Vet Comp Orthop Traumatol 2023; 36(05): 250-256
DOI: 10.1055/s-0043-57221
Original Research

Biomechanical Comparison of Cortical Lag Screws and Cortical Position Screws for Their Generation of Interfragmentary Compression and Area of Compression in Simulated Lateral Humeral Condylar Fractures

Lucy M. Fuchter
1   Small Animal Specialist Hospital (SASH), Sydney, Australia
,
2   Surgical and Orthopaedic Research Laboratories (SORL), UNSW Sydney, Price of Wales Clinical School, Prince of Wales Hospital, Sydney, Australia
,
2   Surgical and Orthopaedic Research Laboratories (SORL), UNSW Sydney, Price of Wales Clinical School, Prince of Wales Hospital, Sydney, Australia
,
Mark Newman
3   Western Australia Veterinary Emergency and Speciality (WAVES), Perth, Australia
,
Chris Tan
2   Surgical and Orthopaedic Research Laboratories (SORL), UNSW Sydney, Price of Wales Clinical School, Prince of Wales Hospital, Sydney, Australia
› Author Affiliations

Funding None.
Preview

Abstract

Objective The aim of this study was to compare the interfragmentary compressive force and area of compression generated by cortical screws inserted as either a lag screw or position screw in simulated lateral humeral condylar fractures.

Study DesignEx vivo biomechanical study.

Materials and Methods Thirteen pairs of cadaveric humeri from skeletally mature Merinos with simulated lateral humeral condylar fractures were used. Pressure sensitive film was inserted into the interfragmentary interface prior to fracture reduction with fragment forceps. A cortical screw was inserted as a lag screw or a position screw and tightened to 1.8Nm. Interfragmentary compression and area of compression were quantified and compared between the two treatments groups at three time points.

Results After fracture reduction using fragment forceps (Time point 1: T1), there was no significant difference in interfragmentary compression and area of compression between the two treatments. A combination of fragment forceps and a cortical screw inserted as a lag screw (Time point 2: T2) produced significantly greater interfragmentary compression and area of compression compared with the same screw inserted as a positional screw. After removal of the fragment forceps, leaving only the cortical screw (Time point 3: T3), both the interfragmentary compression and area of compression remain significantly greater in the lag screw group.

Conclusion Lag screws generate a greater force of compression and area of compression compared with position screws in this mature ovine humeral condylar fracture model.

Authors' Contributions

C.T. conceptualized the study. C.T., M.N. and L.F. were involved in study design. L.F. was responsible for the acquisition of data, and DW for data analysis. L.F. drafted the manuscript, and all authors were involved in its revision.




Publication History

Received: 02 December 2022

Accepted: 24 March 2023

Article published online: