Subscribe to RSS

DOI: 10.1055/s-0041-1731863
Advances in Environmental Detection and Clinical Diagnostic Tests for Legionella Species
Authors
Abstract
Legionella is a fastidious organism that is difficult to culture in the lab but is widely distributed in environmental, domestic, and hospital settings. The clinical manifestations due to Legionella infections range from mild fever to fatal pneumonia and multiorgan pathologies. Legionella outbreaks though prevalent globally are not reported in developing countries due to difficulties in isolating this organism and the lack of simple diagnostic protocols. Here, we review the literature from across countries to present various methods used to detect Legionella from environmental and clinical samples. We compare the sensitivity and the specificity of the conventional culture-based assays with the recent methods and discuss approaches to develop better detection and diagnostic tests. With better cost-effective detection techniques and regular monitoring of the susceptible sites, which may harbor Legionella colonies, most of the Legionella infections can be prevented. As a result, considerable burden, caused by Legionella infections, on the healthcare system, in especially economically weaker countries, can be mitigated.
Keywords
extrapulmonary infection - iron - Legionella - Legionella-contaminated aerosol - Legionnaires diseases - Pontiac fever - water distribution systemPublication History
Article published online:
30 July 2021
© 2021. Nitte (Deemed to be University). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Mercante JW, Winchell JM. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clin Microbiol Rev 2015; 28 (01) 95-133
- 2 Newton HJ, Ang DK, van Driel IR, Hartland EL. Molecular pathogenesis of infections caused by Legionella pneumophila. Clin Microbiol Rev 2010; 23 (02) 274-298
- 3 Fields BS, Benson RF, Besser RE. Legionella and Legionnaires' disease: 25 years of investigation. Clin Microbiol Rev 2002; 15 (03) 506-526
- 4 Mekkour M, Khalil E, Driss B, Tai J, Cohen N. Legionella pneumophila: an environmental organism and accidental pathogen. Int J Sci Technol 2013; 2 (02) 187-196
- 5 Colbourne JS, Dennis PJ, Trew RM, Berry C, Vesey G. Legionella and public water supplies. Water Sci Technol 1988; 20 (11-12) 5-10
- 6 Fliermans CB, Cherry WB, Orrison LH, Smith SJ, Tison DL, Pope DH. Ecological distribution of Legionella pneumophila. Appl Environ Microbiol 1981; 41 (01) 9-16
- 7 Hoge CW, Breiman RF. Advances in the epidemiology and control of Legionella infections. Epidemiol Rev 1991; 13 (01) 329-340
- 8 Steinert M, Hentschel U, Hacker J. Legionella pneumophila: an aquatic microbe goes astray. FEMS Microbiol Rev 2002; 26 (02) 149-162
- 9 Heng BH, Goh KT, Ng DL, Ling AE. Surveillance of legionellosis and Legionella bacteria in the built environment in Singapore. Ann Acad Med Singap 1997; 26 (05) 557-565
- 10 Leoni E, Legnani PP, Bucci Sabattini MA, Righi F. Prevalence of Legionella spp. in swimming pool environment. Water Res 2001; 35 (15) 3749-3753
- 11 Atlas RM. Legionella: from environmental habitats to disease pathology, detection and control. Environ Microbiol 1999; 1 (04) 283-293
- 12 Bollin GE, Plouffe JF, Para MF, Hackman B. Aerosols containing Legionella pneumophila generated by shower heads and hot-water faucets. Appl Environ Microbiol 1985; 50 (05) 1128-1131
- 13 Chaudhry R, Sreenath K, Arvind V, Vinayaraj EV, Tanu S. Legionella pneumophila serogroup 1 in the water facilities of a tertiary healthcare center, India. Emerg Infect Dis 2017; 23 (11) 1924-1925
- 14 Jinna S, Gaikwad UN. Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis. Indian J Med Res 2018; 147 (06) 611-614
