J Am Acad Audiol 1999; 10(07): 355-370
DOI: 10.1055/s-0042-1748508
Original Article

Prediction and Statistical Evaluation of Speech Recognition Test Scores

Gerald A. Studebaker
School of Audiology and Speech-Language Pathology, The University of Memphis, Memphis, Tennessee
,
Ginger A. Gray
School of Audiology and Speech-Language Pathology, The University of Memphis, Memphis, Tennessee
,
William E. Branch
School of Audiology and Speech-Language Pathology, The University of Memphis, Memphis, Tennessee
› Institutsangaben

Abstract

A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an average person with the same hearing loss. The elements needed to make such evaluations are discussed. Also, a trial of the procedure is described. The primary purpose of the trial was to obtain data that would provide a basis for statistical probability statements about individual monosyllabic word test results obtained in clinical settings. Data were collected from three audiology clinics in three different types of settings. Except for a few cases with highly asymmetric speech scores, all nonconductive hearing losses were included. Subject ages ranged from 8 to 92 years. Importance-weighted average pure-tone hearing losses ranged from 0.4 to 97.6 dB HL. Fifty-word recognition scores and audiograms for 2609 ears were included in the main analysis. Twenty-five-word recognition scores and audiograms for another 932 ears from one clinic were used in a subsidiary analysis. Results indicated that distributions of absolute speech recognition scores in hearing-impaired samples are highly skewed. However, after transformation of the scores into rationalized arcsine units (rau), the differences between individual subject scores and scores predicted from the audiogram were reasonably well described by the normal distribution. The standard deviation of this distribution of differences, for the data combined across the three audiology clinics, was approximately 13 rau.

Abbreviations: AI = articulation index, CD = compact disc, FIF = frequency importance function, HLD = hearing loss desensitization, IIF = intensity importance function, IWHL = importance-weighted hearing loss, MSHC = Memphis Speech and Hearing Center, MVAH = Memphis Veterans Administration Hospital, NU-6 = Northwestern University Auditory Test No. 6, PL = presentation level, rau = rationalized arcsine units, SII = speech intelligibility index, SL = sensation level, SLD = speech level desensitization, STEPS = Speech Test Evaluation and Presentation System, SRT = speech recognition threshold, STI = speech transmission index, TF = transfer function, UMMS = University of Maryland Medical System, WAI = weighted audibility index



Publikationsverlauf

Artikel online veröffentlicht:
02. Mai 2022

© 1999. American Academy of Audiology. This article is published by Thieme.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • REFERENCES

