J Reconstr Microsurg 2011; 27(2): 139-140
DOI: 10.1055/s-0030-1267386
LETTER TO THE EDITOR

© Thieme Medical Publishers

Using a Punch Biopsy to Fashion an Arteriotomy for End-to-Side Anastomosis

J.B. Lynch1 , A.J. Hussey1 , S.T. O'Sullivan1
  • 1Department of Plastic Surgery, Cork University Hospital, Cork, Ireland
Further Information

Publication History

Publication Date:
13 October 2010 (online)

An end-to-side microsurgical vascular anastomosis involves the creation of an arteriotomy in the recipient vessel to facilitate the attachment of a donor vessel. We describe the use of a punch biopsy forceps as a simple, effective, and novel aid to performing an end-to-side arterial anastomosis.

REFERENCES

  • 1 Carrel A. Surgical technique for vascular anastomosis and organ transplants [French].  Lyon Med. 1906;  98 859-863
  • 2 Yu H L. Manageable microsurgical technique for creating an opening in small vessels for end-to-side anastomosis.  J Reconstr Microsurg. 2002;  18 169-172
  • 3 Hallock G G, Rice D C. Use of a micropunch for arteriotomy in end-to-side anastomosis.  J Reconstr Microsurg. 1996;  12 59-62 discussion 62-63
  • 4 Korber K E, Kraemer B A, Li Z. Angled side wall microarteriotomy scissors: a new end-to-side microvascular anastomosis instrument.  Microsurgery. 1990;  11 217-219
  • 5 Pederson W C, Sanders W E. Principles of Microvascular Surgery in Greenes Operative Hand Surgery. 4th Ed. Philadelphia, PA: Churchill Livingston.

Dr. Jenny Lynch

Department of Plastic, Reconstructive and Hand Surgery

Cork University Hospital, Cork, Ireland

Email: jennyblynch@gmail.com

    >