Abstract
Background: Minimally invasive spinal surgery (MISS) has evolved over the past years due to the combination of microsurgery, minimal access strategies and neuronavigation. Percutaneous or mini-open pedicle screw placement is a challenge, especially for surgeons not experienced in the use of biplanar fluoroscopy or stereotactic imaging techniques. The aim of the study was to compare the precision of pedicle screw fixation for lumbar fusion procedures using Iso-C/stereotactic 3D neuronavigation (3D NAV) vs. standard AP/lateral fluoroscopy (2D NAV).
Methods: Our first 42 patients undergoing MISS for one- or 2-level lumbar or lumbosacral fusion procedures for degenerative lumbar pathology were included in this study. Either 3D NAV (n=29) or standard fluoroscopy (n=13) was used to aid screw placement. Demographics, operative time, blood loss, and screw placement accuracy were evaluated. Screw placement was evaluated postoperatively using lumbar CT scanning. Accuracy of 3D NAV was evaluated by comparing intraoperative planning screenshots to postoperative CT placement of screws.
Results: There were no significant differences between groups for mean age, gender or intraoperative blood loss. 90.9% of 3D NAV screws and 73.7% of fluoroscopy screws had no pedicle perforation (p=0.04). Intraoperative navigation screenshots accurately predicted pedicle screw placement in 90.9% of cases. There was a positive correlation between 3D NAV accuracy and better screw grade (rs 0.45, p=0.036).
Conclusions: Utilization of 3D NAV for percutaneous or mini-open lumbar screw placement during the early learning curve for MISS was associated with higher screw accuracy. This study demonstrates that the use of 3D navigation can facilitate the learning curve for MISS.
Key words
image guidance - minimally invasive spine surgery - presurgical planning
References
- 1
Perez-Cruet MJ, Foley KT, Isaacs RE. et al .
Microendoscopic lumbar discectomy: technical note.
Neurosurgery.
2002;
51
S129-S136
MissingFormLabel
- 2
Hsieh PC, Koski TR, Sciubba DM. et al .
Maximizing the potential of minimally invasive spine surgery in complex spinal disorders.
Neurosurg Focus.
2008;
25
E19
MissingFormLabel
- 3
O’Toole JE, Eichholz KM, Fessler RG.
Minimally invasive far lateral microendoscopic discectomy for extraforaminal disc
herniation at the lumbosacral junction: cadaveric dissection and technical case report.
Spine J.
2007;
7
414-421
MissingFormLabel
- 4
Tredway TL, Santiago P, Hrubes MR. et al .
Minimally invasive resection of intradural-extramedullary spinal neoplasms.
Neurosurgery.
2006;
58
ONS52-ONS58
discussion ONS52–ONS58
MissingFormLabel
- 5
Kawaguchi Y, Yabuki S, Styf J. et al .
Back muscle injury after posterior lumbar spine surgery. Topographic evaluation of
intramuscular pressure and blood flow in the porcine back muscle during surgery.
Spine.
1996;
21
2683-2688
MissingFormLabel
- 6
Kawaguchi Y, Matsui H, Tsuji H.
Back muscle injury after posterior lumbar spine surgery. A histologic and enzymatic
analysis.
Spine.
1996;
21
941-944
MissingFormLabel
- 7
Weber BR, Grob D, Dvorak J. et al .
Posterior surgical approach to the lumbar spine and its effect on the multifidus muscle.
Spine.
1997;
22
1765-1772
MissingFormLabel
- 8
Sihvonen T, Herno A, Paljarvi L. et al .
Local denervation atrophy of paraspinal muscles in postoperative failed back syndrome.
Spine.
1993;
18
575-581
MissingFormLabel
- 9
Berlemann U, Monin D, Arm E. et al .
Planning and insertion of pedicle screws with computer assistance.
J Spinal Disord.
1997;
10
117-124
MissingFormLabel
- 10
Laine T, Schlenzka D, Makitalo K. et al .
Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective
clinical trial of 30 patients.
Spine.
1997;
22
1254-1258
MissingFormLabel
- 11
Schwarzenbach O, Berlemann U, Jost B. et al .
Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography
analysis.
Spine.
1997;
22
452-458
MissingFormLabel
- 12
Nolte L, Zamorano L, Arm E. et al .
Image-guided computer-assisted spine surgery: a pilot study on pedicle screw fixation.
Stereotact Funct Neurosurg.
1996;
66
108-117
MissingFormLabel
- 13
Nolte LP, Zamorano L, Visarius H. et al .
Clinical evaluation of a system for precision enhancement in spine surgery.
Clin Biomech (Bristol, Avon).
1995;
10
293-303
MissingFormLabel
- 14
Merloz P, Tonetti J, Pittet L. et al .
Pedicle screw placement using image guided techniques.
Clin Orthop Relat Res.
1998;
39-48
MissingFormLabel
- 15
Richter M, Cakir B, Schmidt R.
Cervical pedicle screws: conventional versus computer-assisted placement of cannulated
screws.
Spine.
2005;
30
2280-2287
MissingFormLabel
- 16
Richter M, Mattes T, Cakir B.
Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.
Eur Spine J.
2004;
13
50-59
MissingFormLabel
- 17
Rajasekaran S, Vidyadhara S, Ramesh P. et al .
Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic
pedicle screws in deformity correction surgeries.
Spine.
2007;
32
E56-E64
MissingFormLabel
- 18
Parikh K, Tomasino A, Knopman J. et al .
Operative results and learning curve: microscope-assisted tubular microsurgery for
1- and 2-level discectomies and laminectomies.
Neurosurg Focus.
2008;
25
E14
MissingFormLabel
- 19
Palmer S, Turner R, Palmer R.
Bilateral decompression of lumbar spinal stenosis involving a unilateral approach
with microscope and tubular retractor system.
J Neurosurg.
2002;
97
213-217
MissingFormLabel
- 20
Palmer S.
Use of a tubular retractor system in microscopic lumbar discectomy: 1 year prospective
results in 135 patients.
Neurosurg Focus.
2002;
13
E5
MissingFormLabel
- 21
Hott JS, Deshmukh VR, Klopfenstein JD. et al .
Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases.
Neurosurgery.
2004;
54
1131-1136
; discussion 1136-1137
MissingFormLabel
- 22
Hott JS, Papadopoulos SM, Theodore N. et al .
Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first
52 cases.
Spine.
2004;
29
2856-2860
MissingFormLabel
- 23
Braun V, Rath SA, Antoniadis G. et al .
In vivo experiences with frameless stereotactically guided screw placement in the
spine − results from 75 consecutive cases.
Neurosurg Rev.
2001;
24
74-79
MissingFormLabel
Correspondence
R. Härtl
Departent of Neurosurgery
Brain and Spine Center
Weill Cornell Medical College
1300 York Ave
10065 New York
USA
Phone: +1/212/746 5543
Fax: +1/212/746-8947
Email: harry.gebhard@gmail.com