Open Access
CC BY 4.0 · Eur J Dent 2024; 18(01): 065-072
DOI: 10.1055/s-0043-1768472
Review Article

The Effect of Dental Implant Drills Materials on Heat Generation in Osteotomy Sites: A Systematic Review

Shreyasi Chakraborty
1   Department of Implant Dentistry, BPP University, Birmingham, United Kingdom
,
2   Department of Preventive and Restorative Dentistry, College of Dental Medicine University of Sharjah, Sharjah, United Arab Emirates
3   Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
,
Waad Kheder
2   Department of Preventive and Restorative Dentistry, College of Dental Medicine University of Sharjah, Sharjah, United Arab Emirates
3   Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
› Institutsangaben
Preview

Abstract

The aim of this review was to examine the impact of dental implant drill materials and wear profiles on heat generation in the osteotomy sites as reported in experimental studies and to critically appraise these studies. The research question was formulated based on predefined patient, intervention, comparison, and outcome (PICO) elements. A comprehensive electronic search was undertaken in Medline/PubMed Central, Science Direct, and Google Scholar, using predetermined keywords, followed by a manual search of the bibliography of the selected articles. The selection of the studies for the critical appraisal part of our study was based on the criteria used to assess the study designs such as study aims, outcome measure, clarity of method, sample selection, randomization, allocation concealment, sample attrition, bias, method of data analysis, and external validity. Increased heat generation was observed with both ceramic and metal drills; the heat generation was proportional to drills' wear. The literature was inconclusive regarding the association between drill material and heat generation. However, drill materials had a significant influence on the overall temperature increase during osteotomy. The noncoated drills showed a higher wear resistance, and it has been observed that using worn drills leads to more friction contact, reduced drill cutting efficiency, and increased heat generation. Eleven in vitro studies met the inclusion criteria, and showed a considerable methodological heterogeneity and confounding factors, including drill geometry, speed and load, depth and diameter, number of uses, irrigation protocol, study specimens, and the heat measuring device. Besides, most of the studies have a potential operator and assessor bias, and some have sponsorship bias. It is possible to conclude that the literature is not conclusive on the effect of drill materials on heat generation during osteotomy. Lack of standardization and uniformity in the study design, along with potential bias in the study methodology can be the reason for the heterogeneity of the results.



Publikationsverlauf

Artikel online veröffentlicht:
19. Juni 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India