system showed adequate accuracy.

References

  • 1 Suess O, Kombos T, Suess S, Stendel R, Pietilae T, Brock M. The influence of intraoperative brain shift on continuous cortical stimulation during surgery in the motor cortex - An illustrative case report.  Acta Neurochirurgica. 2001;  143 621-623
  • 2 Black P M, Moriarty T, Alexander 3rd E, Stieg P, Woodard E J, Gleason P L, Martin C H, Kikinis R, Schwartz R B, Jolesz F A. Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications.  Neurosurgery. 1997;  41 831-842 discussion: 842-845
  • 3 Wirtz C R, Tronnier V M, Bonsanto M M, Knauth M, Staubert A, Albert F K, Kunze S. Image-guided neurosurgery with Intraoperative MRI: Update of frameless stereotaxy and radicality control.  Stereotactic & FunctionaI Neurosurgery. 1999;  68 39-43
  • 4 Schenck J F, Jolesz F A, Roemer P B, Cline H E, Lorensen W E, Kikinis R, Silverman S G, Hardy C J, Barber W D, Laskaris E T, Dorri B, Newman R W, Holley C E, Collick B D, Dietz D P, Mack D C, Ainslie M D, Jaskolski P L, Figueira M R, Lehn J C, Souza S P, Dumoulin C L, Darrow R D, St Peters R L, Rohling K W, Watkins R D, Eisner D R, Blumenfeld S M, Vosburgh K G. Superconducting open-configuration MR imaging system for image-guided therapy.  Interventional Radiology. 1995;  195 805-814
  • 5 Gering D T, Nabavi A, Kikinis R, Hata N, O'Donnell L J, Grimson W E, Jolesz F A, Black P M, Wells III W M. An integrated visualization system for surgical planning and guidance using image fusion and an open MR.  J Magn Reson Imaging. 2001;  13 967-975
  • 6 Hata N, Jinzaki M, Kacher D, Cormak R, Gering D, Nabavi A, Silverman S G, D'Amico A V, Kikinis R, Jolesz F A, Tempany C M. MR imaging-guided prostate biopsy with surgical navigation software: Device validation and feasibility.  Radiology. 2001;  220 263-268
  • 7 Samset E, Hirschberg H. Neuronavigation in intra-operative MRI.  Computer-Aided Surgery. 1999;  4 200-207
  • 8 Hirschberg H, Samset E. Intraoperative image-directed dye marking of tumor margins.  Minim Invas Neurosurg. 1999;  42 123-127
  • 9 Hirschberg H. Implementation of a stereotactic microscope using an optically coupled tracking system.  Stereotactic & Functional Neurosurgery. 1996;  66 96-101
  • 10 Hirschberg H, Kirkeby O J. Interactive image directed neurosurgery: Patient registration employing the Laitinen stereo-adapter.  Minim Invas Neurosurg. 1996;  39 105-107
  • 11 Hirschberg H, Unsgaard G. Incorporation of ultrasonic imaging in an optically coupled frameless stereotactic system.  Acta Neurochirurgica - Supplementum. 1997;  68 75-80
  • 12 Gronningsaeter A, Kleven A, Ommedal S, Aarseth T E, Lie T, Lindseth F, Lango T, Unsgard G. SonoWand, an ultrasound-based neuronavigation system.  Neurosurgery. 2000;  47 1373-1379
  • 13 Kansy K, Wisskirchen P, Behrens U, Berlage T, Grunst G, Jahnke M, Ratering R, Schwarzmaier H J, Ulrich F. LOCALITE - a frameless neuronavigation system for interventional magnetic resonance imaging systems.  MICCAI. 1999;  1679 832-841 [Abstract]
  • 14 Bernstein M, Al Anazi A R, Kucharczyk W, Manninen P, Bronskill M, Henkelman M. Brain tumor surgery with the Toronto open magnetic resonance imaging system: Preliminary results for 36 patients and analysis of advantages, disadvantages, and future prospects.  Neurosurgery. 2000;  47 1946; discussion: 907-909
  • 15 Wirtz C R, Bonsanto M M, Knauth M, Tronnier V M, Albert F K, Staubert A, Kunze S. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: Method and preliminary experience.  Computer-Aided Surgery. 1997;  2 172-179
  • 16 McInerney J, Roberts D W. Frameless stereotaxy of the brain.  Mt Sinai J Med. 2000;  67 300-310

Eigil Samset, Ph. D. 

The Interventional Centre · Rikshospitalet University Hospital

0027 Oslo

Norway

Phone: +47-230-70111

Fax: +47-230-70110

Email: eigil.samset@rikshospitalet.no

    >