Vet Comp Orthop Traumatol 2000; 13(04): 185-190
DOI: 10.1055/s-0038-1632658
Original Research
Schattauer GmbH

Effect of intramedullary pin size on reducing bone plate strain

D. Hulse
1   Department of Small Animal Medicine and Surgery, College Station, Texas, USA
,
K. Ferry
2   The Bioengineering Program, Texas A & M University, College Station, Texas, USA
,
A. Fawcett
2   The Bioengineering Program, Texas A & M University, College Station, Texas, USA
,
D. Gentry
1   Department of Small Animal Medicine and Surgery, College Station, Texas, USA
,
W. Hyman
2   The Bioengineering Program, Texas A & M University, College Station, Texas, USA
,
S. Geller
1   Department of Small Animal Medicine and Surgery, College Station, Texas, USA
,
M. Slater
1   Department of Small Animal Medicine and Surgery, College Station, Texas, USA
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Received 18. November 1999

Accepted 08. Mai 2000

Publikationsdatum:
09. Februar 2018 (online)

The degrees of plate strain, coupled with various diameters of intramedullary pins, is reported. In addition, the fatigue life and stiffness of the plate/pin construct was determined.

 
  • REFERENCES

  • 1 Baumgartel F, Perren SM, Rahn BA. Animal Experimental Studies of “biological “ plate oateosynthesis of multifragment fractures of the femur. Unfallchirurg 1994; 97: 19-27.
  • 2 Brinker WO, Hohn RB, Prier WD. Manual of Internal Fixation in Small Animals. (ed 1. Berlin, Germany: Springer Verlag; 1984: 29-32.
  • 3 Dueland RT, Vanderby R, McCabe RP. Fatigue study of six and eight mm diameterinterlocking nails with screw holes of variable size and number. Vet Comp Orthop Traumatol 1997; 10: 194-9.
  • 4 Hulse DA, Hyman W, Nori M, Slater M. Reduction in Plate Strain by Addition of an Intramedullary Pin. Vet Surg 1997; 26: 451-459.
  • 5 Hulse DA, Slater M, Johnson AI. et al. unpublished data..
  • 6 Neidlinger-Wilke C, Holbein O, Grood E. et al. Effects of cyclicstrain on proliferation, metabolic activity, and alignment of human osteoblasts and fibroblasts. Trans ORS 1994; (abstr) 19: 101.
  • 7 Perren SM. Concept of biological plating using the Limited Contact Dynamic Compression Plate. Injury AO/ASIF Scientific Supplement 1991; (Suppl. 01) 22: 19-20.
  • 8 Perren SM, Cordey J. The concept of inter- fragmentary strain. In: Uhthoff HK. (ed). Current Concepts of Internal Fixation of Fractures. Berlin, Germany: Springer Verlag; 1980: 63-67.
  • 9 Rhinlander FW. The normal circulation of diaphyseal cortex and its response to fracture. J. Bone and Joint Surg 1968; 50-A: 784-800.