Open Access
CC BY-NC-ND 4.0 · Asian J Neurosurg 2025; 20(03): 491-497
DOI: 10.1055/s-0045-1806866
Original Article

Microscopic Minimal Invasive Resection of Spinal Tumor with Tubular Retractor System: Case Studies of 70 Patients with Literature Review

Mohan Karki
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
,
Rakesh Pandey
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
,
Manish Vaish
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
,
Girish Rajpal
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
,
Yaspal Singh Bundela
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
,
Hrishikesh Chakrabartty
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
,
Dipanshu Narula
1   Department of Neurosurgery, Max Super Speciality Hospital, Vaishali, Uttar Pradesh, India
› Institutsangaben

Funding None.
Preview

Abstract

Objective

Minimal invasive spine surgery with tubular retractor system avoids contralateral laminectomy, minimizes manipulation of midline supportive structures, and reduces surgical morbidity. The objective of this study was to evaluate the safety and efficacy of microscopic minimal invasive tubular retractor system for intradural spinal tumor resection.

Materials and Methods

A retrospective study was performed in 70 patients who were admitted between January 2017 and January 2024 with intradural spinal tumors and underwent excision with microscopic minimal invasive tubular retractor system. Patient's data including age, sex, clinical symptoms, and magnetic resonance imaging were collected. The extent of resection, surgical complications, estimated blood loss, estimated surgical time, and neurological outcomes were recorded. The neurological assessment was done by the modified McCormick grading scale pre- and postoperatively.

Results

Out of 70 patients, there were 38 (54.28%) males and 32 (45.71%) females, with a mean age of 45.16 (range: 8–79) years. The histology of these cases was meningioma (34.28%), schwannoma (51.42%), astrocytoma (2.85%), ependymoma (2.85%), and neurofibroma (8.57%). The average volume of tumors was 1.98 cm3, and gross total resection was achieved in 64 (91.53%) cases and subtotal resection was achieved in 6 (8.57%) cases. One patient had neurological deterioration, which was improved on follow-up after 6 months, and cerebrospinal fluid (CSF) leakage was noted in one case, which recovered after keeping lumbar drain for 5 days. No permanent neurological deficits were observed compared with their preoperative status, with improvement noted in visual analog scale and modified McCormick grade in all cases in the long-term follow-up evaluation (6–24 months).

Conclusion

Microscopic minimal invasive resection of intradural spinal tumor by the tubular retractor system is safe and effective with excellent neurological improvement as well as better resection rate, short hospital stay, and less surgical complication.

Authors' Contributions

M.K. conceived and designed the study, and contributed to data collection and manuscript writing and drafting of the manuscript. R.P., M.V., G.R., Y.S.B., H.C., and D.N. were responsible for editing and providing technical feedback with design and analyses.


Ethical Approval

This is a retrospective study, so informed consent was taken from the involved participants in this study. This study was approved by the Local Ethics Committee of the Max Super Speciality Hospital.


Patients' Consent

We declare that all patients involved in the study signed an informed consent approving that they agree to share their medical data in any research work and to be published.




Publikationsverlauf

Artikel online veröffentlicht:
03. April 2025

© 2025. Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)