Thromb Haemost 1995; 74(06): 1465-1467
DOI: 10.1055/s-0038-1649966
Original Articles
Coagulation
Schattauer GmbH Stuttgart

Multi-Center Calibration of the Third BCR Reference Material for Thromboplastin, Rabbit, Plain, Coded CRM 149S

Long-term Stability of Previous BCR Reference Materials
A M H P van den Besselaar
The Haemostasis and Thrombosis Research Center, Department of Haematology, Leiden University Hospital, Leiden, The Netherlands
› Author Affiliations
Further Information

Publication History

Received 05 May 1995

Accepted after resubmission 25 August 1995

Publication Date:
10 July 2018 (online)

Summary

In a collaborative study by eleven laboratories performed within the framework of the European Community Bureau of Reference (BCR), a third reference material for thromboplastin, rabbit, plain, has been calibrated against RBT/90, the current WHO international reference preparation for thromboplastin, rabbit, plain. This third reference material (coded CRM 149S) has a mean International Sensitivity Index (ISI)of 1.257 with a standard error of the mean of 0.013.

The previous BCR reference material for thromboplastin, rabbit, plain (coded CRM 149R) and the reference material for thromboplastin, bovine, combined (coded OBT/79) were also included in the trial for assessment of the long-term stability of the ISI values. The relationship between ISI values determined in the present study was nearly identical to that of the historical values. These results offer reassurance with regard to the long-term stability of these reference materials.

 
  • References

  • 1 WHO Expert Committee on Biological Standardization. Thirty-fourth Report. WHO Tech Rep Scr 1984; 18-19
  • 2 van den Besselaar AM H P. Multi-center study of replacement of the international reference preparation for thromboplastin, rabbit, plain. Thromb Haemost 1993; 70: 794-799
  • 3 Hermans J, Van den Besselaar AM P H, Loeliger EA, Van der Velde EA. A collaborative calibration study of reference materials for thromboplastins. Thromb Haemost 1983; 50: 712-717
  • 4 Van den Besselaar AM P H, Bertina RM. Multi-center calibration of the second reference material for thromboplastin, rabbit, plain, coded CRM 149R. Thromb Haemost 1991; 65: 263-267
  • 5 Van den Besselaar AM P H. The certification of the third reference material for rabbit thromboplastin CRM 149S. BCR information European Commission; Brussels: 1994
  • 6 Van den Besselaar AM P H, Wittcveen E, Schacfer-van Mansfeld H, Meeuwisse-Braun J, Strebus A. Accelerated degradation test of lyophilized recombinant tissue factor-liposome preparations. Thromb Haemost 1995; 73: 392-397
  • 7 WHO Expert Committee on Biological Standardization. Thirty-third Report. WHO Techn Rep Ser 1983; 81-105
  • 8 Van den Besselaar AM P H, Bertina RM. Multi-center study of thromboplastin calibration precision. Influence of reagent species, composition and international sensitivity index (ISI) Thromb Haemost 1993; 69: 35-40
  • 9 Denson KW E. Thromboplastin-sensitivity, precision and other characteristics. Clin Lab Haemat 1988; 10: 315-328
  • 10 Van den Besselaar AM P H, Bertina RM. Considerations on the true value of the international normalized ratio in the control of oral anticoagulant therapy. Br J Haematol 1994; 88: 223-227
  • 11 Tripodi A, Poller L, Van den Besselaar AM P H, Mannucci PM. A proposed scheme for calibration of international reference preparations of thromboplastin for the prothrombin time. A report of the subcommittee for control of anticoagulation Thromb Haemost 1995; 74: 1368-1369