CC BY 4.0 · Journal of Child Science 2022; 12(01): e5-e8
DOI: 10.1055/s-0041-1741425
Original Article

Central Subclavian Catheterization in Newborns: Single-Center Experience

1   Department of Pediatrics, Oztan Hospital, Usak, Turkey
,
2   Department of Pediatric Surgery, Lokman Hekim Van Hospital, Van, Turkey
,
3   Department of Pediatrics, Lokman Hekim Van Hospital, Van, Turkey
› Author Affiliations

Abstract

Our main aim of this article was to show that central venous catheter (CVC) can be an easy-to-use, less-complicated catheter application such as peripherally inserted central catheter and umbilical catheter placement in the neonatal intensive care unit. We here described our experience with subclavian vein catheterization. Neonates who had venous access through subclavian central catheterization were assessed retrospectively. Data such as gestational age, age at the time of catheter insertion, birth weight, and gender were collected. In addition, problems related to catheterization during hospitalization were documented. This study comprised 40 newborns, 22 male and 18 female, with a mean gestational week of 29.57 ± 3.80 weeks and a mean gestational weight of 2067.50 ± 545.97 g. Due to occlusion, catheters were switched in five cases twice and in three cases once, totaling 53 catheterizations on 40 newborns. None of our patients had pneumothorax or hemothorax. On the postoperative 8th and 21st days, the catheter was withdrawn due to catheter infection in two (5%) patients, and catheter cultures revealed coagulase negative Staphylococcus aureus in both cases. Even in preterm infants, subclavian central venous catheterization is a safe and straightforward technique of gaining venous access in expert hands in the neonatal intensive care unit.



Publication History

Received: 10 November 2021

Accepted: 24 November 2021

Article published online:
18 February 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Crowley JJ. Vascular access. Tech Vasc Interv Radiol 2003; 6 (04) 176-181
  • 2 Janes M, Kalyn A, Pinelli J, Paes B. A randomized trial comparing peripherally inserted central venous catheters and peripheral intravenous catheters in infants with very low birth weight. J Pediatr Surg 2000; 35 (07) 1040-1044
  • 3 Stolfi I, Boccanera F, Chiara C. et al. Central venous lines and how to manage them. Early Hum Dev 2009; 85 (Suppl 10): S83-S84
  • 4 Yang ZM, Wang SN, Ma YL, Yang XL, Zhang WY, Zhu MY. [Application of umbilical venous catheter combined with peripherally inserted central catheter in very low birth weight infants]. Zhongguo Dang Dai Er Ke Za Zhi 2013; 15 (05) 353-355
  • 5 Shalabi M, Adel M, Yoon E, Aziz K, Lee S, Shah PS. Canadian Neonatal Network. Risk of infection using peripherally inserted central and umbilical catheters in preterm neonates. Pediatrics 2015; 136 (06) 1073-1079
  • 6 Kim JH, Lee YS, Kim SH, Lee SK, Lim MK, Kim HS. Does umbilical vein catheterization lead to portal venous thrombosis? Prospective US evaluation in 100 neonates. Radiology 2001; 219 (03) 645-650
  • 7 Butler-O'Hara M, D'Angio CT, Hoey H, Stevens TP. An evidence-based catheter bundle alters central venous catheter strategy in newborn infants. J Pediatr 2012; 160 (06) 972-7.e2
  • 8 Youn SH, Lee JC, Kim Y, Moon J, Choi Y, Jung K. Central venous catheter-related infection in severe trauma patients. World J Surg 2015; 39 (10) 2400-2406
  • 9 Finck C, Smith S, Jackson R, Wagner C. Percutaneous subclavian central venous catheterization in children younger than one year of age. Am Surg 2002; 68 (04) 401-404
  • 10 Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol 1953; 39 (05) 368-376
  • 11 Lausten-Thomsen U, Merchaoui Z, Dubois C. et al. Ultrasound-guided subclavian vein cannulation in low birth weight neonates. Pediatr Crit Care Med 2017; 18 (02) 172-175
  • 12 Guilbert AS, Xavier L, Ammouche C. et al. Supraclavicular ultrasound-guided catheterization of the subclavian vein in pediatric and neonatal ICUs: a feasibility study. Pediatr Crit Care Med 2013; 14 (04) 351-355
  • 13 Araujo CC, Lima MC, Falbo GH. Percutaneous subclavian central venous catheterization in children and adolescents: success, complications and related factors. J Pediatr (Rio J) 2007; 83 (01) 64-70
  • 14 García HJ, Torres-Yáñez HL. [Survival and complication rate of central venous catheters in newborns]. Rev Med Inst Mex Seguro Soc 2015; 53 (Suppl. 03) S300-S309
  • 15 Sheridan RL, Weber JM. Mechanical and infectious complications of central venous cannulation in children: lessons learned from a 10-year experience placing more than 1000 catheters. J Burn Care Res 2006; 27 (05) 713-718
  • 16 Urzedo JE, Levenhagen MM, Pedroso RS, Abdallah VO, Sabino SS, Brito DV. Nosocomial infections in a neonatal intensive care unit during 16 years: 1997-2012. Rev Soc Bras Med Trop 2014; 47 (03) 321-326
  • 17 Escobar GJ, Li DK, Armstrong MA. et al. Neonatal sepsis workups in infants >/=2000 grams at birth: a population-based study. Pediatrics 2000; 106 (2 Pt 1): 256-263
  • 18 de Almeida Silva H, Steffen Abdallah VO, Carneiro CL, Gontijo PP PP. Infection and colonization by Staphylococcus aureus in a high risk nursery of a Brazilian teaching hospital. Braz J Infect Dis 2003; 7 (06) 381-386
  • 19 Aslam N, Mehdi N, Izhar M. Root cause analysis of methicillin resistant Staphylococcus aureus bacteraemia. J Pak Med Assoc 2015; 65 (10) 1089-1093
  • 20 Kaji T, Kawano T, Yamada W. et al. The changing profile of safe techniques for the insertion of a central venous catheter in pediatric patients - improvement in the outcome with the experiences of 500 insertions in a single institution. J Pediatr Surg 2016; 51 (12) 2044-2047
  • 21 Greenberg RG, Cochran KM, Smith PB. et al. Effect of catheter dwell time on risk of central line-associated bloodstream infection in infants. Pediatrics 2015; 136 (06) 1080-1086
  • 22 Zingg W, Posfay-Barbe KM, Pfister RE, Touveneau S, Pittet D. Individualized catheter surveillance among neonates: a prospective, 8-year, single-center experience. Infect Control Hosp Epidemiol 2011; 32 (01) 42-49
  • 23 Smith PB, Benjamin Jr DK, Cotten CM. et al. Is an increased dwell time of a peripherally inserted catheter associated with an increased risk of bloodstream infection in infants?. Infect Control Hosp Epidemiol 2008; 29 (08) 749-753
  • 24 Yumani DF, van den Dungen FA, van Weissenbruch MM. Incidence and risk factors for catheter-associated bloodstream infections in neonatal intensive care. Acta Paediatr 2013; 102 (07) e293-e298
  • 25 Rangel UV, Gomes Junior SC, Costa AM, Moreira ME. Variables associated with peripherally inserted central catheter related infection in high risk newborn infants. Rev Lat Am Enfermagem 2014; 22 (05) 842-847
  • 26 Cheong SM, Totsu S, Nakanishi H, Uchiyama A, Kusuda S. Outcomes of peripherally inserted double lumen central catheter in very low birth weight infants. J Neonatal Perinatal Med 2016; 9 (01) 99-105