CC BY-NC-ND 4.0 · Eur J Dent 2013; 07(01): 127-132
DOI: 10.1055/s-0039-1699007
Original Article
Dental Investigation Society

Ultrasonic cavity preparation using CVD coated diamond bur: A case report

Beatriz Tholt de Vasconcellos
1   Department of Dentistry, Universidade Veiga de Almeida
,
Jeffrey Y Thompson
2   Department of Prosthodontics, College of Dental Medicine, Nova Southeastern University
,
Manoel Roberto de Paula Macedo
3   Oregon Health and Sciences University
,
Janaína Monalisa de Oliveira Oliveira Maia
1   Department of Dentistry, Universidade Veiga de Almeida
,
Margareth Oda
4   Department of Operative Dentistry, School of Dentistry, University of São Paulo
,
Narciso Garone Netto
4   Department of Operative Dentistry, School of Dentistry, University of São Paulo
› Author Affiliations
Further Information

Publication History

Publication Date:
30 September 2019 (online)

ABSTRACT

Before any restorative procedure can be undertaken a proper cavity preparation is required. This clinical step is the mechanical alteration of the tooth to receive a restorative material with which a satisfactory form, function and the esthetics of the tooth will be established. In recent years improvements in materials and techniques have been devised and new technologies are now available for this purpose. The aim of the present study is to report two clinical cases in which a CVD coated diamond bur coupled to an ultrasonic handpiece is used in dental preparation. This technique provides an accurate and conservative tooth preparation with ideal access and visibility and because of enhanced efficiency can also play a role in eliminating some of the patient discomfort of the dental treatment. (Eur J Dent 2013;7:127-132)

 
  • References

  • 1 Sturdevant C, Roberson T, Heymann H, Swift Jr E. The art and science of Operative Dentistry. 3rd ed. St. Louis: CV Mosby; 1995.
  • 2 Borges C, Magne P, Pfender E, Heberlein J. Dental diamond burs made with a new technology. J Prost Dent 1999;82:73-79.
  • 3 Celiberti P, Francescut P, Lussi A. Performance of four dentine excavation methods in deciduous teeth. Caries Res 2006;40:117-123.
  • 4 Macedo MRP. Características da superfície dentinária e do esfregaço formado por instrumentos abrasivos diamantados: rotatório convencional, CVD rotatório e CVD por ultrasom. Estudo in vitro. São Paulo: Universidade de São Paulo; 2005.
  • 5 Trava-Airoldi V, Corat E, Pena A, Leite N, Baranauskas V, Salvadori M. Columnar CVD diamond growth structure on irregular surface substrates. Diamond Relat Mater 1995;4:1255-1259.
  • 6 Conde A. Estudo comparativo entre preparo cavitário ultrasônico e alta rotação. RGO 2004;52:169-172.
  • 7 Conrado L, Trava-Airoldi V, Corat E. The use of a CVD - Coated Diamond Bur Coupled to an Ultrasound Handpiece in Dental Preparation. [acesso em: 2012-02-07]. Disponível em: URL: http://www.cvd-diamante.com.br/ref-bibliográficas.htm.2003.
  • 8 Ritter A. Posterior resin-based composite restorations: clinical recommendations for optimal success. J Esthet Restor Dent 2001;13:88-99.
  • 9 Lopes G, Vieira L, Araújo E. Direct Composite Resin Restorations: A review of some clinical procedures to achieve predictable results in posterior teeth. J Esthet Restor Dent 2004;16:19-32.
  • 10 Peutzfeldt A, Asmussen E. Oxygen-inhibited surface layers on microfill pontic. Acta Odontol Scand 1989;47:31-33.
  • 11 Rueggeberg F, Margeson D. The Effect of Oxygen Inhibition On An Unfilled/Filled Composite System. J Dental Res 1990;69:1652-1658.
  • 12 Oliveira MAVC, Biffi JCG, Dechichi P. CVD (Chemical Vapor Deposition) - solution for control of temperature during cavity preparation? Rev Odontol UNESP 2009;38:363-369.
  • 13 Lima L, Motisuki C, Santos-Pinto, Corat E. Cutting characteristics of dental diamond burs made with CVD technology. Braz Oral Res 2006;20:155-161.
  • 14 Vanderlei A, Borges A, Cavalcanti B, Rode S. Ultrasonic versus high-speed cavity preparation: Analyses of increases in pulpal temperature and time to complete preparation. J Prosthet Dent 2008;100:107-109.
  • 15 Mollica FB, Camargo FP, Zamboni SC, Pereira S, Teixeira S, Nogueira-Junior L. Pulpal temperature increase with highspeed handpiece, Er: YAG laser and ultrasound tips. J Appl Oral Sci 2008;16:209-213.
  • 16 Predebon JC, Flório FM, Basting RT. Use of CVDentUS diamond tips for ultrasound in cavity preparation. J Contemp Dent Pract 2006;7:50-58.
  • 17 Macedo MRP, Vasconcellos BT, Pereira Neto JP, Pereira M, Garone-Netto N. Pontas CVD e Ultra-Som como nova técnica cirúrgica. Aplicação no levantamento de seio maxilar. Clínica-International J Braz Dent 2006;2:44-47.
  • 18 Clorovale Diamantes: CVDentus® (online). [acesso em: 2012-02-07]. Disponível em: URL: http://www.cvdentus.com.br.