RSS-Feed abonnieren

DOI: 10.1055/s-0044-1795079
Marginal Accuracy of Ceramic Veneer Alloy Related to Different Alloy Fabrication Techniques, Ceramic Veneering Methods, Stages, and Sites of Fabrication
Funding The authors would like to thank the Faculty of Dentistry, Khon Kean University, Ministry of Higher Education, Science, Research and Innovation, Royal Thai Government for the grant supporting this study. (Grant Number RTG 02052017).

Abstract
Objectives Fabrication processes affect accuracy of restoration. This study compared marginal accuracy of ceramic veneer metal upon different metal substructure fabrication techniques, ceramic veneering methods, stages, and sites of restoration.
Material and Methods A prepared premolar metal abutment was used to fabricate 96 metal substructures from 4 techniques: cast metal with traditionally impressed tooth (CmTt), cast metal with digitally milled wax (CmDw), sintered metal with digitally impressed tooth (SmDt), and sintered metal with digitally impressed stone model (SmDm). As-cast (A) substructures were degassed (D), opaqued (O), and contoured (C) with porcelain layering (Pl) or press-on (Pp) methods and glazed (G). Marginal fit was measured at A, D, O, C, and G stages, on buccal (Bu), lingual (Li), mesial (Me), and distal (Di) sites using silicone replica.
Statistical Analysis Analysis of variance and Bonferroni test were analyzed for significant differences of marginal fit upon different factors (α = 0.05).
Results Significantly different accuracy was found upon metal substructures fabrication technique, veneering methods, stages, and sites of restoration (p < 0.05). SmDt and SmDm revealed significantly better accuracy than CmTt and CmDw (p < 0.05). Pp generated significantly better accuracy than Pl (p < 0.05). Significant increasing inaccuracy was found at D stage (p < 0.05). Me and Di sites exhibited larger inaccuracy than Bu and Li sites (p < 0.05). However, marginal inaccuracy for all groups was under clinically acceptable marginal fit.
Conclusions Increasing marginal inaccuracies upon stages of fabrication were noticed, with highly observed at the proximal site. Sintered metal provided better accuracy than cast metal, while press-on veneering generated better accuracy than the layering method. Porcelain press-on sintered metal was suggested for fabrication restoration.
Publikationsverlauf
Artikel online veröffentlicht:
21. November 2024
© 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Kocaağaoğlu H, Kılınç Hİ, Albayrak H, Kara M. In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies. J Prosthet Dent 2016; 116 (03) 368-374
- 2 Kim EH, Lee DH, Kwon SM, Kwon TY. A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems. J Prosthet Dent 2017; 117 (03) 393-399
- 3 Önöral Ö, Ulusoy M, Seker E, Etikan İ. Influence of repeated firings on marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations fabricated with different techniques. J Prosthet Dent 2018; 120 (03) 415-420
- 4 Örtorp A, Jönsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dent Mater 2011; 27 (04) 356-363
- 5 Kim KB, Kim JH, Kim WC, Kim JH. Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies. J Prosthet Dent 2014; 112 (06) 1432-1436
- 6 Vojdani M, Torabi K, Farjood E, Khaledi A. Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by cad/cam and conventional wax up techniques. J Dent (Shiraz) 2013; 14 (03) 118-129
- 7 Tinschert J, Natt G, Hassenpflug S, Spiekermann H. Status of current CAD/CAM technology in dental medicine. Int J Comput Dent 2004; 7 (01) 25-45
- 8 Park JK, Kim HY, Kim WC, Kim JH. Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy. J Prosthet Dent 2016; 116 (06) 909-915
- 9 Farjood E, Vojdani M, Torabi K, Khaledi AA. Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing. J Prosthet Dent 2017; 117 (01) 164-170
- 10 Nesse H, Ulstein DM, Vaage MM, Øilo M. Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques. J Prosthet Dent 2015; 114 (05) 686-692
- 11 Jang Y, Sim JY, Park JK, Kim WC, Kim HY, Kim JH. Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model. J Adv Prosthodont 2018; 10 (05) 367-373
- 12 Mansour FK, Ibrahim RM, Mansour H, Hamdy AM. Assessment of internal fit and micro leakage of conventionally fabricated ceramometallic restoration versus CAD wax and press veneering (in-vitro study). BDJ Open 2021; 7 (01) 17
- 13 Fahmy NZ, Salah E. An in vitro assessment of a ceramic-pressed-to-metal system as an alternative to conventional metal ceramic systems. J Prosthodont 2011; 20 (08) 621-627
- 14 Sailer I, Fehér A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CHF. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007; 20 (04) 383-388
- 15 Ogunc A, Yildirim Avcu G. Effect of repeated firings on the marginal and internal adaptation of implant-supported metal-ceramic restorations fabricated with different thicknesses and fabrication methods. J Prosthet Dent 2021; 125 (03) 504.e1-504.e6
- 16 Patil A, Singh K, Sahoo S, Suvarna S, Kumar P, Singh A. Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: an in vitro study. Eur J Dent 2013; 7 (03) 272-277
- 17 Kunii J, Hotta Y, Tamaki Y. et al. Effect of sintering on the marginal and internal fit of CAD/CAM-fabricated zirconia frameworks. Dent Mater J 2007; 26 (06) 820-826
- 18 Kim DY, Kim JH, Kim HY, Kim WC. Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing. J Prosthodont Res 2018; 62 (01) 56-64
- 19 Bajaj GB. A comparative study of the effect of four consecutive firing cycles on the marginal fit of all: ceramic crown system and metal ceramic crown system. J Indian Prosthodont Soc 2013; 13 (03) 247-253
- 20 Altintas MA, Akin H. Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implant-supported fixed prosthesis. J Adv Prosthodont 2020; 12 (03) 167-172
- 21 Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns–validation of the silicone replica method. J Oral Rehabil 2008; 35 (02) 116-122
- 22 Boitelle P, Mawussi B, Tapie L, Fromentin O. A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 2014; 41 (11) 853-874
- 23 Gonzalo E, Suárez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 2009; 102 (06) 378-384
- 24 Ural C, Burgaz Y, Saraç D. In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques. Quintessence Int 2010; 41 (07) 585-590
- 25 Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult von Steyern P, Fukushima S. Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil 2005; 32 (07) 526-530
- 26 Pettenò D, Schierano G, Bassi F, Bresciano ME, Carossa S. Comparison of marginal fit of 3 different metal-ceramic systems: an in vitro study. Int J Prosthodont 2000; 13 (05) 405-408
- 27 Son K, Lee S, Kang SH. et al. A comparison study of marginal and internal fit assessment methods for fixed dental prostheses. J Clin Med 2019; 8 (06) 785
- 28 Proussaefs P. Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement. J Prosthodont 2004; 13 (01) 36-41
- 29 Persson AS, Odén A, Andersson M, Sandborgh-Englund G. Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness. Dent Mater 2009; 25 (07) 929-936
- 30 Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the “replica technique” in the measurement of the fit of Procera crowns. J Contemp Dent Pract 2008; 9 (02) 25-32