J Hand Microsurg 2022; 14(02): 153-159
DOI: 10.1055/s-0040-1714434
Original Article

Sterility of Miniature C-arm Fluoroscopy in Hand and Upper Extremity Surgery

James P. Hovis*
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Stephanie N. Moore-Lotridge*
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Ashton Mansour
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Breanne H.Y. Gibson
2   Department of Pharmacology, Vanderbilt University, Robinson Research, Nashville, Tennessee, United States
,
Douglas R. Weikert
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Mihir J. Desai
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Sandra S. Gebhart
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Jonathan G. Schoenecker
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
2   Department of Pharmacology, Vanderbilt University, Robinson Research, Nashville, Tennessee, United States
3   Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee, United States
4   Department of Pediatrics, Vanderbilt University Medical Center, Nashville, Tennessee, United States
,
Donald H. Lee
1   Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, United States
› Author Affiliations
Funding S.N.M.L. was supported during her graduate work by a NIH-sponsored predoctoral training grant (T32GM007628); otherwise, no funding was received specifically for this project.

Abstract

Previous studies have demonstrated that sterile equipment is frequently contaminated intraoperatively, yet the incidence of miniature c-arm (MCA) contamination in hand and upper extremity surgery is unclear. To examine this incidence, a prospective study of MCA sterility in hand and upper extremity cases was performed in a hospital main operating room (MOR) (n = 13) or an ambulatory surgery center operating room (AOR) (n = 16) at a single tertiary care center. Case length, MCA usage parameters, and sterility of the MCA through the case were examined. We found that MOR surgical times trended toward significance (p = 0.055) and that MOR MCAs had significantly more contamination prior to draping than AOR MCAs (p < 0.001). In MORs and AORs, 46.2 and 37.5% of MCAs respectively were contaminated intraoperatively. In MORs and AORs, 85.7 and 80% of noncontaminated cases, respectively, used the above hand- table technique, while 50 and 83.3% of contaminated MOR and AOR cases, respectively, used a below hand-table technique. Similar CPT codes were noted in both settings. Thus, a high-rate of MCA intraoperative contamination occurs in both settings. MCA placement below the hand-table may impact intraoperative contamination, even to distant MCA areas. Regular sterilization of equipment and awareness of these possible risk factors could lower bacterial burden.

* Both the authors contributed equally to the study.


Supplementary Material



Publication History

Article published online:
26 July 2020

© 2020. Society of Indian Hand Surgery & Microsurgeons. All rights reserved.

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Bible JE, O’Neill KR, Crosby CG, Schoenecker JG, McGirt MJ, Devin CJ. Microscope sterility during spine surgery. Spine 2012; 37 (07) 623-627
  • 2 Platt AJ, Page RE. Post-operative infection following hand surgery. Guidelines for antibiotic use. J Hand Surg [Br] 1995; 20 (05) 685-690
  • 3 Alizo G, Onayemi A, Sciarretta JD, Davis JM. Operating room foot traffic: a risk factor for surgical site infections. Surg Infect (Larchmt) 2019; 20 (02) 146-150
  • 4 DiBartola AC, Barron C, Smith S. et al Decreasing room traffic in orthopedic surgery: a quality improvement initiative. Am J Med Qual 2019; 34 (06) 561-568
  • 5 Alamanda VK, Springer BD. The prevention of infection: 12 modifiable risk factors. Bone Joint J 2019; 101-B (1_Supple_A) 3-9
  • 6 Held M, Mignemi M, O’Rear L. et al Stuffed animals in the operating room: a reservoir of bacteria with a simple solution. J Pediatr Orthop 2015; 35 (08) e110-e112
  • 7 Biswas D, Bible JE, Whang PG, Simpson AK, Grauer JN. Sterility of C-arm fluoroscopy during spinal surgery. Spine 2008; 33 (17) 1913-1917
  • 8 Eberlin KR, Ring D. Infection after hand surgery. Hand Clin 2015; 31 (02) 355-360
  • 9 Claessen FM, Braun Y, van Leeuwen WF, Dyer GS, van den Bekerom MP, Ring D. What factors are associated with a surgical site infection after operative treatment of an elbow fracture?. Clin Orthop Relat Res 2016; 474 (02) 562-570
  • 10 Hosseini P, Mundis Jr GM, Eastlack R. et al Do longer surgical procedures result in greater contamination of surgeons’ hands?. Clin Orthop Relat Res 2016; 474 (07) 1707-1713
  • 11 Gershkovich GE, Tiedeken NC, Hampton D, Budacki R, Samuel SP, Saing M. A comparison of three C-Arm draping techniques to minimize contamination of the surgical field. J Orthop Trauma 2016; 30 (10) e351-e356
  • 12 Peters PG, Laughlin RT, Markert RJ, Nelles DB, Randall KL, Prayson MJ. Timing of C-arm drape contamination. Surg Infect (Larchmt) 2012; 13 (02) 110-113
  • 13 Andersson BM, Lidgren L, Schalén C, Steen A. Contamination of irrigation solutions in an operating theatre. Infect Control 1984; 5 (07) 339-341
  • 14 Baird RA, Nickel FR, Thrupp LD, Rucker S, Hawkins B. Splash basin contamination in orthopaedic surgery. Clin Orthop Relat Res 1984; (187) 129-133
  • 15 Hussein JR, Villar RN, Gray AJ, Farrington M. Use of light handles in the laminar flow operating theatre–is it a cause of bacterial concern?. Ann R Coll Surg Engl 2001; 83 (05) 353-354
  • 16 Robinson AH, Drew S, Anderson J, Bentley G, Ridgway GL. Suction tip contamination in the ultraclean-air operating theatre. Ann R Coll Surg Engl 1993; 75 (04) 254-256
  • 17 Sankar B, Ray P, Rai J. Suction drain tip culture in orthopaedic surgery: a prospective study of 214 clean operations. Int Orthop 2004; 28 (05) 311-314
  • 18 Menendez ME, Lu N, Unizony S, Choi HK, Ring D. Surgical site infection in hand surgery. Int Orthop 2015; 39 (11) 2191-2198
  • 19 Lipira AB, Sood RF, Tatman PD, Davis JI, Morrison SD, Ko JH. Complications within 30 days of hand surgery: an analysis of 10,646 patients. J Hand Surg Am 2015; 40 (09) 1852-1859