Repair of a gastrocolic fistula using a wire-guided, simultaneous dual scope approach

A. Nici
Department of Gastroenterology, New York Hospital, Flushing, New York, USA
,
S. Hussain
Department of Gastroenterology, New York Hospital, Flushing, New York, USA
,
M. Rubin
Department of Gastroenterology, New York Hospital, Flushing, New York, USA
,
S. Kim
Department of Gastroenterology, New York Hospital, Flushing, New York, USA
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
05. September 2013 (online)

A 72-year-old man with a history of diverticulitis 1 year previously, requiring a partial colectomy, presented to our hospital complaining of fever and weight loss over the preceding 3 weeks. Blood cultures revealed Gram-negative bacteremia. Antibiotics were initiated and a complete workup for infectious diseases was done without any success. Barium imaging and computed tomography (CT) of his abdomen revealed a 14-cm long fistulous tract extending from the greater curvature of the stomach to the area of the sigmoid colon ([Fig. 1]). It was felt that the bacteremia was most likely due to the gastrocolic fistula and endoscopic closure was planned. At upper endoscopy, the gastric fistula opening was visualized on the greater curvature of the gastric body ([Fig. 2]). After injection of contrast into the tract, a 0.025-cm Jag wire (Boston Scientific, Natick, Massachusetts, USA) was threaded into the fistula under fluoroscopic guidance ([Fig. 3]). Colonoscopy was carried out simultaneously to visualize the guide wire’s exit point, which was emerging out of a field of diverticula in the sigmoid colon. The fistula was then flushed with sterile water and a cytobrush (Cytomax II Double Lumen Cytology Brush, Wilson-Cook Medical, Winston-Salem, North Carolina, USA) was passed over the guide wire to denude the mucosa and promote closure. Lastly, both the proximal and distal ends of the fistula were closed with Resolution clips (Boston Scientific). The patient tolerated the procedure well. A repeat upper gastrointestinal series performed 4 days later failed to show the fistula and the patient was discharged. At 3 months, a lower gastrointestinal series confirmed successful long-term closure ([Fig. 4]). To our knowledge this is the first reported case of a long gastrocolic fistula being repaired via this novel method of dual endoscopic closure with use of Resolution clips.

Zoom Image
Fig. 1 Imaging findings in a 72-year-old man with a history of diverticulitis presenting with and fever and weight loss. a Barium imaging. b Computed tomography (CT) view.
Zoom Image
Zoom Image
Fig. 2 Endoscopic view showing the gastric fistula orifice on the greater curvature of the stomach.
Zoom Image
Fig. 3 A 0.025-cm Jag wire being threaded into the fistula under fluoroscopic guidance.
Zoom Image
Fig. 4 Follow-up lower gastrointestinal radiographic view showing successful long-term closure of the fistula.

Endoscopy_UCTN_Code_TTT_1AQ_2AG