Minim Invasive Neurosurg 2011; 54(03): 115-118
DOI: 10.1055/s-0031-1283170
Original Article
Georg Thieme Verlag KG Stuttgart · New York

Frameless Image-Guided Neuroendoscopy Training in Real Simulators

G. Coelho
2   Department of Neurology and Neurosurgery, Paulista School of Medicine, Federal University of São Paulo, São Paulo, SP, Brazil
,
C. Kondageski
1   Department of Neurosurgery, Neurologia Institute of Curitiba, Curitiba PR, Brazil
,
F. Vaz-Guimarães Filho
2   Department of Neurology and Neurosurgery, Paulista School of Medicine, Federal University of São Paulo, São Paulo, SP, Brazil
,
R. Ramina
1   Department of Neurosurgery, Neurologia Institute of Curitiba, Curitiba PR, Brazil
,
S. C. Hunhevicz
1   Department of Neurosurgery, Neurologia Institute of Curitiba, Curitiba PR, Brazil
,
F. Daga
1   Department of Neurosurgery, Neurologia Institute of Curitiba, Curitiba PR, Brazil
,
M. R. Lyra
3   Department of Gynecology, Federal University of Pernambuco, Recife, Pernambuco, Brazil
,
S. Cavalheiro
2   Department of Neurology and Neurosurgery, Paulista School of Medicine, Federal University of São Paulo, São Paulo, SP, Brazil
,
S. T. Zymberg
2   Department of Neurology and Neurosurgery, Paulista School of Medicine, Federal University of São Paulo, São Paulo, SP, Brazil
› Author Affiliations
Further Information

Publication History

Publication Date:
23 August 2011 (online)

Abstract

Background:

Over the last decade, neuroendoscopy has re-emerged as an interesting option in the management of intraventricular lesions in both children and adults. Nonetheless, as it has become more difficult to use cadaveric specimens in training, the development of alternative methods was vital. The aim of this study was to analyze the performance of a real simulator, in association with image-guided navigation, as a teaching tool for the training of intraventricular endoscopic procedures.

Methods:

3 real simulators were built using a special type of resin. 1 was designed to represent the abnormally enlarged ventricles, making it possible for a third ventriculostomy to be performed. The remaining 2 were designed to simulate a person’s skull and brain bearing intraventricular lesions, which were placed as follows: in the foramen of Monro region, in the frontal and occipital horns of the lateral ventricles and within the third ventricle. In all models, MRI images were obtained for navigation guidance. Within the ventricles, the relevant anatomic structures and the lesions were identified through the endoscope and compared with the position given by the navigation device. The next step consisted of manipulating the lesions, using standard endoscopic techniques.

Results:

We observed that the models were MRI compatible, easy and safe to handle. They nicely reproduced the intraventricular anatomy and brain consistence, as well as simulated intraventricular lesions. The image-based navigation was efficient in guiding the surgeon through the endoscopic procedure, allowing the selection of the best approach as well as defining the relevant surgical landmarks for each ventricular compartment. Nonetheless, as expected, navigation inaccuracies occurred. After the training sessions the surgeons felt they had gained valued experience by dealing with intraventricular lesions employing endoscopic techniques.

Conclusion:

The use of real simulators in association with image-guided navigation proved to be an effective tool in training for neuroendoscopy.

 
  • References

  • 1 Li KW, Nelson C, Suk I et al. Neuroendoscopy: past, present, and future. Neurosurg Focus 2005; 19: E1
  • 2 Kulkarni AV, Drake JM, Mallucci CL et al. Endoscopic third ventriculostomy in the treatment of childhood hydrocephalus. J Pediatr 2009; 155: 254-259
  • 3 Jenkinson MD, Hayhurst C. Al-Jumaily: The role of endoscopic third ventriculostomy in adult patients with hydrocephalus. J Neurosurg 2009; 110: 861-866
  • 4 Prat R, Galeano I. Endoscopic biopsy of foramen of Monro and third ventricle lesions guided by frameless neuronavigation: usefulness and limitations. Neurol Neurosurg. 2009 111. 579-582
  • 5 Oertel J, Krauss JK, Gaab MR. Ultrasonic aspiration in neuroendoscopy: first results with a new tool. J Neurosurg 2008; 109: 908-911
  • 6 Eppley BL, Delfino JJ. An animal model for advanced microsurgical training. J Oral Maxillofac Surg 1986; 44: 833-836
  • 7 De Paolis LT, De Mauro A, Raczkowsky J et al. Virtual model of the human brain for neurosurgical simulation. Stud Health Technol Inform 2009; 150: 811-815
  • 8 Weber D, Moser N, Rosslein R. A synthetic model for microsurgical training: a surgical contribution to reduce the number of animal experiments. Eur J Pediatr Surg 1997; 7: 204-206
  • 9 Woodman PJ, Nager CW. From the simple to the sublime: incorporating surgical models into your surgical curriculum. Obstet Gynecol Clin North Am 2006; 33: 267-281
  • 10 Zymberg S, Vaz-Guimarães Filho F, Lyra M. Neuroendoscopic training: presentation of a new real simulator. Minim Invas Neurosurg 2010; 53: 44-46
  • 11 Rhoton Jr AL. Operative techniques and instrumentation for neurosurgery. Neurosurgery 2003; 53: 907-934
  • 12 Nogueira JF, Stamm AC, Lyra M et al. Building a real endoscopic sinus and skull-base surgery simulator. Otolaryngol Head Neck Surg 2008; 139: 727-728
  • 13 Tubbs RS, Loukas M, Shoja MM et al. Feasibility of ventricular expansion postmortem: a novel laboratory model for neurosurgical training that simulates intraventricular endoscopic surgery. J Neurosurg 2009; 111: 1165-1167
  • 14 AboudK DM, Resch A, Perneczky A. Use of plastined crania in neuroendoscopy. J Int Soc Plastination 1992; 6: 15-16
  • 15 Lemole Jr GM, Banerjee PP, Luciano C et al. Virtual reality in neurosurgical education: part-task ventriculostomy simulation with dynamic visual and haptic feedback. Neurosurgery 2007; 61: 142-148
  • 16 Gallagher AG, Cates CU. Virtual reality training for the operating room and cardiac catheterisation laboratory. Lancet 2004; 364: 1538-1540
  • 17 Bakhos D, Velut S, Robier A et al. Three-dimensional modeling of the temporal bone for surgical training. Otol Neurotol 2010; 31: 328-334
  • 18 Kimura T, Morita A, Nishimura K et al. Simulation of and training for cerebral aneurysm clipping with 3-dimensional models. Neurosurgery 2009; 65: 719-725
  • 19 McDougall EM, Kolla SB, Santos RT et al. Preliminary study of virtual reality and model simulation for learning laparoscopic suturing skills. J Urol 2009; 182: 1018-1025