Int J Sports Med 2017; 38(04): 300-306
DOI: 10.1055/s-0042-122818
Training & Testing
© Georg Thieme Verlag KG Stuttgart · New York

Reliability and Validity of a Self-paced Cardiopulmonary Exercise Test in Post-MI Patients

Lauren Ann Jenkins
1   School of Sport and Exercise Sciences, University of Kent, Chatham, United Kingdom of Great Britain and Northern Ireland
,
Alexis Mauger
1   School of Sport and Exercise Sciences, University of Kent, Chatham, United Kingdom of Great Britain and Northern Ireland
,
Jane Fisher
2   Cardiology, East Kent Hospitals University NHS Foundation Trust, Canterbury, United Kingdom of Great Britain and Northern Ireland
,
James Hopker
3   School of Sport and Exercise Sciences, University of Kent, Medway, United Kingdom of Great Britain and Northern Ireland
› Author Affiliations
Further Information

Publication History



accepted after revision 03 October 2016

Publication Date:
20 February 2017 (online)

Abstract

A self-paced peak oxygen uptake (V̇O2peak) test (SPV) has been shown to produce higher V̇O2peak values compared to standard cardiopulmonary exercise tests (sCPET), but has not been tested on any clinical population. This study aimed to assess the reliability of the SPV in a healthy population (study 1), and the validity and reliability of the SPV in post-myocardial infarction (post-MI) patients (study 2). For study 1, 25 healthy participants completed 3 SPV’s. For study 2, 28 post-MI patients completed one sCPET and 2 SPV’s. The SPV consisted of 5×2-min stages where participants were able to self-regulate their effort by using incremental ‘clamps’ in ratings of perceived exertion. The sCPET consisted of a 20 W/min ramp. Results demonstrated the SPV to have a coefficient of variation for V̇O2peak of 4.7% for the healthy population, and 8.2% for the post-MI patients. Limits of agreement ranged between±4.22–5.86 ml·kg−1·min−1, with the intraclass correlation coefficient ranging between 0.89–0.95. In study 2, there was a significantly higher V̇O2peak achieved in the SPV (23.07±4.90 ml·kg−1·min−1) against the sCPET (21.29±4.93 ml·kg−1·min−1). It is concluded that these results provide initial evidence that the SPV may be a safe, valid and reliable method for determining exercise capacity in post-MI patients.

