Int J Angiol 2023; 32(04): 308-311
DOI: 10.1055/s-0042-1747672
Case Report

Bail-Out TEVAR through a Branch of Four-Arm Dacron Graft for Misdeployment of a Frozen Elephant Trunk Prosthesis

Yuta Kikuchi
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
,
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
,
Ryohei Ushioda
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
,
Tomonori Shirasaka
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
,
Hiroyuki Kamiya
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
› Author Affiliations
Funding None.

Abstract

The frozen elephant trunk (FET) is an effective method for making the distal anastomosis more proximal and facilitating aortic remodeling in acute aortic dissection. However, misdeployment of FET to the false lumen has been reported in several cases. Such cases are usually treated with bail-out thoracic endovascular aortic repair (TEVAR) through the femoral artery or additional FET under direct vision to redirect the blood flow to the true lumen. We encountered a case of misdeployment of FET into the false lumen during open aortic surgery for the treatment of Stanford type A acute aortic dissection. After reconstruction of the aorta and all arch vessels, we performed antegrade bail-out TEVAR through a side branch of the four-arm Dacron graft as main access using a pull-through technique through the right femoral artery, which was perfused from the true lumen. This technique, which uses a Dacron graft branch for stent graft access, enabled us to confirm the true lumen because the distal anastomotic site was definitely the true lumen, and we were also able to avoid access difficulties at the iliac artery.



Publication History

Article published online:
29 May 2022

© 2022. International College of Angiology. This article is published by Thieme.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Leone A, Di Marco L, Coppola G. et al. Open distal anastomosis in the frozen elephant trunk technique: initial experiences and preliminary results of arch zone 2 versus arch zone 3†. Eur J Cardiothorac Surg 2019; 56 (03) 564-571
  • 2 Kuroda Y, Uchida T, Ohba E. et al. Aortic remodelling effect of the frozen elephant trunk technique on Stanford type A acute aortic dissection. Interact Cardiovasc Thorac Surg 2021; 32 (05) 789-791
  • 3 Fujii M, Watanabe H, Otsu M, Sugahara Y. Incorrect frozen elephant trunk deployment into the false lumen of a patient with complicated type B acute dissection. Eur J Cardiothorac Surg 2019; 55 (06) 1222-1224
  • 4 Tamai K, Hori D, Yuri K, Yamaguchi A. Additional frozen elephant trunk as a bailout for a misdeployed frozen elephant trunk in the false lumen in a patient with acute aortic dissection. Eur J Cardiothorac Surg 2020; 57 (02) 399-401
  • 5 Plotkin A, Hanks SE, Han SM, Fleischman F, Weaver FA, Magee GA. Endovascular septal fenestration using a radiofrequency wire to salvage inadvertent false lumen deployment of a frozen elephant trunk stent graft. J Vasc Surg Cases Innov Tech 2019; 5 (04) 553-556
  • 6 Kawashima M, Nomura Y, Matsumori M, Murakami H. Bail-out thoracic endovascular aortic repair for incorrect deployment of frozen elephant trunk into the false lumen. Interact Cardiovasc Thorac Surg 2020; 30 (06) 947-949
  • 7 Preventza O, Liao JL, Olive JK. et al. Neurologic complications after the frozen elephant trunk procedure: a meta-analysis of more than 3000 patients. J Thorac Cardiovasc Surg 2020; 160 (01) 20-33.e4