RSS-Feed abonnieren
DOI: 10.1055/s-0044-1789574
Optimizing Decision Support Alerts to Reduce Telemetry Duration: A Multicenter Evaluation
Funding Funding for this study was obtained from the Division of Hospital Medicine “Hospitalists Scholars Fund,” Johns Hopkins Hospital. The funding agency did not have input on the design or analysis of this study.Abstract
Background Telemetry monitoring is crucial for high-risk patients but excessive use beyond practice standards increases costs. Prior studies have shown that electronic health record (EHR) alerts reduce low-value telemetry monitoring. However, specific components of these alerts that contribute to effectiveness are unknown.
Objectives We aimed to revise previously implemented EHR Best Practice Advisories (BPAs) to optimize their effectiveness in reducing telemetry duration. The secondary objective was to assess the impact on clinicians' alert burden.
Methods A multicenter retrospective study was conducted at Johns Hopkins Hospital (JHH), Johns Hopkins Bayview Medical Center (JHBMC), and Howard County General Hospital (HCGH). An EHR alert in the form of a BPA was previously implemented at JHH/JHBMC, firing at 24, 48, or 72 hours based on order indication. HCGH used an alert firing every 24 hours. A revised BPA was implemented at all hospitals optimizing the prior JHH/JHBMC alert by including patient-specific telemetry indications, restricting alerts to daytime hours (8:00 a.m.–6:00 p.m.), and embedding the discontinuation order within the BPA alert. A retrospective analysis from October 2018 to December 2021 was performed. The primary outcome was telemetry duration. The secondary outcome was the mean monthly BPA alerts per patient-day.
Results Compared with the original BPA, the revised BPA reduced telemetry duration by a mean of 6.7 hours (95% CI: 5.2–9.1 hours, p < 0.001) at JHH/JHBMC, with a minimal increase of 0.06 mean monthly BPA alerts per patient-day (p < 0.001). The BPA acceptance rate increased from 7.8 to 31.3% postintervention at JHH/JHBMC (p < 0.0001). At HCGH, the intervention led to a mean monthly reduction of 20.2 hours in telemetry duration per hospitalization (95% CI: 19.1–22.8 hours, p < 0.0001).
Conclusion Optimizing EHR BPAs reduces unnecessary telemetry duration without substantially increasing clinician alert burden. This study highlights the importance of tailoring EHR alerts to enhance effectiveness and promote value-based care.
Protection of Human and Animal Subjects
The study was performed in compliance with the World Medical Association Declaration of Helsinki on Ethical Principles for Medical Research Involving Human Subjects and was reviewed by the Institutional Review Boards at JHH, JHBMC, and HCGH.
Publikationsverlauf
Eingereicht: 02. April 2024
Angenommen: 27. Juli 2024
Artikel online veröffentlicht:
23. Oktober 2024
© 2024. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Sandau KE, Funk M, Auerbach A. et al; American Heart Association Council on Cardiovascular and Stroke Nursing; Council on Clinical Cardiology; and Council on Cardiovascular Disease in the Young. Update to practice standards for electrocardiographic monitoring in hospital settings: a scientific statement from the American Heart Association. Circulation 2017; 136 (19) e273-e344
- 2 Cantillon DJ, Burkle A, Kirkwood D. et al. Indication-specific event rates among hospitalized patients undergoing continuous cardiac monitoring. Clin Cardiol 2019; 42 (10) 952-957
- 3 Benjamin EM, Klugman RA, Luckmann R, Fairchild DG, Abookire SA. Impact of cardiac telemetry on patient safety and cost. Am J Manag Care 2013; 19 (06) e225-e232
- 4 Kansara P, Jackson K, Dressler R. et al. Potential of missing life-threatening arrhythmias after limiting the use of cardiac telemetry. JAMA Intern Med 2015; 175 (08) 1416-1418
