CC BY-NC-ND 4.0 · J Lab Physicians 2021; 13(02): 112-117
DOI: 10.1055/s-0041-1726669
Original Article

Performance of 3 mL versus 5 mL Discarded Volume for Blood Sampling from Central Venous Access Device

1   Department of Medical Surgical Nursing, College of Nursing, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India
,
MJ Kumari
2   College of Nursing, JIPMER, Puducherry, India
,
R Venkateswaran
3   Department of Medicine, JIPMER, Puducherry, India
,
PR Lakshmi
4   Department of Pharmacy, JIPMER, Puducherry, India
,
Lakshmi Ramamoorthy
2   College of Nursing, JIPMER, Puducherry, India
› Author Affiliations
Funding Sources Intramural fund received from JIPMER.

Abstract

Background Central venous access devices (CVAD) are an essential part of safe practices in critical care, which enable effective venous access and help in avoiding repeated venipuncture. Discard method is widely practiced for blood sampling. A single occasion of blood sampling may cause minimal blood loss; however, the cumulative volume sequential sampling may become clinically significant. The study aims to reduce diagnostic blood loss, ensuring that the subsequent blood sample is not diluted or contaminated by residual intraluminal fluid.

Patients and Methods Within-subjects comparative design was adopted for 64 adult patients in the medical intensive care unit of a tertiary hospital. Two blood samples, using 3 mL and 5 mL discarded volume methods, were collected from each patient. Six serum parameters were measured on each of the paired samples and compared.

Statistical Analysis Used Paired t-test and Wilcoxon signed rank test were used for comparing the two methods. Bland–Altman plot analysis and intraclass correlation were used for clinically meaningful analysis.

Results When tested for fixed bias, there is no statistically significant difference between the methods. Potassium and creatinine levels showed significant proportional bias. The agreement limits of sodium, potassium, creatinine, and direct bilirubin were outside the clinically accepted interval, but the proportion of samples outside these intervals was less than 10%. All serum parameters showed excellent reliability, except for sodium which demonstrated good reliability.

Conclusions The practice of discarding 3 mL of blood for discard method is suggested, instead of the standard 5 mL to reduce iatrogenic blood loss. Thus, nurses in critical care are uniquely positioned to limit the diagnostic blood loss while obtaining blood samples.



Publication History

Article published online:
17 June 2021

© 2021. The Indian Association of Laboratory Physicians. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Cole M, Price L, Parry A. et al. A study to determine the minimum volume of blood necessary to be discarded from a central venous catheter before a valid sample is obtained in children with cancer. Pediatr Blood Cancer 2007; 48 (07) 687-695
  • 2 Berreth M. Blood Sampling from Central Vascular Access Devices. Infusion Nurses Society: India Eight National Conference on Setting the Standard for Infusion Care. Available at: http://www.insindia.org/images/i-news/INS-Newsletter-2019.pdf. Accessed October 5, 2020
  • 3 Infusion Nursing Society. Infusion therapy: standard of practice in blood sampling from CVAD. J Infus Nurs 2016; 39 (01) S87-S91
  • 4 Dech ZF, Szaflarski NL. Nursing strategies to minimize blood loss associated with phlebotomy. AACN Clin Issues 1996; 7 (02) 277-287
  • 5 Coene KLM, Roos AN, Scharnhorst V. Iatrogenic anemia/twenty-five million liters of blood into the sewer: comment. J Thromb Haemost 2015; 13 (06) 1160-1161
  • 6 Wyant S, Crickman R. Determining the minimum discard volume for central venous catheter blood draws. Clin J Oncol Nurs 2012; 16 (05) 454-458
  • 7 Mayo DJ, Dimond EP, Kramer W. Horne MK III. Discard volumes necessary for clinically useful coagulation studies from heparinized Hickman catheters. Oncol Nurs Forum 1996; 23 (04) 671-675
  • 8 Winokur EJ, Pai D, Rutledge DN. et al. Blood culture accuracy: discards from central venous catheters in pediatric oncology patients in the emergency department. J Emerg Nurs 2014; 40 (04) 323-329
  • 9 Barton SJ, Chase T, Latham B, Rayens MK. Comparing two methods to obtain blood specimens from pediatric central venous catheters. J Pediatr Oncol Nurs 2004; 21 (06) 320-326
  • 10 Lu MJ, Zhong WH, Liu YX, Miao HZ, Li YC, Ji MH. Sample size for assessing agreement between two methods of measurement by Bland-Altman method. Int J Biostat 2016; 12 (02) 12
  • 11 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1 (84/76) 307-310
  • 12 Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995; 346 (89/82) 1085-1087
  • 13 Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8 (02) 135-160
  • 14 Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 2016; 15 (02) 155-163
  • 15 Portney LG, Watkins MP. Foundations of Clinical Research: Applications to Practice. New Jersey: Prentice Hall 2000
  • 16 Ortells-Abuye N, Busquets-Puigdevall T, Díaz-Bergara M, Paguina-Marcos M, Sánchez-Pérez I. A cross-sectional study to compare two blood collection methods: direct venous puncture and peripheral venous catheter. BMJ Open 2014; 4 (02) e004250
  • 17 Mackenzie CJ, McGowan CM, Pinchbeck G, Carslake HB. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: jugular venipuncture and indwelling intravenous catheter. Equine Vet J 2017; 0: 1-6
  • 18 Byrne D. Comparing the push-pull versus discard blood sample method from adult central vascular access devices. J Infus Nurs 2016; 39 (03) 130-135
  • 19 Adlard K. Examining the push-pull method of blood sampling from central venous access devices. J Pediatr Oncol Nurs 2008; 25 (04) 200-207
  • 20 Shulman RJ, Phillips S, Laine L. et al. Volume of blood required to obtain central venous catheter blood cultures in infants and children. JPEN J Parenter Enteral Nutr 1993; 17 (02) 177-179