  • American National Standards Institute. (1969). American National Standards Methods for the Calculation of the Articulation Index. (ANSI S3.5–1969). New York: ANSI.
  • American National Standards Institute. (1997). American National Standards Methods for the Calculation of the Speech Intelligibility Index. (ANSI S3.5–1997.) New York: ANSI.
  • Bartlett MS. (1947). The use of transformations. Biometrics 3:39–52.
  • Beranek L. (1947). The design of speech communication system. Proceedings of the Institute of Radio Engineers. 35:880–890.
  • Dillon H. (1982). A quantitative examination of the sources of speech discrimination test score variability. Ear Hear 3:51–58.
  • Fletcher H, Galt RH. (1950). The perception of speech and its relation to telephony. J Acoust Soc Am 22:89–151.
  • French NR, Steinberg JC. (1947). Factors governing the intelligibility of speech sounds. J Acoust Soc Am 19:90–119.
  • Halpin C, Thornton A, Hasso M. (1994). Low-frequency sensorineural loss: clinical evaluation and implications for hearing aid fitting. Ear Hear 15:71–81.
  • Halpin C, Thornton A, Hou Ζ. (1996) The articulation index in clinical diagnosis and hearing aid fitting. Curr Opin Otolaryngol Head Neck Surg 4:325–334.
  • Harris JD. (1965). Speech audiometry. In: Glorig A, ed. Audiometry Principles and Practice. Baltimore: Williams and Wilkins: 151–169.
  • Hirsh IJ, Davis H, Silverman SR, Reynolds E, Eldert E, Benson RW. (1952). Development of materials for speech audiometry. J Speech Hear Disord 17:321–337.
  • Hou Ζ, Thornton AR. (1994). A model to evaluate and maximize hearing aid performance by integrating the articulation index across listening conditions. Ear Hear 15:105–112.
  • Jandel Scientific. (1994). TableCurve 2D Windows V2.0. San Rafael, CA: Jandel Scientific.
  • Jerger J. (1998). Audiometric practices [editorial]. J Am Acad Audiol 9:85–86.
  • Kryter KD. (1962). Methods for the calculation and use of the articulation index. J Acoust Soc Am 34:1689–1697.
  • Lotus Development Corporation. (1994). Lotus-123 Release 5. Cambridge, MA: Lotus Development Corp.
  • Martin FN, Champlin CA, Chambers JA. (1998). Seventh Survey of Audiometric Practices in the United States. J Am Acad Audiol 9:95–104.
  • Newby HA. (1958). Audiology, Principles and Practice. New York: Appleton-Century-Crofts.
  • Pavlovic CV. (1994). Band importance functions for audi-ological applications. Ear Hear 15:100–104.
  • Pavlovic CV, Studebaker GA, Sherbecoe RL. (1986). An articulation index based procedure for predicting the speech recognition performance of hearing-impaired subjects. J Acoust Soc Am 80:50–57.
  • Schum DJ, Matthews LJ, Lee F. (1991). Actual and predicted word-recognition performance of elderly hearing-impaired listeners. J Speech Hear Res 34:636–642.
  • Shore I, Bilger RC, Hirsh IJ. (1960). Hearing aid evaluation: reliability of repeated measurements. J Speech Hear Disord 25:152–170.
  • Steeneken HJM, Houtgast T. (1980). A physical method for measuring speech-transmission quality. J Acoust Soc Am 67:318–326.
  • Studebaker GA. (1985). A rationalized arcsine transform. J Speech Hear Res 28:455–462.
  • Studebaker GA. (1991). Measures of intelligibility and quality. In: Studebaker GA, Bess FH, and Beck L, eds. The Vanderbiltι /Hearing-Aid-Report II. Parkton, MD: York Press: 185–199.
  • Studebaker GA. (1992, May). Steps toward a General Predictive Model of Average Speech Recognition Performance. Paper presented at the Arrowhead Conference on Issues in Advanced Hearing Aid Research II, Arrowhead, CA.
  • Studebaker GA, ed. (1995). User Instruction Manual for UMAPS. Unpublished instruction manual for the University of Memphis Audiometrie Programs. Memphis, TN: School of Audiology and Speech Language Pathology, University of Memphis.
  • Studebaker GA, McDaniel MD, Sherbecoe RL. (1995). Evaluating relative speech recognition performance using the proficiency factor and rationalized arcsine differences. J Am Acad Audiol 6:173–182.
  • Studebaker GA, Sherbecoe RL. (1991). Frequency-importance and transfer functions for recorded CID W-22 word lists. J Speech Hear Res 34:427–438.
  • Studebaker GA, Sherbecoe RL. (1992). A Model for the Prediction of Average Speech Recognition Performance of Normal-hearing and Hearing-impaired Persons. Unpublished laboratory report 92–03. Memphis, TN: Hearing Science Laboratory, University of Memphis.
  • Studebaker GA, Sherbecoe RL. (1993). Frequency-importance functions for speech recognition. In: Studebaker GA, Hochberg I, eds. Acoustical Factors Affecting Hearing Aid Performance. (2nd ed.) Needham Heights, MA: Allyn and Bacon, 185–204.
  • Studebaker GA, Sherbecoe RL. (1994, May-June). Evaluating the Speech Recognition Performance of Hearing-impaired Listeners. Paper presented at the Lake Arrowhead Conference on Issues in Advanced Hearing Aid Research, Lake Arrowhead, CA.
  • Studebaker GA, Sherbecoe RL, Gilmore C. (1991, November). Model Predicting Average Speech Recognition Performance under Circumscribed Conditions. Poster paper presented at the annual meeting of the American Speech Language Hearing Association, Atlanta, GA.
  • Studebaker GA, Sherbecoe RL, Gilmore C. (1993). Frequency-importance and transfer functions for the Auditec of St. Louis recordings of the NU-6 word test. J Speech Hear Res 36:799–807.
  • Studebaker GA, Sherbecoe RL, McDaniel DM, Gray GA. (1997). Age-related changes in monosyllabic word recognition performance when audibility is held constant. J Am Acad Audiol 8:150–162.
  • Studebaker GA, Sherbecoe RL, McDaniel DM, Gwaltney CA. (1999). Monosyllabic word recognition at higher than normal speech and noise levels. J Acoust Soc Am 105:2431–2444.
  • Thornton AR, Raffin MJ. (1978). Speech discrimination scores modeled as a binomial variable. J Speech Hear Res 21:507–518.
  • Tillman TW, Carhart R. (1966). An Expanded Test for Speech Discrimination Utilizing CNC Monosyllabic Words. (Northwestern University Auditory Test No. 6). Technical report SAM-TR66–55. Brooks Air Force Base, TX: USAF School of Aerospace Medicine, Aerospace Medical Division.