 
  • References

  • 1 Albouaini K, Egred M, Alahmar A, Wright DJ. Cardiopulmonary exercise testing and its application. Heart 2007; 93: 1285-1292
  • 2 Astorino TA. Discussion: The efficacy of the self-paced VO2max test to measure maximal oxygen uptake in treadmill running. Appl Physiol Nutr Metab 2014; 39: 592-593
  • 3 Astorino TA, McMillan DW, Edmunds RM, Sanchez E. Increased cardiac output elicits higher VO2max in response to self-paced exercise. Appl Physiol Nutr Metab 2015; 40: 223-229
  • 4 Astorino TA, Rietschel JC, Tam PA, Taylor K, Johnson SM, Freedman TP, Sakarya CE. Reinvestigation of optimal duration of VO2max testing. J Exerc Physiol 2004; 7: 1-8
  • 5 Atkinson G, Nevill AM. Statistical methods for assessing measurement effort (reliability) in variables relevant to sports medicine. Sports Med 1998; 26: 217-238
  • 6 Balady GJ, Arena R, Sietsema K, Myers J, Coke L, Fletcher GF, Forman D, Franklin B, Guazzi M, Gulati M, Keteyian SJ, Lavie CJ, Macko R, Mancini D, Milani RV. . Clinician’s Guide to Cardiopulmonary Exercise Testing in Adults: A Scientific Statement From the American Heart Association. Circulation 2010; 122: 191-225
  • 7 Basset D, Howley ET. Limiting factors for maximum oxygen uptake and determinants of endurance performance. Med Sci Sports Exerc 2000; 32: 70-84
  • 8 Beckles MA, Spiro SG, Colice GL, Rudd RM. The physiologic evaluation of patients with lung cancer being considered for resectional surgery. Chest 2003; 123: 105-114
  • 9 Bland MJ, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307-310
  • 10 Brutsche MH, Spiliopoulos A, Bolliger CT, Licker M, Frey JG, Tschopp JM. Exercise capacity and extent of resection as predictors of surgical risk in lung cancer. Eur Respir J 2000; 15: 828-832
  • 11 Buchfuhrer MJ, Hansen JE, Robinson TE, Sue DY, Wasserman K, Whipp DJ. Optimizing the exercise protocol for cardiopulmonary assessment. J Appl Physiol 1983; 55: 1558-1564
  • 12 Buys R, Cornelissen V, Van De Bruaene A, Stevens A, Coeckelberghs E, Onkelinx S, Thomaes T, Delecluse C, Budts W, Venhees L. Measures of exercise capacity in adults with congenital heart disease. Int J Cardiol 2011; 153: 30
  • 13 Chidnok W, DiMenna FJ, Bailey SJ, Burnley M, Wilkerson DP, Vanhatalo A, Jones AM. VO2max is not altered by self-pacing during incremental exercise. Eur J Appl Physiol 2013; 113: 529-539
  • 14 Cox NJM, Hendrink JCM, Binkhorst RA, Folgering HTM, van Herwaarden CLA. Reproducibility of incremental maximal cycle ergometer tests in patients with mild to moderate obstructive lung disease. Lung 1989; 167: 129-133
  • 15 Davidson DM, DeBusk RF. Prognostic value of a single exercise test 3 weeks after uncomplicated myocardial infarction. Circulation 1980; 61: 236-242
  • 16 Eindhoven JA, van den Bosch AE, Oemrawsingh RM, Baggen VJ, Kardys I, Cuypers JA, Witsenburg M, van Schaik RH, Roos-Hesselink JW, Boersma E. Release of growth-differentiation factor 15 and associations with cardiac function in adult patients with congenital heart disease. Int J Cardiol 2016; 202: 246-251
  • 17 Eston RG, Crockett A, Jones AM. Discussion of: The efficacy of the self-paced V˙ O2max test to measure maximal oxygen uptake in treadmill running. Appl Physiol Nutr Metab 2014; 39: 581-582
  • 18 Faulkner J, Mauger AR, Woolley B, Lambrick DM. The efficacy of a self-paced VO2max test during motorized treadmill exercise. Int J Sports Physiol Perform 2015; 10: 99-105
  • 19 Froelicher VF, Brammell H, Davis G, Noguera I, Stewart A, Lancaster MC. A comparison of the reproducibility and physiologic response to three maximal treadmill exercise protocols. Chest 1974; 65: 512-517
  • 20 Gitt AK, Wasserman K, Kilkowski C, Kleemann T, Kilkowski A, Bangert M, Schneider S, Schwarz A, Senges J. Exercise anaerobic threshold and ventilator efficiency identify heart failure patients for high risk of early death. Circulation 2002; 106: 3079-3084
  • 21 Harriss DJ, Atkinson G. Ethical standards in sport and exercise science research: 2016 update. Int J Sports Med 2015; 36: 1121-1124
  • 22 Hogg JS, Hopker JG, Mauger AR. The self-paced VO2max test to assess maximal oxygen uptake in highly trained runners. Int J Sports Physiol Perform 2014; 10: 172-177
  • 23 Hopker JG, Jobson SA, Pandit JJ. Controversies in the physiological basis of the ‘anaerobic threshold’ and their implications for clinical cardiopulmonary exercise testing. Anaesthesia 2011; 66: 111-123
  • 24 Hopkins WG. Measures of reliability in sports medicine and science. Sports Med 2000; 30: 1-15
  • 25 Janicki JS, Gupta S, Ferris ST, McElroy PA. Long-term reproducibility of respiratory gas exchange measurements during exercise in patients with stable cardiac failure. Chest 1990; 97: 12-17
