CC BY-NC-ND 4.0 · Indian J Radiol Imaging 2022; 32(03): 324-331
DOI: 10.1055/s-0042-1754317
Original Article

Stent-Graft Migration Post-Endovascular Repair of Thoracic Aorta: A Retrospective Cohort Study

1   Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
,
1   Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
,
Manish Shaw
1   Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
,
Sanjeev Kumar
1   Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
,
1   Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
,
Sanjiv Sharma
1   Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
,
Shiv Choudhary
2   Department of Cardiothoracic and Vascular Surgery, All India Institute of Medical Sciences, New Delhi, India
› Author Affiliations

Abstract

Background Migration of the stent-graft post-thoracic endovascular aortic repair (TEVAR) is not uncommon; however, it is sparsely reported. The objective of this study was to assess the incidence, risk factors, and complications of stent-graft migration post-TEVAR.

Materials and Methods Thirty-one patients who underwent TEVAR were retrospectively analyzed. The demographic, anatomical, and procedure-related factors were assessed. The measurements were done along the greater curvature of aorta around two fixed anatomic landmarks, that is, left common carotid artery or neoinnominate artery (hybrid repair) proximally and celiac artery distally. Aortic elongation and migration at proximal, distal, as well as at overlapping zone were measured. More than 10 mm of migration was considered significant.

Results Significant migration was observed in six (19%) patients. No significant migration was observed in the overlapping zone. The proximal landing zone 3 (odds ratio [OR] 12.78, p 0.01) was a significant risk factor, whereas landing zone 2 was a protective factor against the migration (OR 0.08, p 0.02). The odds for migration were more in segments I/3 and II/3 compared with I/2 and II/2, respectively, as per Modified Arch Landing Areas Nomenclature. A single complication was seen in the migration group which was treated by an overlapping stent graft.

Conclusion The stent-graft migration after TEVAR is not uncommon. Type 3 proximal landing zone was a significant risk factor for migration with an increased risk toward I/3 and II/3. Proximal landing zone 2 as well as adequate overlapping distance in multiple stent grafts can prevent migration.

Ethical Approval No IECPG-227/24.06.2020

Meeting Presentation

None.


Ethical Approval

Institute of Ethics Committee for Post Graduate Research, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110029, India (Ref No. IECPG-227/24.06.2020).


Financial Grant

None.




Publication History

Article published online:
31 July 2022

© 2022. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Nation DA, Wang GJ. TEVAR: endovascular repair of the thoracic aorta. Semin Intervent Radiol 2015; 32 (03) 265-271
  • 2 Daye D, Walker TG. Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. Cardiovasc Diagn Ther 2018; 8 (Suppl. 01) S138-S156
  • 3 O'Neill S, Greenberg RK, Resch T. et al. An evaluation of centerline of flow measurement techniques to assess migration after thoracic endovascular aneurysm repair. J Vasc Surg 2006; 43 (06) 1103-1110
  • 4 Piffaretti G, Negri S, Ferraro S. et al. Delayed graft dislocation after thoracic aortic endovascular repair. Kathmandu Univ Med J (KUMJ) 2014; 12 (46) 97-100 (KUMJ)
  • 5 Geisbüsch P, Skrypnik D, Ante M. et al. Endograft migration after thoracic endovascular aortic repair. J Vasc Surg 2019; 69 (05) 1387-1394
  • 6 Iwakoshi S, Ichihashi S, Inoue T. et al. Measuring the greater curvature length of virtual stent graft can provide accurate prediction of stent graft position for thoracic endovascular aortic repair. J Vasc Surg 2019; 69 (04) 1021-1027
  • 7 Demertzis S, Hurni S, Stalder M, Gahl B, Herrmann G, Van den Berg J. Aortic arch morphometry in living humans. J Anat 2010; 217 (05) 588-596
  • 8 Ishimaru S. Endografting of the aortic arch. J Endovasc Ther 2004; 11 (Suppl. 02) II62-II71
  • 9 Marrocco-Trischitta MM, de Beaufort HW, Secchi F. et al. A geometric reappraisal of proximal landing zones for thoracic endovascular aortic repair according to aortic arch types. J Vasc Surg 2017; 65 (06) 1584-1590
  • 10 Riambau V, Böckler D, Brunkwall J. et al; Esvs Guidelines Committee. Editor's Choice - management of descending thoracic aorta diseases: clinical practice guidelines of the European Society for Vascular Surgery (ESVS). Eur J Vasc Endovasc Surg 2017; 53 (01) 4-52
  • 11 Matsumura JS, Melissano G, Cambria RP. et al; Zenith TX2 Clinical Trial Investigators. Five-year results of thoracic endovascular aortic repair with the Zenith TX2. J Vasc Surg 2014; 60 (01) 1-10
  • 12 Morales JP, Greenberg RK, Morales CA. et al. Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: intermediate- and long-term outcomes. J Vasc Surg 2008; 48 (01) 54-63
  • 13 Hassoun HT, Mitchell RS, Makaroun MS, Whiting AJ, Cardeira KR, Matsumura JS. Aortic neck morphology after endovascular repair of descending thoracic aortic aneurysms. J Vasc Surg 2006; 43 (01) 26-31
  • 14 Makaroun MS, Dillavou ED, Wheatley GH, Cambria RP, Gore TAG. Gore TAG Investigators. Five-year results of endovascular treatment with the Gore TAG device compared with open repair of thoracic aortic aneurysms. J Vasc Surg 2008; 47 (05) 912-918
  • 15 Foley PJ, Criado FJ, Farber MA. et al; VALOR Investigators. Results with the Talent thoracic stent graft in the VALOR trial. J Vasc Surg 2012; 56 (05) 1214-21.e1
  • 16 Nasr B, Savean J, Albert B. et al. Thoracic stent-graft migration: the role of the geometric modifications of the stent-graft at 3 years. Ann Vasc Surg 2019; 58: 16-23
  • 17 Altnji HE, Bou-Saïd B, Walter-Le Berre H. Morphological and stent design risk factors to prevent migration phenomena for a thoracic aneurysm: a numerical analysis. Med Eng Phys 2015; 37 (01) 23-33
  • 18 Molony DS, Kavanagh EG, Madhavan P, Walsh MT, McGloughlin TM. A computational study of the magnitude and direction of migration forces in patient-specific abdominal aortic aneurysm stent-grafts. Eur J Vasc Endovasc Surg 2010; 40 (03) 332-339
  • 19 Marrocco-Trischitta MM, van Bakel TM, Romarowski RM. et al. The Modified Arch Landing Areas Nomenclature (MALAN) improves prediction of stent graft displacement forces: proof of concept by computational fluid dynamics modelling. Eur J Vasc Endovasc Surg 2018; 55 (04) 584-592
  • 20 Asenbaum U, Schoder M, Schwartz E. et al. Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks. Eur Radiol 2019; 29 (12) 6385-6395
  • 21 Melissano G, Civilini E, Bertoglio L. et al. Results of endografting of the aortic arch in different landing zones. Eur J Vasc Endovasc Surg 2007; 33 (05) 561-566