Int J Angiol 2022; 31(01): 052-055
DOI: 10.1055/s-0041-1735237
Rapid Communication

Laser Doppler Measurements of Systolic Blood Pressure on the First and Second Toe in Patients with Peripheral Arterial Disease

1   Department of Clinical Physiology, Södersjukhuset, Stockholm, Sweden
2   Department of Clinical Science and Education, Karolinska Institutet, Stockholm, Sweden
,
Agnes Modin
1   Department of Clinical Physiology, Södersjukhuset, Stockholm, Sweden
,
Johan Petrini
1   Department of Clinical Physiology, Södersjukhuset, Stockholm, Sweden
3   Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
› Author Affiliations

Abstract

Laser Doppler was used to measure toe blood pressure (TBP) in 40 consecutive patients with various degree of peripheral arterial disease. The aim of this methodological study was to increase the usefulness of TBP by exploring the interchangeability between TBP from the first and second toe and by investigating daily routine reproducibility and measurement variability. According to our study design pressure values were based on three measurements that were averaged. At simultaneous measurements, TBP of the first toe was 71 mm Hg (standard deviation [SD] 25) compared with 70 mm Hg (SD 25) on the second toe. The correlation (r) between first and second toe pressure measurements was 0.84 and intraclass correlation coefficient (ICC) was 0.84. The difference between TBP on the first and second toe was not related to gender, diabetes, or magnitude of the pressures. Repeated TBP measurements of the right first toe after disconnection of cuffs, 5 to 10 minutes rest, and reconnection of cuffs had a coefficient of variation (CV) of 9% and an ICC of 0.93. CV for toe-brachial index (TBI) was 8%. Our results show that measurements of TBP from the second toe to a large extent are interchangeable with those assessed from the first toe and can be used in clinical situations where measurements from the first toe are not feasible. Flow detection with three averaged laser Doppler measurements generates TBP and TBI with low variability.



Publication History

Article published online:
21 September 2021

© 2021. International College of Angiology. This article is published by Thieme.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Mills Sr JL, Conte MS, Armstrong DG. et al; Society for Vascular Surgery Lower Extremity Guidelines Committee. The Society for Vascular Surgery Lower Extremity Threatened Limb Classification System: risk stratification based on wound, ischemia, and foot infection (WIfI). J Vasc Surg 2014; 59 (01) 220-34.e1 , 2
  • 2 Aboyans V, Ricco J-B, Bartelink MEL. et al; ESC Scientific Document Group. 2017 ESC guidelines on the diagnosis and treatment of peripheral arterial diseases, in collaboration with the European Society for Vascular Surgery (ESVS). Eur Heart J 2018; 39 (09) 763-816
  • 3 Goss DE, de Trafford J, Roberts VC, Flynn MD, Edmonds ME, Watkins PJ. Raised ankle/brachial pressure index in insulin-treated diabetic patients. Diabet Med 1989; 6 (07) 576-578
  • 4 Andersson S, Linderholm H, Rinnström O, Burlin L. A laser Doppler technique for measuring distal blood-pressure: a comparison with conventional strain-gauge technique. Clin Physiol 1986; 6 (04) 329-335
  • 5 de Graaff JC, Ubbink DT, Legemate DA, de Haan RJ, Jacobs MJHM. The usefulness of a laser Doppler in the measurement of toe blood pressures. J Vasc Surg 2000; 32 (06) 1172-1179
  • 6 Høyer C, Sandermann J, Petersen LJ. The toe-brachial index in the diagnosis of peripheral arterial disease. J Vasc Surg 2013; 58 (01) 231-238
  • 7 Fleiss JL. The Design and Analysis of Clinical Experiments. New York: John Wiley; 1986: 1-32
  • 8 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1 (8476): 307-310
  • 9 Ubbink DT. Toe blood pressure measurements in patients suspected of leg ischaemia: a new laser Doppler device compared with photoplethysmography. Eur J Vasc Endovasc Surg 2004; 27 (06) 629-634
  • 10 Sahli D, Svensson M, Lidgren J, Öjbrandt K, Eriksson JW. Evaluation of simple non-invasive techniques for assessment of lower extremity arterial disease. Clin Physiol Funct Imaging 2005; 25 (03) 129-134
  • 11 Bhamidipaty V, Dean A, Yap SL. et al. Second toe systolic pressure measurements are valid substitutes for first toe systolic pressure measurements in diabetic patients: a prospective study. Eur J Vasc Endovasc Surg 2015; 49 (01) 77-82
  • 12 Watanabe Y, Masaki H, Kojima K, Tanemoto K. Toe-brachial index in the second toe: substitutability to toe-brachial index in the great toe and ankle-brachial index. Ann Vasc Dis 2016; 9 (04) 300-306