- 15 Burillo A, Pedro-Botet ML, Bouza E. Microbiology and epidemiology of Legionnaire's disease. Infect Dis Clin North Am 2017; 31 (01) 7-27
- 16 Cassell K, Davis JL, Berkelman R. Legionnaires' disease in the time of COVID-19. Pneumonia (Nathan) 2021; 13 (01) 2
- 17 Palazzolo C, Maffongelli G, D'Abramo A. et al. Legionella pneumonia: increased risk after COVID-19 lockdown? Italy, May to June 2020. Euro Surveill 2020; 25 (30) 2001372
- 18 Rota MC, Scaturro M, Ricci ML. Letter to the editor: importance of a careful investigation to avoid attributing Legionnaires' disease cases to an incorrect source of infection. Euro Surveill 2020; 25 (34) 2001484
- 19 Boshuizen HC, Neppelenbroek SE, van Vliet H. et al. Subclinical Legionella infection in workers near the source of a large outbreak of Legionnaires disease. J Infect Dis 2001; 184 (04) 515-518
- 20 Nagelkerke NJ, Boshuizen HC, de Melker HE, Schellekens JF, Peeters MF, Conyn-van Spaendonck M. Estimating the incidence of subclinical infections with Legionella Pneumonia using data augmentation: analysis of an outbreak in The Netherlands. Stat Med 2003; 22 (24) 3713-3724
- 21 Amodeo MR, Murdoch DR, Pithie AD. Legionnaires' disease caused by Legionella longbeachae and Legionella pneumophila: comparison of clinical features, host-related risk factors, and outcomes. Clin Microbiol Infect 2010; 16 (09) 1405-1407
- 22 WHO G. Guidelines for drinking-water quality. World Health Organization 2011; 216:303–304. Available at: https://apps.who.int/iris/bitstream/handle/10665/44584/9789241548151_eng.pdf;jsessionid=30C418A2B8231AFBCA0956BC8989DCF9?sequence=1 (Accessed on 12 May 2021)
- 23 Chidiac C, Che D, Pires-Cronenberger S. et al. French Legionnaires' Disease Study Group. Factors associated with hospital mortality in community-acquired legionellosis in France. Eur Respir J 2012; 39 (04) 963-970
- 24 Mulazimoglu L, Yu VL. Can Legionnaires disease be diagnosed by clinical criteria? A critical review. Chest 2001; 120 (04) 1049-1053
- 25 Jespersen S, Søgaard OS, Schønheyder HC, Fine MJ, Østergaard L. Clinical features and predictors of mortality in admitted patients with community- and hospital-acquired legionellosis: a Danish historical cohort study. BMC Infect Dis 2010; 10 (01) 124
- 26 Pancer K, Stypułkowska-Misiurewicz H. [Pontiac fever–non-pneumonic legionellosis]. Przegl Epidemiol 2003; 57 (04) 607-612
- 27 Fields BS, Haupt T, Davis JP, Arduino MJ, Miller PH, Butler JC. Pontiac fever due to Legionella micdadei from a whirlpool spa: possible role of bacterial endotoxin. J Infect Dis 2001; 184 (10) 1289-1292
- 28 Castor ML, Wagstrom EA, Danila RN. et al. An outbreak of Pontiac fever with respiratory distress among workers performing high-pressure cleaning at a sugar-beet processing plant. J Infect Dis 2005; 191 (09) 1530-1537
- 29 Avril JL, Dabernat H, Denis F, Monteil H. Epidémiologie et pouvoir pathogène de Legionella. In: Bactériologie Clinique Edited by: Ellipses. Paris: 1992: 309-18
- 30 Friedman S, Spitalny K, Barbaree J, Faur Y, McKinney R. Pontiac fever outbreak associated with a cooling tower. Am J Public Health 1987; 77 (05) 568-572
- 31 Lowry PW, Tompkins LS. Nosocomial legionellosis: a review of pulmonary and extrapulmonary syndromes. Am J Infect Control 1993; 21 (01) 21-27
- 32 Stout JE, Yu VL, Muraca P. Isolation of Legionella pneumophila from the cold water of hospital ice machines: implications for origin and transmission of the organism. Infect Control 1985; 6 (04) 141-146
- 33 Eitrem R, Forsgren A, Nilsson C. Pneumonia and acute pancreatitis most probably caused by a Legionella longbeachae infection. Scand J Infect Dis 1987; 19 (03) 381-382
- 34 Shelburne SA, Kielhofner MA, Tiwari PS. Cerebellar involvement in legionellosis. South Med J 2004; 97 (01) 61-64
