CC BY-NC-ND 4.0 · Endosc Int Open 2017; 05(08): E784-E791
DOI: 10.1055/s-0043-112494
Original article
Eigentümer und Copyright ©Georg Thieme Verlag KG 2017

Clinical impact of EUS treatment of walled-off pancreatic necrosis with dedicated devices

Ilaria Tarantino
1   Endoscopy Service, Department of Diagnostic and Therapeutic Services, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy
,
Dario Ligresti
1   Endoscopy Service, Department of Diagnostic and Therapeutic Services, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy
,
Fabio Tuzzolino
2   Research Office, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione)
,
Luca Barresi
1   Endoscopy Service, Department of Diagnostic and Therapeutic Services, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy
,
Gabriele Curcio
1   Endoscopy Service, Department of Diagnostic and Therapeutic Services, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy
,
Antonino Granata
1   Endoscopy Service, Department of Diagnostic and Therapeutic Services, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy
,
Mario Traina
1   Endoscopy Service, Department of Diagnostic and Therapeutic Services, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy
› Author Affiliations
Further Information

Publication History

submitted 15 December 2016

accepted after revision 29 March 2017

Publication Date:
07 August 2017 (online)

Abstract

Background and study aims Walled-off pancreatic necrosis (WOPN) represents the major risk factor for sepsis-related multiple organ failure. Surgical debridement is an invasive approach associated with high rates of adverse events (AEs) and death. As an alternative, endoscopic ultrasound-guided cysto-gastro-anastomosis has emerged as an effective treatment for WOPNs. Recently a new dedicated-lumen apposing metal stent (LAMS) has been used with satisfactory results in treating peri-pancreatic fluid collections, including WOPNs. The primary outcomes of this study were to evaluate survival and clinical success. Secondary outcomes included: technical success, adverse events and recurrence rate.

Patients and methods All consecutive patients with infected WOPN between February 2014 and June 2016 were retrospectively reviewed. Patients underwent placement of a new LAMS incorporated in an electrocautery-enhanced delivery system and direct endoscopic necrosectomy (DEN). DEN was performed immediately after stent deployment and repeated every 3 to 7 days until complete resolution.

Results In the study period we treated 20 consecutive patients with infected WOPN using the new LAMS. Technical success was achieved in 95 % of patients. Clinical success was achieved in 73 % and 84.2 % of patients at 1 and 3 months, respectively. Survival rate was 84.2 % and 79 %. Mean length of hospital stay was 19 days (range 3 – 43). No AEs occurred. Patients were followed up after stent retrieval for a mean time of 554,7 days (range 70 – 986) and no recurrence was observed.

Conclusions DEN following “1-step, exchange-free” LAMS positioning recorded excellent results. We believe that simplicity of procedure plays a key role in terms of safety.

