CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2020; 55(06): 708-714
DOI: 10.1055/s-0040-1702951
Artigo Original
Quadril

Dual mobility cup in total hip arthroplasty. The experiense of the university hospital

Artikel in mehreren Sprachen: português | English
1   Grupo de cirurgia do quadril e joelho, Serviço de Ortopedia e Traumatologia, Hospital Universitário, Universidade Federal do Maranhão, São Luís, Maranhão, Brasil
› Institutsangaben

Abstract

Objective To evaluate the incidence of prosthetic instability in a consecutive series of 42 cases of total hip arthroplasty using dual mobility cup.

Methods A retrospective study of 38 patients undergoing primary or revision total hip arthroplasty (THA) using the acetabular dual-mobility cup (DMC) implant between January 2012 and January 2018. The rates of complications and instability after surgery were evaluated.

Results In total, 42 arthroplasties were performed in 38 patients, with a minimum follow-up of 16 months. The mean age of the sample was 60 years. In 38 cases, we used a cementless DMC, and, in the other 4 cases, a cemented DMC. There were no cases of early or late instability.

Conclusion The series herein presented proves the good result of the DMC in cases of primary arthroplasty, complex and complicated cases of failed osteosynthesis of proximal femoral fractures, and revision for THA instability. The absence of episodes of prosthetic instability and complications in complex cases of primary and revision THA increases the confidence in this concept.



Publikationsverlauf

Eingereicht: 20. August 2019

Angenommen: 12. Dezember 2019

Artikel online veröffentlicht:
08. Juni 2020

© 2020. Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Revinter Publicações Ltda.
Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, Brazil

 
  • Referências

  • 1 Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet 2007; 370 (9597): 1508-1519
  • 2 Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007; 89 (04) 780-785
  • 3 Hailer NP, Weiss RJ, Stark A, Kärrholm J. The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty Register. Acta Orthop 2012; 83 (05) 442-448
  • 4 Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ. The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 2009; 91 (01) 128-133
  • 5 Faldini C, Stefanini N, Fenga D. et al. How to prevent dislocation after revision total hip arthroplasty: a systematic review of the risk factors and a focus on treatment options. J Orthop Traumatol 2018; 19 (01) 17
  • 6 Daly PJ, Morrey BF. Operative correction of an unstable total hip arthroplasty. J Bone Joint Surg Am 1992; 74 (09) 1334-1343
  • 7 Meek RM, Allan DB, McPhillips G, Kerr L, Howie CR. Epidemiology of dislocation after total hip arthroplasty. Clin Orthop Relat Res 2006; 447 (447) 9-18
  • 8 Enocson A, Pettersson H, Ponzer S, Törnkvist H, Dalén N, Tidermark J. Quality of life after dislocation of hip arthroplasty: a prospective cohort study on 319 patients with femoral neck fractures with a one-year follow-up. Qual Life Res 2009; 18 (09) 1177-1184
  • 9 Guyen O, Chen QS, Bejui-Hugues J, Berry DJ, An KN. Unconstrained tripolar hip implants: effect on hip stability. Clin Orthop Relat Res 2007; 455 (455) 202-208
  • 10 Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty 2002; 17 (03) 282-288
  • 11 Coventry MB. Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg Am 1985; 67 (06) 832-841
  • 12 Bourne RB, Mehin R. The dislocating hip: what to do, what to do. J Arthroplasty 2004; 19 (04) (Suppl. 01) 111-114
  • 13 Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br 2005; 87 (06) 762-769
  • 14 Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am 1982; 64 (09) 1295-1306
  • 15 Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital cost of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 2006; 88 (02) 290-294
  • 16 Berry DJ, von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 2005; 87 (11) 2456-2463
  • 17 Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br 1972; 54 (01) 61-76
  • 18 McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br 1966; 48 (02) 245-259
  • 19 Chughtai M, Mistry JB, Diedrich AM. et al. Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA. Clin Orthop Relat Res 2016; 474 (10) 2181-2187
  • 20 Bouchet R, Mercier N, Saragaglia D. Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 2011; 97 (01) 2-7
  • 21 Combes A, Migaud H, Girard J, Duhamel A, Fessy MH. Low rate of dislocation of dual-mobility cups in primary total hip arthroplasty. Clin Orthop Relat Res 2013; 471 (12) 3891-3900
  • 22 Prudhon JL, Ferreira A, Verdier R. Dual mobility cup: dislocation rate and survivorship at ten years of follow-up. Int Orthop 2013; 37 (12) 2345-2350
  • 23 Tarasevicius S, Robertsson O, Dobozinskas P, Wingstrand H. A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures. Hip Int 2013; 23 (01) 22-26
  • 24 Darrith B, Courtney PM, Della Valle CJ. Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature. Bone Joint J 2018; 100-B (01) 11-19
  • 25 De Martino I, Triantafyllopoulos GK, Sculco PK, Sculco TP. Dual mobility cups in total hip arthroplasty. World J Orthop 2014; 5 (03) 180-187
  • 26 Lu-Yao GL, Keller RB, Littenberg B, Wennberg JE. Outcomes after displaced fractures of the femoral neck. A meta-analysis of one hundred and six published reports. J Bone Joint Surg Am 1994; 76 (01) 15-25
  • 27 Adam P, Philippe R, Ehlinger M. et al. French Society of Orthopaedic Surgery and Traumatology (SoFCOT), Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 2012; 98 (03) 296-300
  • 28 Philippot R, Boyer B, Farizon F. Intraprosthetic dislocation: a specific complication of the dual-mobility system. Clin Orthop Relat Res 2013; 471 (03) 965-970
  • 29 Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C. The dual mobility socket concept: experience with 668 cases. Int Orthop 2011; 35 (02) 225-230