Summary

This study reports the application of the AO/ASIF maxillofacial mini-plate system, Compact 1.0a (MF mini-plate 1.0), in the repair of fractures in 12 cats and two small sized dogs. The malleability of these titanium mini-plates allows them to be precisely contoured and positioned to fit onto the most advantages sites of the bone. Selftapping mini-screws provide an easy application and a time-saving osteosynthesis. Fractures of miniature bones too small for the regular AO/ASIF miniimplants can be repaired successfully with this MF mini-plate 1.0 implant set. The special indications reported were the repair of fractures of the angle of the mandible in cats, articular digital fractures in small dogs and the stabilization of small avulsion fractures in cats and dogs.

This study shows the successful application of the titanium maxillofacial mini-plate, Compact 1.0, in 12 cats and two toy breed dogs. Miniature fractures, such as mandible or digit fractures, too small for the AO/ASIF mini-plate system are indications for these implants. The self-tapping screws of the maxillofacial system, Compact 1.0, with a core diameter of 0.7 mm, can be used as plate screws or interfragmentarily.

 
  • REFERENCES

  • 1 Boudrieau R, Kudisch M. Miniplate fixation for repair of mandibular and maxillary fractures in 15 dogs and 3 cats. Vet Surg 1996; 25: 277-91.
  • 2 Campy M, Lodde JP, Jaeger JH, Muster D. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J max-fac Surg 1978; 14-21.
  • 3 Ellis III E, Walker LR. Treatment of mandibular fractures using one noncompressing miniplate. J Oral Maxillofac Surg 1996; 54: 864-71.
  • 4 Ewers R, Schilli W. Metallplattenosteosynthese und Drahtosteosynthese zur Versorgung der periorbitalen Frakturen im experimentellen Versuch. Dtsch zahnarztl Z 1977; 32: 820-23.
  • 5 Montavon PM, Pohler OE, Olmstead ML, Wendenburg KL. The mini instrument set and its clinical application. Vet Comp Orthop Traumatol 1988; 45: 50-57.
  • 6 Piermattei DL. (ED.): An Atlas of Surgical Approaches to the Bones and the Joints of the Dog and the Cat. (3rd ed.).. Philadelphia: WB Saunders Company: 1993
  • 7 Piermattei DL, Flo G. In: Handbook of Small Animal Orthopedics and Fracture Repair. 3rd.ed. Piermattei DL, Flo GL. (eds). Philadelphia: WB Saunders Company; 1997
  • 8 Prein J, Rahn BA. Craniofacial Plates. In: Manual of Internal Fixation in the Craniofacial Skeleton. Prein J. (ed.). Berlin: Springer Verlag; 1998: 28-29.
  • 9 Prieur WD. Classification of screws according to function. In: Manual of Internal Fixation in Small Animals. Brinker WO, Hohn RB, Prieur WD. (eds). Berlin: Springer Verlag; 1984: 46-56.
  • 10 Sumner-Smith G. Fractures of the mandible. in: Manual of internal fixation in small animals. Brinker WO, Olmtead ML, Sumner-Smith G, Prieur WD. (eds). Springer-Verlag; Berlin: 1998: 194-99.
  • 11 Tuovinen V, Norholt SE, Sindet-Pedersen S, Jensen J. A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates. J Oral Max-fac Surg 1994; 52: 931-35.
  • 12 Verstraete FJM, Lighthelm AJ. Dental trauma by screws used in internal fixation of mandibular osteotomies in the canine. J Vet Dent 1987; 04: 4.
  • 13 Verstraete FJM, Lighthelm AJ. Dental trauma caused by screws in internal fixation of mandibular osteotomies in the dog. Vet Comp Orthop Traumatol 1992; 05: 104-8.