 
  • References

  • 1 Dellinger EP, Forsmark CE, Layer P. et al. Determinant-based classification of acute pancreatitis severity: an international multidisciplinary consultation. Ann Surg 2012; 256: 875-880
  • 2 Rau B, Bothe A, Beger HG. Surgical treatment of necrotizing pancreatitis by necrosectomy and closed lavage: changing patient characteristics and outcome in a 19-year, single-center series. Surgery 2005; 138: 28-39
  • 3 Büchler MW, Gloor B, Müller CA. et al. Acute necrotizing pancreatitis: treatment strategy according to the status of infection. Ann Surg 2000; 232: 619-626
  • 4 Rodriguez JR, Razo AO, Targarona J. et al. Debridement and closed packing for sterile or infected necrotizing pancreatitis: insights into indications and outcomes in 167 patients. Ann Surg 2008; 247: 294-299
  • 5 Connor S, Alexakis N, Raraty MG. et al. Early and late complications after pancreatic necrosectomy. Surgery 2005; 137: 499-505
  • 6 Tsiotos GG, Luque-de León E, Sarr MG. Long-term outcome of necrotizing pancreatitis treated by necrosectomy. Br J Surg 1998; 85: 1650-1653
  • 7 Howard TJ, Patel JB, Zyromski N. et al. Declining morbidity and mortality rates in the surgical management of pancreatic necrosis. J Gastrointest Surg 2007; 11: 43-49
  • 8 Baril NB, Ralls PW, Wren SM. et al. Does an infected peripancreatic fluid collection or abscess mandate operation?. Ann Surg 2000; 231: 361-367
  • 9 Neff R. Pancreatic pseudocysts and fluid collections: percutaneous approaches. Surg Clin North Am 2001; 81: 399-403
  • 10 Seewald S, Ang TL, Kida M. et al. EUS 2008 Working Group document: evaluation of EUS-guided drainage of pancreatic-fluid collections (with video). Gastrointest Endosc 2009; 69: S13-21
  • 11 Bakker OJ, van Santvoort HC, van Brunschot S. et al. Endoscopic Transgastric vs Surgical Necrosectomy for Infected Necrotizing Pancreatitis. JAMA 2012; 307: 1053-1061
  • 12 Baron TH, Thaggard WG, Morgan DE. et al. Endoscopic therapy for organized pancreatic necrosis. Gastroenterology 1996; 111: 755-764
  • 13 Yasuda I, Nakashima M, Iwai T. et al. Japanese multicenter experienceof endoscopic necrosectomy for infected walled-off pancreatic necrosis: the JENIPaN study. Endoscopy 2013; 45: 627-634
  • 14 Gardner TB, Coelho-Prabhu N, Gordon SR. et al. Direct endoscopic necrosectomy for the treatment of walled-off pancreatic necrosis: results from a multicenter U.S. series. Gastrointest Endosc 2011; 73: 718-726
  • 15 Papachristou GI, Takahashi N, Chahal P. et al. Peroral endoscopic drainage/debridement of walled-off pancreatic necrosis. Ann Surg 2007; 245: 943-951
  • 16 Saxena P, Singh VK, Messallam A. et al. Resolution of walled-off pancreatic necrosis by EUS-guided drainage when using a fully covered through-the-scope self-expandable metal stent in a single procedure (with video). Gastrointest Endosc 2014; 80: 319-324
  • 17 Talreja JP, Shami VM, Ku J. et al. Transenteric drainage of pancreatic fluid collections with fully covered self-expanding metallic stents (with video). Gastrointest Endosc 2008; 68: 1199-1203
  • 18 Belle S, Collet P, Post S. et al. Temporary cystogastrostomy with self expanding metallic stents for pancreatic necrosis. Endoscopy 2010; 42: 493-495
  • 19 Fabbri C, Luigiano C, Cennamo V. et al. Endoscopic ultrasound-guided transmural drainage of infected pancreatic fluid collections with placement of covered self-expanding metal stents: a case series. Endoscopy 2012; 44: 429-433
  • 20 Penn DE, Draganov PV, Wagh MS. et al. Prospective evaluation of the use of fully covered self-expanding metal stents for EUS-guided transmural drainage of pancreatic pseudocysts. Gastrointest Endosc 2012; 76: 679-684
  • 21 Weilert F, Binmoeller KF, Shah JN. et al. Endoscopic ultrasound-guided drainage of pancreatic fluid collections with indeterminate adherence using temporary covered metal stents. Endoscopy 2012; 44: 780-783
  • 22 Binmoeller KF, Shah J. A novel lumen-apposing stent for transluminal drainage of nonadherent extraintestinal fluid collections. Endoscopy 2011; 43: 337-342
  • 23 Itoi T, Binmoeller KF, Shah J. et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos). Gastrointest Endosc 2012; 75: 870-876
  • 24 Shah RJ, Shah JN, Waxman I. et al. Safety and Efficacy of Endoscopic Ultrasound- Guided Drainage of Pancreatic Fluid Collections With Lumen-Apposing Covered Self-Expanding Metal Stents. Clin Gastroenterol Hepatol 2014; 13: 747-752
  • 25 Rinninella E, Kunda R, Dollhopf M. et al. EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: a large retrospective study (with video). Gastrointest Endosc 2015; 82: 1039-1046
  • 26 Banks PA, Bollen TL, Dervenis C. et al. Classification of acute pancreatitisd2012: revision of the Atlanta classification and definitions by international consensus. Gut 2013; 62: 102-111
  • 27 Gornals JB, De la Serna-Higuera C, Sánchez-Yague A. et al. Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent. Surg Endosc 2013; 27: 1428-1434
  • 28 Yamamoto N, Isayama H, Kawakami H. et al. Preliminary report on a new, fully covered, metal stent designed for the treatment of pancreatic fluid collections. Gastrointest Endosc 2013; 77: 809-814
  • 29 Chandran S, Efthymiou M, Kaffes A. et al. Management of pancreatic collections with a novel endoscopically placed fully covered self-expandable metal stent: a national experience (with videos). Gastrointest Endosc 2015; 81: 127-135
  • 30 Walter D, Will U, Sanchez-Yague A. et al. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a prospective cohort study. Endoscopy 2015; 47: 63-67
  • 31 Mukai S, Itoi T, Baron TH. et al. Endoscopic ultrasound-guided placement of plastic vs. biflanged metal stents for therapy of walled-off necrosis: a retrospective single-center series. Endoscopy 2015; 47: 47-55
  • 32 Shah J, Shah JN, Waxman I. et al. EUS-guided drainage of pancreatic pseudocysts (PP) utilizing a novel anchoring, covered self-expanding metal stent (Acsems): results from a prospective, multi-center study. Gastrointest Endosc 2013; 77: AB128
  • 33 Gruber RP, Vistnes L, Pardoe R. The effect of commonly used antiseptics on wound healing. Plast Reconstr Surg 1975; 55: 472-476
  • 34 Abdelhafez M, Elnegouly M, Hasab Allah MS. Transluminal retroperitoneal endoscopic necrosectomy with the use of hydrogen peroxide and without external irrigation: a novel approach for the treatment of walled-off pancreatic necrosis. Surg Endosc 2013; 27: 3911-3920
  • 35 Siddiqui AA, Easler J, Strongin A. et al. Hydrogen peroxide-assisted endoscopic necrosectomy for walled-off pancreatic necrosis: a dual center pilot experience. Dig Dis Sci 2014; 59: 687-690
  • 36 Bang JY, Hasan M, Navaneethan U. et al. Lumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: may not be business as usual. Gut 2016; DOI: 10.1136/gutjnl-2016-312812.
  • 37 Bang JY, Hasan MK, Navaneethan U. et al. Lumen apposing metal stents (LAMS) for drainage of pancreatic fluid collections: when and for whom?. Dig Endosc 2017; 29: 83-90