Subscribe to RSS
DOI: 10.1055/s-2002-20204
Fatal hemorrhage following perforation of the aorta by a barb of the Gianturco-Rösch esophageal stent
Tödliche Blutung durch Perforation des Fixierungshäkchens eines ösophagealen Gianturco-Rösch-Stents in der AortaPublication History
Publication Date:
20 February 2002 (online)

Abstract
Self-expanding metal stents are an established option in the palliative treatment of malignant stenoses of the esophagus. Herein, we report on a 60-year-old man with a recurrent stenosis that developed 2 months after radiochemotherapy for a squamous cell carcinoma in the middle part of the esophagus. To relieve progressive dysphagia, a Gianturco-Rösch stent (Cook-Z stent, 10 cm, PE-covered, manufactured by William Cook Europe) was implanted. Six weeks later, precipitous massive hemoptysis leading to the collapse and death of the patient occurred. Autopsy showed that a barb in the middle of the stent had perforated the aortic arch, resulting in massive bleeding into the gastrointestinal tract, and aspiration. Although hemorrhage and esophageal perforation are known late complications of all types of metal stents, our case is the first description of a perforation involving a fixation barb. These barbs are a particular feature of the European version of the Cook-Z stent, and are intended to prevent stent migration. In future, any hemorrhage observed after stent implantation should prompt a search for perforation by a barb (autopsy!). If necessary, the European version of the Gianturco Z stent should be modified.
Zusammenfassung
Selbst expandierende Metallstents sind eine etablierte Therapieoption in der palliativen Therapie maligner Ösophagusstenosen. Wir berichten über einen 60-jährigen Patienten mit einem Stenoserezidiv 2 Monate nach Radiochemotherapie eines Plattenepithelkarzinoms im mittleren Ösophagus. Bei zunehmender Dysphagie wurde deshalb ein Gianturco-Rösch-Stent implantiert (Cook-Z-Stent 10 cm, PE-ummantelt der Fa. William Cook Europe). Sechs Wochen später kam es schlagartig zu massiver Hämoptoe mit Kollaps und Todesfolge. Die Obduktion zeigte eine Perforation eines Fixationshäkchens im mittleren Stentbereich durch die Wand des Ösophagus in den anliegenden Aortenbogen mit massiver gastrointestinaler Blutung und Aspiration. Blutungen und Ösophagusperforationen sind als Spätkomplikation bei allen Metallstents bekannt, unser Fall beschreibt aber erstmalig eine Perforation durch die äußeren Fixationshäkchen. Diese Widerhaken (”barbs”) sind eine Besonderheit der europäischen Variante des Cook-Z-Stents und sollen eine Stentmigration verhindern. Bei Blutungen nach Stentimplantationen sollte in Zukunft gezielt nach einer Perforation durch Fixationshäkchen gesucht werden (Obduktion!), ggf. ist eine technische Modifikation der europäischen Stentvariante erforderlich.
Key words
Metal Stent - Gianturco - Esophagus - Perforation - Hemorrhage - Complication - Barb - Aortoesophageal Fistula
Schlüsselwörter
Metallstent - Gianturco - Ösophagus - Perforation - Blutung - Komplikation - Fixationshaken - aortoösophagiale Fistel
References
- 1 Neuhaus H, Schumacher B. Einsatz von Metallstents in der Gastroenterologie. Z Gastroenterol. 1998; 36 121-134
- 2 May A, Hahn E G, Ell C. Self-expanding metal stents for palliation of malignant obstruction in the upper gastrointestinal tract. Comparative assessment of three stent types implemented in 96 implantations. J Clin Gastroenterol. 1996; 22 261-266
- 3 Ell C, May A. Self-expanding metal stents for palliation of stenosing tumors of the esophagus and cardia: A critical review. Endoscopy. 1997; 29 392-398
- 4 Inoue H, Tani M, Nagai K. et al . Treatment of esophageal and gastric tumors. Endoscopy. 1999; 31 47-55
- 5 Tytgat G N, den Hartog Jäger F CA, Haverkamp H J. Positioning of a plastic prosthesis under fiberendoscopic control in the palliative treatment of cardioesophageal cancer. Endoscopy. 1976; 8 180-185
- 6 Schumacher B, Lubke H, Frieling T, Haussinger D, Niederau C. Palliative treatment of malignant esophageal stenosis: Experience with plastic versus metal stents. Hepatogastroenterology. 1998; 45 755-760
- 7 Bohnacker S, Thonke F, Hinner M. et al . Improved endoscopic stenting for malignant dysphagia using Tygon plastic prostheses. Endoscopy. 1998; 30 524-531
- 8 Bartelsman J F, Bruno M J, Jensema A J. et al . Palliation of patients with esophagogastric neoplasms by insertion of a covered expandable modified gianturco-Z endoprosthesis: Experiences in 153 patients. Gastrointest Endosc. 2000; 51 134-138
- 9 Ell C, May A, Hahn E G. Selbstexpandierende Metallendoprothesen zur Palliation stenosierender Tumoren im oberen Gastrointestinaltrakt. Dtsch Med Wochenschr. 1995; 120 1343-1348
- 10 Ell C, May A, Hahn E G. Gianturco-Z stents in the palliative treatment of malignant esophageal obstruction and esophagotracheal fistulas. Endoscopy. 1995; 27 495-500
- 11 Saxon R R, Barton R E, Rösch J. Complications of esophageal stenting and balloon dilatation. Semin Int Radiol. 1994; 11 276-281
- 12 Siersema P D, Hop W C, van Blankenstein M, Dees J. A new design metal stent (Flamingo stent) for palliation of malignant dysphagia: A prospective study. Gastrointest Endosc. 2000; 51 139-145
- 13 Siersema P D, Tan T G, Sutorius F F, Dees J, van Blankenstein M. Massive hemorrhage caused by a perforating Gianturco-Z stent resulting in an aortoesophageal fistula. Endoscopy. 1997; 29 416-420
- 14 Kinsman K J, DeGregorio B T, Katon R M. et al . Prior radiation and chemotherapy increase the risk of life-threatening complications after insertion of metallic stents for esophagogastric malignancy. Gastrointest Endosc. 1996; 43 196-203
- 15 Siersema P D, Hop W, Dees J, Tilanus H W, van Blankenstein M. Coated self-expanding metal stents versus latex prostheses for esophagogastic cancer with special reference to prior radiation and chemotherapy: A controlled, prospective study. Gastrointest Endosc. 1998; 47 113-120
- 16 Gabrail N Y, Harrison B R, Sunwoo Y C. Chemo-irradiation induced aortoesophageal fistula. J Surg Oncol. 1991; 48 213-215
- 17 Chowhan N M. Injurious effects of radiation on the esophagus. Am J Gastroenterol. 1990; 85 115-120
- 18 Wadsworth S J, Juniper M C, Benson M K, Gleeson F V. Fatal complication of an expandable metallic bronchial stent. Br J Radiol. 1999; 72 706-708
- 19 Lambert R. Treatment of esophagogastric tumors. Endoscopy. 2000; 32 322-330
Korrespondenzadresse
OA Dr. Klaus Dirks
Medizinische Klinik I
Klinikum Bayreuth
Preuschwitzer Straße 101
95445 Bayreuth
Fax: 0921/400-6409
Email: Klaus.Dirks@t-online.de