- 5 Knees M, Mastalerz K, Simonetti J, Berry A. Decreasing inappropriate telemetry use via nursing-driven checklist and electronic health record order set. Cureus 2022; 14 (09) e28999
- 6 Chong-Yik R, Bennett AL, Milani RV, Morin DP. Cost-saving opportunities with appropriate utilization of cardiac telemetry. Am J Cardiol 2018; 122 (09) 1570-1573
- 7 Dressler R, Dryer MM, Coletti C, Mahoney D, Doorey AJ. Altering overuse of cardiac telemetry in non-intensive care unit settings by hardwiring the use of American Heart Association guidelines. JAMA Intern Med 2014; 174 (11) 1852-1854
- 8 Xie L, Garg T, Svec D. et al. Reducing telemetry use is safe: a retrospective analysis of rapid response team and code events after a successful intervention to reduce telemetry use. Am J Med Qual 2019; 34 (04) 398-401
- 9 Najafi N, Cucina R, Pierre B, Khanna R. Assessment of a targeted electronic health record intervention to reduce telemetry duration: a cluster-randomized clinical trial. JAMA Intern Med 2019; 179 (01) 11-15
- 10 Bulger J, Nickel W, Messler J. et al. Choosing wisely in adult hospital medicine: five opportunities for improved healthcare value. J Hosp Med 2013; 8 (09) 486-492
- 11 Yeow RY, Strohbehn GW, Kagan CM. et al. Eliminating inappropriate telemetry monitoring: an evidence-based implementation guide. JAMA Intern Med 2018; 178 (07) 971-978
- 12 Edholm K, Kukhareva P, Ciarkowski C. et al. Decrease in inpatient telemetry utilization through a system-wide electronic health record change and a multifaceted hospitalist intervention. J Hosp Med 2018; 13 (08) 531-536
- 13 Duffy E, Niessen T, Perrin K. et al. Empowering nurses and residents to improve telemetry stewardship in the academic care setting. J Eval Clin Pract 2021; 27 (05) 1154-1158
- 14 Narayanan M, Starks H, Tanenbaum E, Robinson E, Sutton PR, Schleyer AM. Harnessing the electronic health record to actively support providers with guideline-directed telemetry use. Appl Clin Inform 2021; 12 (05) 996-1001
- 15 Chin KK, Svec D, Leung B, Sharp C, Shieh L. E-HeaRT BPA: electronic health record telemetry BPA. Postgrad Med J 2020; 96 (1139) 556-559
- 16 Rizvi W, Munguti CM, Mehta J, Kallail KJ, Youngman D, Antonios S. Reducing over-utilization of cardiac telemetry with pop-ups in an electronic medical record system. Cureus 2017; 9 (05) e1282
- 17 Krouss M, Israilov S, Alaiev D. et al. Tell-a provider about tele: Reducing overuse of telemetry across 10 hospitals in a safety net system. J Hosp Med 2023; 18 (02) 147-153
- 18 Bergstedt A, Hilliard B, Alabsi S. et al. Evaluation of a clinical decision support tool to guide adoption of the American Heart Association Telemetry Monitoring Practice Standards. J Am Heart Assoc 2024; 13 (09) e031523
- 19 Jankovic I, Chen JH. Clinical decision support and implications for the clinician burnout crisis. Yearb Med Inform 2020; 29 (01) 145-154
- 20 Arts DL, Medlock SK, van Weert HCPM, Wyatt JC, Abu-Hanna A. Acceptance and barriers pertaining to a general practice decision support system for multiple clinical conditions: a mixed methods evaluation. PLoS ONE 2018; 13 (04) e0193187
- 21 Tolley CL, Slight SP, Husband AK, Watson N, Bates DW. Improving medication-related clinical decision support. Am J Health Syst Pharm 2018; 75 (04) 239-246
- 22 Khan S, Richardson S, Liu A. et al. Improving provider adoption with adaptive clinical decision support surveillance: an observational study. JMIR Hum Factors 2019; 6 (01) e10245
- 23 Palchaudhuri S, Chen S, Clayton E, Accurso A, Zakaria S. Telemetry monitor watchers reduce bedside nurses' exposure to alarms by intercepting a high number of nonactionable alarms. J Hosp Med 2017; 12 (06) 447-449
- 24 Kim J, Miyazaki K, Nishimura Y, Honda R. Inappropriate telemetry use is increased during the COVID-19 era. Healthcare (Basel) 2021; 9 (12) 1610