Open Access
CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2023; 58(05): e719-e726
DOI: 10.1055/s-0043-1776136
Artigo Original
Ombro e Cotovelo

MRI is a Reliable Method for Measurement of Critical Shoulder Angle and Acromial Index

Artikel in mehreren Sprachen: português | English
1   Professor adjunto, Departamento de Ortopedia, Faculdade de Medicina, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brasil
2   Cirurgião ortopédico, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
,
Erika Naliato
1   Professor adjunto, Departamento de Ortopedia, Faculdade de Medicina, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brasil
,
Roberto Oliveira
3   Cirurgião ortopédico, ex-membro do Grupo de Ombro e Cotovelo do Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
,
Leonardo Tadeu do Carmo
3   Cirurgião ortopédico, ex-membro do Grupo de Ombro e Cotovelo do Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
,
César Rubens da Costa Fontenelle
1   Professor adjunto, Departamento de Ortopedia, Faculdade de Medicina, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brasil
,
Geraldo da Rocha Motta Filho
2   Cirurgião ortopédico, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
› Institutsangaben


Financial Support The present survey has not received any specific funding from public, commercial, or not-for-profit funding agencies.
Preview

Abstract

Objective The objectives of this study are to compare absolute values of acromial index (AI) and critical shoulder angle (CSA) obtained in both radiographs and magnetic resonance image (MRI) of the shoulder; and to compare the interobserver and intra-observer agreement for AI and CSA values measured in these image modalities.

Methods Patients who had medical indication of investigating shoulders conditions through radiographs and MRI were included. Images were taken to two fellowship-trained shoulder surgeons, which conducted measurements of AI and CSA in radiographs and in MRI. Twelve weeks after the first evaluation, a second evaluation was conducted. Inter- and intra-observer reliability was presented as an Intraclass Correlation Coefficient (ICC) and agreement was classified according to Landis & Koch criteria. The differences between two measurements were evaluated using Bland-Altman plots.

Results 134 shoulders in 124 subjects were included. Mean intra-observer ICC for CSA in X-rays and in MRI were 0.936 and 0.940, respectively; for AI, 0.908 and 0.022. Mean inter-observer ICC for CSA were 0.892 and 0.752 in X-rays and MRI respectively; for AI, ICC values were 0.849 and 0.685. All individual analysis reached statistical power (p < 0.001). Mean difference for AI values measured in X-rays and in MRI was 0.01 and 0.03 for observers 1 and 2, respectively. Mean difference for CSA values obtained in X-rays and MRI was 0.16 and 0.58 for observers 1 and 2, respectively.

Conclusion Both MRI and X-rays provided high intra- and interobserver agreement for measurement of AI and CSA. Absolute values found for AI and CSA were highly correlated in both image modalities. These findings suggest that MRI is a suitable method to measure AI and CSA.

Level of Evidence II, Diagnostic Study.

Work developed in the National Institute of Trauma and Orthopedics Rio de Janeiro, RJ, Brazil.




Publikationsverlauf

Eingereicht: 19. März 2023

Angenommen: 05. Mai 2023

Artikel online veröffentlicht:
30. Oktober 2023

© 2023. Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Revinter Publicações Ltda.
Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, Brazil