RSS-Feed abonnieren

DOI: 10.1055/s-0045-1809182
Performance Validation of Fabricated Nanomaterial-Based Biosensor for Matrix Metalloproteinase-8 Protein Detection
Autor*innen
Funding This work was funded by the National Science Research and Innovation Fund (NSRF), 2568A14212049. This work was also supported in part by the Faculty of Dentistry, Mahidol University and the Department of Chemistry, Faculty of Science and Technology, Pibulsongkram Rajabhat University.
Abstract
Objective
Matrix metalloproteinase-8 (MMP-8) is a crucial collagenase enzyme that primarily degrades type I collagen and extracellular glycoproteins, playing a significant role in the pathological processes of periodontal disease. It can serve as a biomarker for early detection and screening of the disease through advanced biosensor technology. The aim of this study was to fabricate and validate the performance of a nanomaterial-based biosensor for detecting MMP-8 protein.
Materials and Methods
The screen-printed gold electrode was modified with a thin film of 11-mercaptoundecanoic acid using the self-assembled monolayer technique. A biosensor was then created with N-hydroxysuccinimide and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide to form ester bonds, followed by the immobilization of the antibody MMP-8 and blocking of nonspecific binding. The performance characteristics of a biosensor for detecting MMP-8 concentrations, ranging from 1 to 50 ng/mL, were evaluated using electrochemical techniques with data analysis performed using the NOVA software. Enzyme-linked immunosorbent assay (ELISA) was used as a control.
Statistical Analysis
The results were expressed as mean values ± standard deviation. The coefficient of determination (R 2) was calculated based on the obtained calibration curve.
Results
Electrochemical measurements revealed that the peak current after modifying the thin film on the electrode was lower than the bare electrode. Characterization of biosensors showed an increase in response compared to the previous step. Differential pulse voltammetry measurements indicated that the peak current for MMP-8 concentrations ranging from 1 to 50 ng/mL increased proportionally with concentration. The biosensor demonstrated high sensitivity, with a correlation coefficient of R 2 = 0.953 when compared to ELISA (R 2 = 1).
Discussion and Conclusion
A biosensor utilizing nanomaterials has been successfully fabricated for the detection of the MMP-8 protein with high sensitivity. Subsequent research should prioritize the evaluation of its performance in clinical patients alongside an assessment of its specificity and stability. The objective was to advance this biosensor as a reliable diagnostic tool for the screening of periodontitis.
Keywords
biosensor - nanomaterials - matrix metalloproteinase-8 - periodontitis - point-of-care testingPublikationsverlauf
Artikel online veröffentlicht:
21. Mai 2025
© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Kinane DF. Causation and pathogenesis of periodontal disease. Periodontol 2000 2001; 25 (01) 8-20
- 2 Darveau RP. Periodontitis: a polymicrobial disruption of host homeostasis. Nat Rev Microbiol 2010; 8 (07) 481-490
- 3 Kornman KS. Mapping the pathogenesis of periodontitis: a new look. J Periodontol 2008; 79 (08) 1560-1568
- 4 Lamont RJ, Koo H, Hajishengallis G. The oral microbiota: dynamic communities and host interactions. Nat Rev Microbiol 2018; 16 (12) 745-759
- 5 Pan W, Wang Q, Chen Q. The cytokine network involved in the host immune response to periodontitis. Int J Oral Sci 2019; 11 (03) 30
- 6 de Morais EF, Pinheiro JC, Leite RB, Santos PPA, Barboza CAG, Freitas RA. Matrix metalloproteinase-8 levels in periodontal disease patients: a systematic review. J Periodontal Res 2018; 53 (02) 156-163
- 7 Luchian I, Goriuc A, Sandu D, Covasa M. The role of matrix metalloproteinases (MMP-8, MMP-9, MMP-13) in periodontal and peri-implant pathological processes. Int J Mol Sci 2022; 23 (03) 1806
- 8 Sapna G, Gokul S, Bagri-Manjrekar K. Matrix metalloproteinases and periodontal diseases. Oral Dis 2014; 20 (06) 538-550
- 9 Carra MC, Gueguen A, Thomas F. et al. Self-report assessment of severe periodontitis: periodontal screening score development. J Clin Periodontol 2018; 45 (07) 818-831
- 10 Jaumet L, Hamdi Z, Julia C. et al. Periodontitis assessed with a new screening tool and oral health-related quality of life: cross-sectional findings among general-population adults. Qual Life Res 2023; 32 (01) 259-272
- 11 Landry RG, Jean M. Periodontal Screening and Recording (PSR) index: precursors, utility and limitations in a clinical setting. Int Dent J 2002; 52 (01) 35-40
- 12 Goulão B, MacLennan GS, Ramsay CR. Have you had bleeding from your gums? Self-report to identify giNGival inflammation (The SING diagnostic accuracy and diagnostic model development study). J Clin Periodontol 2021; 48 (07) 919-928
- 13 He W, You M, Wan W, Xu F, Li F, Li A. Point-of-care periodontitis testing: biomarkers, current technologies, and perspectives. Trends Biotechnol 2018; 36 (11) 1127-1144
- 14 Chepuri T, Gooty JR, Durvasala S, Palaparthi R. Chair side diagnostic test kits in periodontics. Indian J Dent Adv 2015; 7 (01) 41-45
- 15 Izadi Borujeni S, Mayer M, Eickholz P. Activated matrix metalloproteinase-8 in saliva as diagnostic test for periodontal disease? A case-control study. Med Microbiol Immunol 2015; 204 (06) 665-672
- 16 Johnson N, Ebersole JL, Kryscio RJ. et al. Rapid assessment of salivary MMP-8 and periodontal disease using lateral flow immunoassay. Oral Dis 2016; 22 (07) 681-687
- 17 Taylor JJ, Jaedicke KM, van de Merwe RC. et al. A prototype antibody-based biosensor for measurement of salivary MMP-8 in periodontitis using surface acoustic wave technology. Sci Rep 2019; 9 (01) 11034
- 18 Tran TB, Nguyen PD, Baek C, Min J. Electrical dual-sensing method for real-time quantitative monitoring of cell-secreted MMP-9 and cellular morphology during migration process. Biosens Bioelectron 2016; 77: 631-637
- 19 Guida L, Bencivenga D, Annunziata M. et al. An optical fiber-based point-of-care test for periodontal MMP-8 detection: a proof of concept. J Dent 2023; 134: 104553
- 20 Tortolini C, Gigli V, Angeloni A, Tasca F, Thanh NTK, Antiochia R. A disposable immunosensor for the detection of salivary MMP-8 as biomarker of periodontitis. Bioelectrochemistry 2024; 156: 108590
- 21 Sinkevicius V. Commission Recommendation 2022/C 229/01 of 10 June 2022 on the definition of nanomaterial. Official Journal of the European Union 2022
- 22 Farka Z, Juřík T, Kovář D, Trnková L, Skládal P. Nanoparticle-based immunochemical biosensors and assays: recent advances and challenges. Chem Rev 2017; 117 (15) 9973-10042
- 23 Khan I, Saeed K, Khan I. Nanoparticles: properties, applications and toxicities. Arab J Chem 2019; 12 (07) 908-931
- 24 Janmanee R, Baba A, Phanichphant S. et al. Detection of human IgG on poly(pyrrole-3-carboxylic acid) thin film by electrochemical-surface plasmon resonance spectroscopy. Jpn J Appl Phys 2011; 50 (1S2): 01BK02
- 25 Thiha A, Ibrahim F. A colorimetric enzyme-linked immunosorbent assay (ELISA) detection platform for a point-of-care dengue detection system on a lab-on-compact-disc. Sensors (Basel) 2015; 15 (05) 11431-11441
- 26 Dewan M, Shrivastava D, Goyal L. et al. Recent advancements and applications of nanosensors in oral health: revolutionizing diagnosis and treatment. Eur J Dent 2025; 19 (02) 286-297
- 27 Hou F, Sun S, Abdullah SW, Tang Y, Li X, Guo H. The application of nanoparticles in point-of-care testing (POCT) immunoassays. Anal Methods 2023; 15 (18) 2154-2180
- 28 Maduraiveeran G, Sasidharan M, Ganesan V. Electrochemical sensor and biosensor platforms based on advanced nanomaterials for biological and biomedical applications. Biosens Bioelectron 2018; 103: 113-129
- 29 Kannan A, Radhakrishnan S. Fabrication of an electrochemical sensor based on gold nanoparticles functionalized polypyrrole nanotubes for the highly sensitive detection of l-dopa. Mater Today Commun 2020; 25: 101330
- 30 Bae G, Kim M, Lee A. et al. Nanometric lamination of zinc oxide nanofilms with gold nanoparticles for self-perceived periodontal disease sensors. Compos B Eng 2022; 230: 109490
- 31 Wu Z, Wang Y, Zhang Y. et al. Ultrasensitive detection of MMP-8 in saliva for monitoring periodontitis using an Immuno-CRISPR/Cas12a assay. Sens Actuators B Chem 2024; 417: 136156
- 32 Boonprasert K, Tharavanij T, Pechyen C. et al. Validation of an electrochemical sensor based on gold nanoparticles as a point-of-care test for quantitative determination of glycated hemoglobin. PLoS One 2023; 18 (06) e0276949
- 33 Zhang L, Li X, Yan H, Huang L. Salivary matrix metalloproteinase (MMP)-8 as a biomarker for periodontitis: A PRISMA-compliant systematic review and meta-analysis. Medicine (Baltimore) 2018; 97 (03) e9642
- 34 Nędzi-Góra M, Górska R, Górski B. The utility of gingival crevicular fluid matrix metalloproteinase-8 provides site-specific diagnostic value for periodontal grading. Cent Eur J Immunol 2021; 46 (02) 236-243
- 35 Heikkinen AM, Nwhator SO, Rathnayake N, Mäntylä P, Vatanen P, Sorsa T. Pilot study on oral health status as assessed by an active matrix metalloproteinase-8 chairside mouthrinse test in adolescents. J Periodontol 2016; 87 (01) 36-40
- 36 He W, You M, Li Z. et al. Upconversion nanoparticles-based lateral flow immunoassay for point-of-care diagnosis of periodontitis. Sens Actuators B Chem 2021; 334 (01) 129673
- 37 Baidya SK, Banerjee S, Guti S, Jha T, Adhikari N. Matrix metalloproteinase-8 (MMP-8) and its inhibitors: a minireview. Eur J Med Chem Rep 2024; 10: 100130
- 38 Zhang Q, Wang Z, Shen S. et al. Integrating enzyme-nanoparticles bring new prospects for the diagnosis and treatment of immune dysregulation in periodontitis. Front Cell Infect Microbiol 2024; 14: 1494651
- 39 Imamura K, Takayama S, Saito A. et al. Evaluation of a novel immunochromatographic device for rapid and accurate clinical detection of Porphyromonas gingivalis in subgingival plaque. J Microbiol Methods 2015; 117: 4-10
- 40 Ge D, Wang F, Hu Y, Wang B, Gao X, Chen Z. Fast, simple, and highly specific molecular detection of Porphyromonas gingivalis using isothermal amplification and lateral flow strip methods. Front Cell Infect Microbiol 2022; 12: 895261