- 35 Phin N, Parry-Ford F, Harrison T. et al. Epidemiology and clinical management of Legionnaires' disease. Lancet Infect Dis 2014; 14 (10) 1011-1021
- 36 Ozerol IH, Bayraktar M, Cizmeci Z. et al. Legionnaire's disease: a nosocomial outbreak in Turkey. J Hosp Infect 2006; 62 (01) 50-57
- 37 Garrison LE, Kunz JM, Cooley LA. et al. Vital signs: deficiencies in environmental control identified in outbreaks of Legionnaires' disease—North America, 2000-2014. MMWR Morb Mortal Wkly Rep 2016; 65 (22) 576-584
- 38 Zemouri C, Awad SF, Volgenant CM. Crielaard W, Laheij AMGA, de Soet JJ. Modeling of the transmission of coronaviruses, measles virus, influenza virus, Mycobacterium tuberculosis, and Legionella pneumophila in dental clinics. J Dent Res 2020; 99 (10) 1192-1198
- 39 Sreenath K, Dey AB, Kabra SK, Thakur B, Guleria R, Chaudhry R. Legionella pneumophila in patients with pneumonia at a referral hospital, New Delhi, India, 2015-2020. Am J Trop Med Hyg 2020; 14: tpmd-200653
- 40 Cherry WB, Pittman B, Harris PP. et al. Detection of Legionnaires disease bacteria by direct immunofluorescent staining. J Clin Microbiol 1978; 8 (03) 329-338
- 41 Berdal BP, Farshy CE, Feeley JC. Detection of Legionella pneumonophila antigen in urine by enzyme-linked immunospecific assay. J Clin Microbiol 1979; 9 (05) 575-578
- 42 Villari P, Motti E, Farullo C, Torre I. Comparison of conventional culture and PCR methods for the detection of Legionella pneumophila in water. Lett Appl Microbiol 1998; 27 (02) 106-110
- 43 Fields BS. The molecular ecology of legionellae. Trends Microbiol 1996; 4 (07) 286-290
- 44 Delgado-Viscogliosi P, Simonart T, Parent V. et al. Rapid method for enumeration of viable Legionella pneumophila and other Legionella spp. in water. Appl Environ Microbiol 2005; 71 (07) 4086-4096
- 45 Cirillo JD, Falkow S, Tompkins LS. Growth of Legionella pneumophila in Acanthamoeba castellanii enhances invasion. Infect Immun 1994; 62 (08) 3254-3261
- 46 Aurell H, Catala P, Farge P. et al. Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry. Appl Environ Microbiol 2004; 70 (03) 1651-1657
- 47 Hay J, Seal DV, Billcliffe B, Freer JH. Non-culturable Legionella pneumophila associated with Acanthamoeba castellanii: detection of the bacterium using DNA amplification and hybridization. J Appl Bacteriol 1995; 78 (01) 61-65
- 48 Cloud JL, Carroll KC, Pixton P, Erali M, Hillyard DR. Detection of Legionella species in respiratory specimens using PCR with sequencing confirmation. J Clin Microbiol 2000; 38 (05) 1709-1712
- 49 Grattard F, Ginevra C, Riffard S. et al. Analysis of the genetic diversity of Legionella by sequencing the 23S-5S ribosomal intergenic spacer region: from phylogeny to direct identification of isolates at the species level from clinical specimens. Microbes Infect 2006; 8 (01) 73-83
- 50 Blanco S, Prat C, Sánchez MD. et al. Evaluation of a Legionella urinary antigen enzyme immunoassay for rapid detection of Legionella pneumophila in water samples. Int J Hyg Environ Health 2008; 211 (01/02) 168-171
- 51 Parthuisot N, Binet M, Touron-Bodilis A, Pougnard C, Lebaron P, Baudart J. Total and viable Legionella pneumophila cells in hot and natural waters as measured by immunofluorescence-based assays and solid-phase cytometry. Appl Environ Microbiol 2011; 77 (17) 6225-6232
- 52 Whiley H, Taylor M. Legionella detection by culture and qPCR: comparing apples and oranges. Crit Rev Microbiol 2016; 42 (01) 65-74
- 53 Brooks T, Osicki R, Springthorpe V. et al. Detection and identification of Legionella species from groundwaters. J Toxicol Environ Health A 2004; 67 (20/22) 1845-1859
- 54 Lizana X, López A, Benito S. et al. Viability qPCR, a new tool for Legionella risk management. Int J Hyg Environ Health 2017; 220 (08) 1318-1324
