Vet Comp Orthop Traumatol 2025; 38(04): A1-A35
DOI: 10.1055/s-0045-1810314
PODIUM ABSTRACTS

Postoperative Complication Rates and Clinical Outcomes After Surgical Stabilization of Humeral Fractures with String-of-Pearls Plate in Dogs

L. Chang
1   Department of Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, Washington, United States
,
B. R. M. Darveshi
1   Department of Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, Washington, United States
› Institutsangaben
 

Introduction: String-of-Pearls (SOP) plate is considered advantageous for stabilizing comminuted humeral fractures as it is easily contoured, has multi-dimensional screw placement and high area moment of inertia. We hypothesize that SOP plate fixation of humeral fractures results in good long-term outcomes.

Materials and Methods: Medical records of dogs undergoing SOP plate humeral fracture repair between 2015 and 2024 were reviewed and assessed for complications and long-term outcomes.

Results: Twenty-two dogs were included with predominantly closed (21) mid-diaphyseal (6) comminuted (18) Y-T (6) fractures represented. Single (11) and double (11) plate fixation were used. Minor complications occurred in 13.6%. Major complications occurred in 41% (9) including implant failure in five dogs (screw [4] and olecranon osteotomy [1]) and implant infection in 5/6 dogs requiring explantation. Anaesthesia times and plate:screw ratios were similar in all dogs. All with infections received liposomal bupivacaine, however, only 56% (9) without infection did. Long-term outcomes were assessed (mean: 155.7 weeks [12–341 weeks]). Half (11) showed no lameness, 9% (2) mild-moderate, and 36.4% (8) experienced severe mobility impairment due to major complications.

Discussion/Conclusion: We reject the hypothesis that humeral fracture repair with SOP plate leads to good long-term outcomes. Over half experienced complications with a third of patients having severe long-term mobility impairment. A high infection rate is suspected due to preexisting soft tissue trauma and anaesthesia duration due to the complexity of the fractures. All with infections received incisional liposomal bupivacaine, raising questions about its use. Larger studies are needed to confirm these findings and compare them with other implant systems.

Acknowledgment

None.



Publikationsverlauf

Artikel online veröffentlicht:
15. Juli 2025

© 2025. Thieme. All rights reserved.

Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany