CC BY-NC-ND 4.0 · J Reconstr Microsurg Open 2022; 07(01): e7-e12
DOI: 10.1055/s-0042-1748885
Original Article

Fibrin Sealants Do Not Reduce the Rate of Seroma Formation in Postmastectomy Breast Reconstruction: A Systematic Review and Meta-analysis

Karen E. M. Massada
1   Department of General Surgery, Mercy Catholic Medical Center, Philadelphia, Pennsylvania
,
Meagan Wu
2   Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania
,
Theresa K. Webster
3   Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania
,
Juliet Panichella
3   Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania
,
Michael C. Coronado
3   Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania
,
Lindsay Talemal
3   Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania
,
Nicholas Elmer
2   Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania
,
Sthefano Araya
4   Division of Plastic and Reconstructive Surgery, Fox Chase Cancer Center, Temple University, Philadelphia, Pennsylvania
,
Rohan Brebion
3   Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania
,
Pablo A. Baltodano
4   Division of Plastic and Reconstructive Surgery, Fox Chase Cancer Center, Temple University, Philadelphia, Pennsylvania
,
Sameer A. Patel
4   Division of Plastic and Reconstructive Surgery, Fox Chase Cancer Center, Temple University, Philadelphia, Pennsylvania
› Author Affiliations

Abstract

Background Breast reconstruction using deep inferior epigastric perforator (DIEP) and latissimus dorsi (LD) flaps following mastectomy are associated with seroma formation, most commonly at the donor site. We sought to perform an updated systematic review and meta-analysis on the effects of fibrin sealant on donor-site complications following DIEP and LD flap breast reconstruction.

Methods A comprehensive literature search was conducted (March 2021) in PubMed, OVID, and Cochrane databases. Articles analyzing the efficacy of fibrin glue in reducing donor-site morbidity in DIEP and LD breast reconstruction were included. The outcomes assessed were seroma formation and duration of drainage.

Results A total of 17,265 articles were screened, and 9 articles were selected for analysis, which comprised 632 surgical sites in 611 patients. Comparing fibrin glue and quilting to quilting alone showed no significant difference in seroma formation (pooled risk ratio [RR]: 0.51; 95% confidence interval [CI]: 0.12, 2.25). Similarly, comparing fibrin glue alone to no fibrin glue showed no significant difference in seroma formation (pooled RR: 1.03; 95% CI: 0.66, 1.61) or duration of drain (pooled RR: −0.85; 95% CI: −4.09, 2.40); there was however a difference in duration of drain in those who received fibrin glue and quilting versus quilting alone (pooled RR: −2.13; 95% CI: −3.27, −0.99).

Conclusion The existing literature supports that the use of fibrin glue is not associated with a decrease in seroma formation in DIEP and LD flaps and is weakly associated with a reduction in the drainage duration only if used in conjunction with quilting.



Publication History

Received: 29 July 2021

Accepted: 19 February 2022

Article published online:
28 June 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA