CC BY-NC-ND 4.0 · Indian Journal of Neurosurgery 2020; 9(03): 230-232
DOI: 10.1055/s-0040-1713699
Techniques in Neurosurgery

Technical Nuances of Ventriculoatrial Shunt Using Seldinger Technique for Percutaneous Insertion of Distal Shunt Catheter

Yerragunta Thirumal
1   Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
,
Vamsi Krishna Yerramneni
1   Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
,
Ram Nadha Reddy Kanala
1   Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
,
Vishwa Kumar Karanth
1   Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
,
Swapnil Kolpakwar
1   Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
,
Vikram Manure Namdev
1   Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
,
Rajesh Babu VV
2   Department of Anesthesia, Nizam’s Institute of Medical Sciences, Hyderabad, Telangana, India
› Author Affiliations

Abstract

Introduction One of the most seen neurosurgical complications is the ventriculoperitoneal (VP) shunt failure. The cause can be often due to peritoneal malabsorption of cerebrospinal fluid. The next safer alternative is to place a ventriculoatrial (VA) shunt. Various methods of access to the right atrium had been described. The percutaneous method of insertion of distal catheter using Seldinger technique is a safer alternative to open method. We describe the percutaneous insertion of distal catheter using Seldinger technique, modifications in the method, and specific tools required for the insertion.

Clinical History The patient is a 22-year-old male who is a known case of tubercular meningitis with recurrent failure of VP shunt due to malabsorption at peritoneal end of catheter. During the last hospital visit, he presented with altered sensorium and computed tomography scan brain showed ventriculomegaly. He was planned for VA shunt placement.

Surgical Technique The insertion of ventricular end of the catheter is similar to any other shunt placement. The internal jugular vein (IJV) was punctured using introducer needle and guide wire was placed in the IJV at the level of T6-T7 and the serial dilators passed on the guide wire for creating a track for passage of shunt catheter. The shunt catheter was passed over the guide wire to the desired vertebral level and distal shunt catheter is connected proximally to the shunt catheter in the neck.

Conclusion The percutaneous insertion of distal catheter with serial dilators using Seldinger technique is a safe and effective method for VA shunt placement.



Publication History

Article published online:
25 September 2020

© 2020. Neurological Surgeons’ Society of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Guice KS, Kosloske AM, Turner P, Wachtel T. Recurrent pseudocyst from a ventriculoperitoneal shunt. An unusual abdominal mass. Am J Dis Child 1978; 132 (03) 285-286
  • 2 Takase H, Tatezuki J, Ikegaya N. et al. Critical ventriculo-peritoneal shunt failure due to peritoneal tuberculosis: case report and diagnostic suggestions for abdominal pseudocyst. Surg Neurol Int 2014; 5 (Supplement) 71 DOI: 10.4103/2152-7806.132583.
  • 3 Ventriculoatrial Shunting - MedOne. Thieme. Available at: https://medone.thieme.com/ebooks/1273913?fromSearch=true#/ebook_1273913_SL54677488. Accessed March 1, 2020
  • 4 Konar SK, Maiti TK, Bir SC, Kalakoti P, Nanda A, Robert H. Robert H. Pudenz (1911-1998) and ventriculoatrial shunt: historical perspective. World Neurosurg 2015; 84 (05) 1437-1440
  • 5 Pudenz RH. Experimental and clinical observations on the shunting of cerebrospinal fluid into the circulatory system. Clin Neurosurg 1957-1958 5: 98-114
  • 6 Pudenz RH, Russell FE, Hurd AH, Shelden CH. Ventriculo-auriculostomy; a technique for shunting cerebrospinal fluid into the right auricle; preliminary report. J Neurosurg 1957; 14 (02) 171-179
  • 7 Evangelos D, Dimitrios G, Georgios S, Nikolaos E, Filippos P, Marios T. Percutaneous placement of the peripheral catheter to the subclavian vein for a VA shunt. Pan Afr Med J 2017; DOI: 10.11604/pamj.2017.27.42.11374.
  • 8 Sorge O, Vitzthum HE, Schaffranietz L, Günther L, Trantakis C. [A new set for percutaneous implantation of the cardiac catheter in ventriculo-atrial shunt systems. A new technical note]. Zentralbl Neurochir 1994; 55 (02) 125-127
  • 9 Słowiński J, Stomal M, Skaba T, Pieniazek J, Mrówka R. [Percutaneous ventriculoatrial shunt: experience with 179 cases]. Neurol Neurochir Pol. 40(3):198–202
  • 10 Harrison MJ, Welling BG, DuBois JJ. A new method for inserting the atrial end of a ventriculoatrial shunt. Technical note. J Neurosurg 1996; 84 (04) 705-707