CC BY-NC-ND 4.0 · Annals of Otology and Neurotology 2020; 3(01): 01-09
DOI: 10.1055/s-0040-1715552
Original Article

Role of High-Resolution CT and MRI in Predicting the Degree of Difficulty in Patients undergoing Cochlear Implant Surgery: An Institutional Experience

Preeti Tiwari
1   Department of Radio Diagnosis, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
,
Sheo Kumar
1   Department of Radio Diagnosis, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
,
Prabhaker Mishra
2   Biostatistics and Health Informatics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
,
Rajat Jain
3   Division of Neuro-otology, Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
,
Namita Mohindra
1   Department of Radio Diagnosis, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
,
Archana Gupta
1   Department of Radio Diagnosis, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
,
Amit Keshri
3   Division of Neuro-otology, Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
› Institutsangaben

Abstract

Introduction Preoperative imaging is a standard practice for cochlear implant candidacy. We are discussing association between surgical feasibility and various anatomical details of middle and inner ear by both high-resolution computed tomography (HRCT) and 3T magnetic resonance imaging (MRI) in patients with bilateral sensorineural hearing loss (SNHL) and are used as a guide during surgery as well as foresee complications in cochlear implantation.

Materials and Methods A total of 56 patients of aged 1 to 5 years (prelingual) and > 1 years (postlingual or perilingual) having bilateral SNHL were included in the study. HRCT temporal bone and MRI head was done in all candidates. Based on the imaging findings of CT and MRI, patients were divided into two categories (normal and abnormal). Demographic and clinical values were compared between two groups. Binary logistic regression analysis was used to identify the predictors of the outcome variable (surgical difficulty).

Results Out of 56 patients, 55 underwent cochlear implantation by Veria technique, one patient having Michel’s deformity was denied surgery and was advised brain stem implant. Note that 69.1% patients had no radiological abnormality, while 30.9% patients showed abnormality including acquired disease and malformation. Out of the total study patients, 18% (n = 10) showed various type of congenital inner ear malformation. Large size of the external auditory canal (EAC), high basal turn angle (BTA), and increased distance between tympanic segment of facial canal to EAC (midpoint between level of I-S joint corresponding to EAC and exit of chordae tympanic at level of EAC), all these factors showed inverse relationship with difficulty in surgery, which were found to be statistically significant.

Conclusion The imaging in cochlear implant patients is an essential tool for preoperative assessment of candidacy, surgical planning, and avoid intra- and postoperative complications. BTA and distance between tympanic segment of facial nerve and EAC (midpoint between level of I-S joint corresponding to EAC and exit of chordae tympanic at level of EAC) are important predictors for evaluating intra- and postoperative complications.



Publikationsverlauf

Artikel online veröffentlicht:
26. August 2020

© .

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Maniglia AJ. State of the art on the development of the implantable hearing device for partial hearing loss. Otolaryngol Clin North Am 1996; 29 (02) 225-243
  • 2 Sorkin DL. Sorkin Cochlear implantation in the world’s largest medical device market: Utilization and awareness of cochlear implants in the United States. Cochlear Implants Int 2013; 14 (Suppl. 01) S4-S12 Doi: 10.1179/1467010013Z.00000000076
  • 3 Zaghloul RA, Sheikh ML, Baky FA, Nouem KI. Role of high resolution CT and radiography in postoperative evaluation of cochlear implantation. Egypt J Radiol Nucl Med 2011; 42 (02) 177-184
  • 4 Witte RJ, Lane JI, Driscoll CLW. et al. Pediatric and adult cochlear implantation. Radiographics 2003; 23 (05) 1185-1200
  • 5 Lima Júnior LR, Rocha MD, Walsh PV, Antunes CA, Dias Ferreira Calhau CM. Evaluation by imaging methods of cochlear implant candidates: radiological and surgical correlation. Rev Bras Otorrinolaringol (Engl Ed) 2008; 74 (03) 395-400
  • 6 Vlastarakos PV, Nikolopoulos TP, Pappas S, Buchanan MA, Bewick J, Kandiloros D. Cochlear implantation update: contemporary preoperative imaging and future prospects - the dual modality approach as a standard of care. Expert Rev Med Devices 2010; 7 (04) 555-567
  • 7 Hang AX, Kim GG, Zdanski CJ. Cochlear implantation in unique pediatric populations. Curr Opin Otolaryngol Head Neck Surg 2012; 20 (06) 507-517
  • 8 Chaturvedi A, Mohan C, Mahajan SB, Kakkar V. Imaging of cochlear implants. Indian J Radiol Imaging 2006; 16: 385-392
  • 9 Lin YL, Wu CM, Toh CH. et al. Magnetic resonance imaging evaluation for predictive factors of cochlear nerve deficiency in pediatric cochlear implant candidates. Radio Sci 2013; 38: 43-50
  • 10 Agarwal SK, Singh S, Ghuman SS, Sharma S, Lahiri AK. Radiological assessment of the Indian children with congenital sensorineural hearing loss. Int J Otolaryngol 2014; 2014: 808759
  • 11 Wu WJ, He XB, Tan LH. et al. Imaging assessment of profound sensorineural deafness with inner ear anatomical abnormalities. J Otol 2015; 10 (01) 29-38
  • 12 Joshi VM, Navlekar SK, Kishore GR, Reddy K, Kumar ECV. CT and MR imaging of the inner ear and brain in children with congenital sensorineural hearing loss. Radiographics 2012; 32: 683-698
  • 13 Tamplen M, Schwalje A, Lustig L, Alemi AS, Miller ME. Utility of preoperative computed tomography and magnetic resonance imaging in adult and pediatric cochlear implant candidates. Laryngoscope 2016; 126 (06) 1440-1445
  • 14 Young JY, Ryan ME, Young NM. Preoperative imaging of sensorineural hearing loss in paediatric candidates for cochlear implantation. Radiographics 2014; 34: E133-E149
  • 15 Vaid S, Vaid N. Imaging for cochlear implantation: structuring a clinically relevant report. Clin Radiol 2014; 69 (07) e9-e24