- 55 Moosavian M, Seyed-Mohammadi S, Saki M. et al. Loop-mediated isothermal amplification for detection of Legionella pneumophila in respiratory specimens of hospitalized patients in Ahvaz, southwest Iran. Infect Drug Resist 2019; 12: 529-534
- 56 Olabarria G, Eletxigerra U, Rodriguez I, Bilbao A, Berganza J, Merino S. Highly sensitive and fast Legionella spp. in situ detection based on a loop mediated isothermal amplification technique combined to an electrochemical transduction system. Talanta 2020; 217: 121061
- 57 Reuter C, Slesiona N, Hentschel S. et al. Loop-mediated amplification as promising on-site detection approach for Legionella pneumophila and Legionella spp. Appl Microbiol Biotechnol 2020; 104 (01) 405-415
- 58 Kersting S, Rausch V, Bier FF, von Nickisch-Rosenegk M. A recombinase polymerase amplification assay for the diagnosis of atypical pneumonia. Anal Biochem 2018; 550: 54-60
- 59 Kuroki T, Watanabe Y, Teranishi H, Izumiyama S, Amemura-Maekawa J, Kura F. Legionella prevalence and risk of legionellosis in Japanese households. Epidemiol Infect 2017; 145 (07) 1398-1408
- 60 Samhan FA, Stedtfeld TM, Waseem H, Williams MR, Stedtfeld RD, Hashsham SA. On-filter direct amplification of Legionella pneumophila for rapid assessment of its abundance and viability. Water Res 2017; 121: 162-170
- 61 Lu X, Mo ZY, Zhao HB, Yan H, Shi L. LAMP-based method for a rapid identification of Legionella spp. and Legionella pneumophila. Appl Microbiol Biotechnol 2011; 92 (01) 179-187
- 62 Annaka T. Rapid and simple detection of Legionella species by LAMP, a mew DNA amplification method. Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM. J Rapid Meth Aut Mic. 2003; 14 (01) 25-30
- 63 Croxatto A, Prod'hom G, Greub G. Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology. FEMS Microbiol Rev 2012; 36 (02) 380-407
- 64 Dilger T, Melzl H, Gessner A. Rapid and reliable identification of waterborne Legionella species by MALDI-TOF mass spectrometry. J Microbiol Methods 2016; 127: 154-159
- 65 Stout JE, Rihs JD, Yu VL. Legionella. In: Murray PR, Baron EJ, eds. Manual of Clinical Microbiology. 8th ed. Washington DC:. ASM Press; 2003; 809-823
- 66 Dionne M, Hatchette T, Forward K. Clinical utility of a Legionella pneumophila urinary antigen test in a large university teaching hospital. Can J Infect Dis 2003; 14 (02) 85-88
- 67 Sampson JS, Wilkinson HW, Tsang VC, Brake BJ. Kinetic-dependent enzyme-linked immunosorbent assay for detection of antibodies to Legionella pneumophila. J Clin Microbiol 1983; 18 (06) 1340-1344
- 68 Sun H, Ma H, Liu L, Cao X, Yang Z. A new ELISA method for serological diagnosis of Legionella pneumophila: use of five purified proteins, FLA, MOMP, MIP, IP, and PILE, as diagnostic antigen. Clin Lab 2015; 61 (3-4) 275-282
- 69 Benowitz I, Fitzhenry R, Boyd C. et al. Rapid identification of a cooling tower-associated legionnaires' disease outbreak supported by polymerase chain reaction testing of environmental samples, New York City, 2014-2015. J Environ Health 2018; 80 (08) 8-12
- 70 van der Lugt W, Euser SM, Bruin JP, Den Boer JW, Walker JT, Crespi S. Growth of Legionella anisa in a model drinking water system to evaluate different shower outlets and the impact of cast iron rust. Int J Hyg Environ Health 2017; 220 (08) 1295-1308
- 71 Vittal R, Raj JRM, Kumar BK, Karunasagar I. Iron content as an indicator for Legionella species in artificial water systems. Med Leg Update 2021; 21 (01) 803-808
- 72 van der Kooij D, Veenendaal HR, Scheffer WJ. Biofilm formation and multiplication of Legionella in a model warm water system with pipes of copper, stainless steel and cross-linked polyethylene. Water Res 2005; 39 (13) 2789-2798
- 73 Zacheus OM, Martikainen PJ. Occurrence of legionellae in hot water distribution systems of Finnish apartment buildings. Can J Microbiol 1994; 40 (12) 993-999