  • 26 Kahaly GJ, Wagner S, Nieswandt J, Mohr-Kahaly S, Ryan TJ. Stress echocardiography in hyperthyroidism. J Clin Endocrinol Metab 1999; 84: 2308-2313
  • 27 Kanthan A, Tan TC, Zecchin RP, Denniss AR. Early exercise stress testing is safe after primary percutaneious coronary intervention. Eur Heart J Acute Cardiovasc Care 2012; 1: 153-157
  • 28 Kothmann E, Danjoux G, Owen SJ, Parry A, Turley AJ, Batterham AM. Reliability of the anaerobic threshold in cardiopulmonary exercise testing of patients with abdominal aortic aneurysms. Anaesthesia 2009; 64: 9-13
  • 29 Kristensen SD, Knuuti J, Saraste A, Anker S, Botker HE, Hert SD, Ford I, Gonzalez-Juanatey JR, Gorenek B, Heyndrickx GR, Hoeft A, Huber K, Lung B, Kjeldsen KP, Longrois D, Luscher TF, Pierard L, Pocock S, Price S, Roffi M, Sirnes PA, Sousa-Uva M, Voudris V, Funck-Bentano C. 2014 ESC/ESA Guidelines on non-cardiac surgery: cardiovascular assessment and management. Eur Heart J 2014; 35: 2383-2431
  • 30 Lander PJ, Butterly RJ, Edwards AM. Self-paced exercise is less physically challenging than enforced constant pace exercise of the same intensity: influence of complex central metabolic control. Br J Sports Med 2009; 43: 789-795
  • 31 Marciniuk DD, Watts RE, Gallagher CG. Reproducibility of incremental maximal cycle ergometer testing in patients with restrictive lung disease. Thorax 1993; 48: 894-898
  • 32 Markiewicz W, Houston N, DeBusk RF. Exercise testing soon after myocardial infarction. Circulation 1977; 56: 26-31
  • 33 Mauger AR, Jones AM, Williams GA. Influence of feedback and prior experience on pacing during a 4-km cycle time trial. Med Sci Sports Exerc 2009; 41: 451-458
  • 34 Mauger AR, Metcalfe AJ, Taylor L, Castle PC. The efficacy of the self-paced VO2max test to measure maximal oxygen uptake in treadmill running. Appl Physiol Nutr Metab 2013; 38: 1211-1216
  • 35 Mauger AR, Metcalfe AJ, Taylor L, Castle PC. Reply to “Discussion: Efficacy of the self-paced VO2max test to measure maximal oxygen uptake in treadmill running”. Appl Physiol Nutr Metab 2014; 39: 583-585
  • 36 Mauger AR, Sculthorpe N. A new VO2max protocol allowing self-pacing in maximal incremental exercise. Br J Sports Med 2012; 46: 59-63
  • 37 McKone EF, Barry SC, FitzGerald MX, Gallagher CG. Reproducibility of maximal exercise ergometer testing in patients with cystic fibrosis. Chest 1999; 116: 363-368
  • 38 Myers J, Buchanan N, Walsh D, Kraemer M, McAuley P, Hamilton-Wessler M, Froelicher VF. Comparison of the ramp versus standard exercise protocols. JACC 1991; 17: 1334-1342
  • 39 Myers J, Prakash M, Froelicher V, Partington S, Atwood E. Exercise capacity and mortality among men referred for exercise testing. N Engl J Med 2002; 346: 793-801
  • 40 Myers J, Goldsmith RL, Keteyian SJ, Brawner CA, Brazil DA, Aldred H, Ehrman JK, Burkhoff D. The Ventilatory Anaerobic Threshold in Heart Failure: A Multicenter Evaluation of Reliability. J Card Fail 2010; 16: 76-83
  • 41 Noakes TD. Testing for maximum oxygen consumption has produced a brainless model of human exercise performance. Br J Sports Med 2008; 42: 551-555
  • 42 Older P, Hall A, Hader R. Cardiopulmonary exercise testing as a screening test for perioperative management of major surgery in the elderly. Chest 1999; 116: 355-362
  • 43 Poole DC. Discussion: “The efficacy of the self-paced V˙ O2max test to measure maximal oxygen uptake in treadmill running”. Appl Physiol Nutr Metab 2014; 39: 586-588
  • 44 Poole DC, Wilkerson DP, Jones AM. Validity of criteria for establishing maximal O2 uptake during ramp exercise tests. Eur J Appl Physiol 2008; 102: 403-410
  • 45 Reiser M, Meyer T, Kindermann W, Daugs R. Transferability of workload measurements between three difference types of ergometer. Eur J Appl Physiol 2000; 82: 245-249
  • 46 Roffi M, Wenaweser P, Windecker S, Mehta H, Eberli FR, Seiler C, Fleisch M, Garachemani A, Pedrazzini GB, Hess OM, Meier B. Early exercise after coronary stenting is safe. J Am Coll Cardiol 2003; 42: 1569-1573
  • 47 Straub AM, Midgley AW, Zarvorsky GS, Hillman AR. Ramp-incremented and RPE-clamped test protocols elicit similar VO2max values in trained cyclists. Eur J Appl Physiol 2014; 114: 1581-1590
  • 48 West M, Jack S, Grocott MPW. Perioperative cardiopulmonary exercise testing in the elderly. Best Pract Res Clin Anaesthesiol 2011; 25: 427-437
  • 49 Wilson RJT, Davies S, Yates D, Redman J, Stone M. Impaired functional capacity is associated with all-cause mortality after major elective intra-abdominal surgery. Br J Sports Med 2010; 105: 297-303