CC BY 4.0 · Eur J Dent 2022; 16(03): 663-668
DOI: 10.1055/s-0041-1739440
Original Article

Microtomographic Evaluation of Canal Centralization and Dentine Removal after Canal Preparation with Two Rotary Systems: HyFlex EDM and ProTaper Next

Vivian Ronquete
1   Department of Endodontics and Dental Research, Iguaçu University, Nova Iguaçu, Brazil
,
Alexandre Sigrist de Martin
2   Department of Endodontics, São Leopoldo Mandic University, Campinas, Brazil
,
Karin Zuim
2   Department of Endodontics, São Leopoldo Mandic University, Campinas, Brazil
,
Thais Machado de Carvalho Coutinho
1   Department of Endodontics and Dental Research, Iguaçu University, Nova Iguaçu, Brazil
,
Eduardo Fagury Videira Marceliano
3   Dental Clinic Department, Brazilian Army General Hospital of Belem, Belem, Brazil
,
Paula Avelar Da Silva Ribeiro Goulart
1   Department of Endodontics and Dental Research, Iguaçu University, Nova Iguaçu, Brazil
,
Ricardo Tadeu Lopes
4   Laboratory for Nuclear Instrumentation, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
,
Carlos Eduardo Da Silveira Bueno
2   Department of Endodontics, São Leopoldo Mandic University, Campinas, Brazil
,
Marília Fagury Videira Marceliano-Alves
1   Department of Endodontics and Dental Research, Iguaçu University, Nova Iguaçu, Brazil
› Author Affiliations

Abstract

Objective This study compared the ProTaper Next (PTN; Dentsply Sirona, Tulsa, Oklahoma, United States) and HyFlex EDM (HEDM; Coltene/Whaledent AG, Alstätten, Switzerland) systems using micro–computed tomography (CT).

Materials and Methods Twenty-one mesial roots classified as Vertucci's type IV from extracted mandibular first molars with curvatures between 20 and 40 degrees were selected. The teeth were scanned using a micro-CT before and after root canal preparation by both systems, applied to the same root, in alternating canals. The following parameters were analyzed: canal centering, apical transportation, root canal diameter/root diameter.

Results No statistically significant differences between both systems were observed for any of the assessed morphological parameters (p > 0.05). All canals presented diameter enlargement of more than 40% in relation to root diameter in the cervical and middle segments. No statistically significant difference was noted between the HEDM and PTN groups. The wear percentage for the HEDM group in the cervical and middle thirds were 49.66 ± 8.65 and 46.48 ± 14.29, respectively, and 51.02 ± 11.81 and 45.48 ± 10.79 for the PTN group, respectively.

Conclusion Both systems displayed similar mandibular molar mesial canals preparation, with no differences noted for any of the assessed parameters. Both groups showed increased canal diameter in the cervical and middle thirds by more than 40%.



Publication History

Article published online:
11 January 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Peters OA, Laib A, Göhring TN, Barbakow F. Changes in root canal geometry after preparation assessed by high-resolution computed tomography. J Endod 2001; 27 (01) 1-6
  • 2 Roane JB, Sabala CL, Duncanson Jr MG. The “balanced force” concept for instrumentation of curved canals. J Endod 1985; 11 (05) 203-211
  • 3 Peters OA, Peters CI, Basrani B. Cleaning and shaping the root canal system. In: Hargreaves KM, Berman LH. eds. Cohen's Pathways of the Pulp, 11th ed. St Louis: Elsevier; 2016
  • 4 Siqueira Jr JF, Lopes HP. Chemomechanical preparation. In: Siqueira Jr JF. ed. Treatment of Endodontic Infections. London, UK: Quintessence Publishing; 2011
  • 5 Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988; 14 (07) 346-351
  • 6 Alapati SB, Brantley WA, Iijima M. et al. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments. J Endod 2009; 35 (11) 1589-1593
  • 7 Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004; 30 (08) 559-567
  • 8 Yamamura B, Cox TC, Heddaya B, Flake NM, Johnson JD, Paranjpe A. Comparing canal transportation and centering ability of endo sequence and vortex rotary files by using micro–computed tomography. J Endod 2012; 38 (08) 1121-1125
  • 9 Gündoğar M, Özyürek T. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments. J Endod 2017; 43 (07) 1192-1196
  • 10 Pedullà E, Lo Savio F, Boninelli S. et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod 2016; 42 (01) 156-159
  • 11 The new NiTi file generation: HyFlex. 2015 . Accessed November 15, 2018 at: https://www.coltene.com/fileadmin/Data/EN/Products/Endodontics/Root_Canal_Shaping/HyFlex_EDM/31328A_HyFlexEDM_Brochure_US.pdf
  • 12 Ye J, Gao Y. Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue. J Endod 2012; 38 (01) 105-107
  • 13 Moore J, Fitz-Walter P, Parashos P. A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques. Int Endod J 2009; 42 (12) 1057-1064
  • 14 da Silva Limoeiro AG, Dos Santos AH, De Martin AS. et al. Micro-computed tomographic evaluation of 2 nickel-titanium instrument systems in shaping root canals. J Endod 2016; 42 (03) 496-499
  • 15 Wilcox LR, Roskelley C, Sutton T. The relationship of root canal enlargement to finger-spreader induced vertical root fracture. J Endod 1997; 23 (08) 533-534
  • 16 Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971; 32 (02) 271-275
  • 17 Çalt S, Serper A. Time-dependent effects of EDTA on dentin structures. J Endod 2002; 28 (01) 17-19
  • 18 Clegg MS, Vertucci FJ, Walker C, Belanger M, Britto LR. The effect of exposure to irrigant solutions on apical dentin biofilms in vitro. J Endod 2006; 32 (05) 434-437
  • 19 Stojicic S, Zivkovic S, Qian W, Zhang H, Haapasalo M. Tissue dissolution by sodium hypochlorite: effect of concentration, temperature, agitation, and surfactant. J Endod 2010; 36 (09) 1558-1562
  • 20 Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod 1996; 22 (07) 369-375
  • 21 Brasil SC, Marceliano-Alves MF, Marques ML. et al. Canal transportation, unprepared areas, and dentin removal after preparation with BT-RaCe and ProTaper Next systems. J Endod 2017; 43 (10) 1683-1687
  • 22 Hülsmann M, Peters OA, Dummer PMH. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 2005; 10: 30-76
  • 23 Gagliardi J, Versiani MA, de Sousa-Neto MD, Plazas-Garzon A, Basrani B. Evaluation of the shaping characteristics of ProTaper Gold, ProTaper Next, and ProTaper Universal in curved canals. J Endod 2015; 41 (10) 1718-1724
  • 24 Kishen A. Mechanisms and risk factors for fracture predilection in endodontically treated teeth. Endod Topics 2006; 13: 57-83
  • 25 Tang W, Wu Y, Smales RJ. Identifying and reducing risks for potential fractures in endodontically treated teeth. J Endod 2010; 36 (04) 609-617
  • 26 Siqueira Jr JF, Elias CN, Lopes HP. Instrumentos Endodônticos. In: Endodontia Biologia e Técnica. 3° Edição. Rio de Janeiro: Editora Guanabara Koogan; 2010: 305-413
  • 27 Duque JA, Vivan RR, Cavenago BC. et al. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems. J Appl Oral Sci 2017; 25 (01) 27-33
  • 28 You SY, Kim HC, Bae KS, Baek SH, Kum KY, Lee W. Shaping ability of reciprocating motion in curved root canals: a comparative study with micro-computed tomography. J Endod 2011; 37 (09) 1296-1300
  • 29 Kim HC, Hwang YJ, Jung DW, You SY, Kim HC, Lee W. Micro-computed tomography and scanning electron microscopy comparisons of two nickel–titanium rotary root canal instruments used with reciprocating motion. Scanning 2013; 35 (02) 112-118
  • 30 Gergi R, Rjeily JA, Sader J, Naaman A. Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography. J Endod 2010; 36 (05) 904-907