Endoscopy 2009; 41(5): 445-448
DOI: 10.1055/s-0029-1214643
Original article

© Georg Thieme Verlag KG Stuttgart · New York

Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience

T.  E.  Yusuf1 , S.  Ho2 , D.  A.  Pavey3 , H.  Michael4 , F.  G.  Gress1
  • 1Division of Gastroenterology and Hepatology
    SUNY Downstate Medical Center, Brooklyn, New York, USA
  • 2Division of Gastroenterology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA
  • 3Division of Gastroenterology, Duke University Medical Center, Durham, North Carolina, USA
  • 4Division of Gastroenterology, Hepatology, and Nutrition, Winthrop University Hospital, Mineola, New York, USA
Further Information

Publication History

submitted 5 July 2008

accepted after revision 4 March 2009

Publication Date:
05 May 2009 (online)

Background and study aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is now performed routinely in many advanced endoscopy centers and has enhanced the ability to diagnose pancreatic masses. However, there is uncertainty about which needle size is optimal for EUS-FNA of pancreatic masses. We aimed to evaluate the performance of the 22-gauge and 25-gauge needles in obtaining cytologic diagnosis of pancreatic masses.

Methods: All cases that were referred for EUS-FNA for pancreatic masses between February 2001 and June 2007 were reviewed, and patients who underwent EUS-FNA using the 22-gauge and 25-gauge needle system were identified. In patients who underwent surgery, operative histopathological findings were compared with the cytopathological findings from EUS-FNA.

Results: A total of 842 patients with pancreatic masses detected on computed tomography (CT) and/or magnetic resonance imaging (MRI) and confirmed by EUS underwent EUS-FNA with the 22-gauge needle (n = 540) or the 25-gauge needle (n = 302). Results of EUS-FNA cytology findings were compared with the gold standard of surgical histopathological findings or long-term clinical follow-up. The sensitivity, specificity, PPV, and NPV of FNA were respectively 84 %, 100 %, 100 %, and 49 % for the 22-gauge needle compared with 92 %, 97 %, 98 %, and 89 %, respectively for the 25-gauge needle. No complications were noted in the 25-gauge needle group, compared with pancreatitis in 2 % of the 22-gauge needle group.

Conclusions: This retrospective comparative study shows that EUS-FNA with a 25-gauge needle system is a safe and reliable method for tissue sampling in pancreatic masses. The system is more sensitive and has a higher NPV than the standard 22-gauge needle. Our study suggests that perhaps the smaller caliber FNA needle causes less trauma during EUS-FNA and hence less complications. Further studies including randomized trials are needed.

References

  • 1 Chang K J, Katz K D, Durbin T E. et al . Endoscopic ultrasound-guided fine-needle aspiration.  Gastrointest Endosc. 1994;  40 694-699
  • 2 Chang K J, Nguyen P, Erickson R A. et al . The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic carcinoma.  Gastrointest Endosc. 1997;  45 387-393
  • 3 Faigel D O, Ginsberg G G, Bentz J S. et al . Endoscopic ultrasound-guided real-time fine-needle aspiration biopsy of the pancreas in cancer patients with pancreatic lesions.  J Clin Oncol. 1997;  15 1439-1443
  • 4 Gress F G, Hawes R H, Savides T J. et al . Endoscopic ultrasound-guided fine-needle aspiration biopsy using linear array and radial scanning endosonography.  Gastrointest Endosc. 1997;  45 243-250
  • 5 Gress F G, Savides T J, Sandler A. et al . Endoscopic ultrasonography, fine-needle aspiration biopsy guided by endoscopic ultrasonography, and computed tomography in the preoperative staging of non-small-cell lung cancer: a comparison study.  Ann Intern Med. 1997;  127 604-612
  • 6 Ikenberry S, Gress F, Savides T. et al . Fine-needle aspiration of posterior mediastinal lesions guided by radial scanning endosonography.  Gastrointest Endosc. 1996;  43 605-610
  • 7 Vilmann P, Hancke S. A new biopsy handle instrument for endoscopic ultrasound-guided fine-needle aspiration biopsy.  Gastrointest Endosc. 1996;  43 238-242
  • 8 Vilmann P, Hancke S, Henriksen F W. et al . Endosonographically-guided fine needle aspiration biopsy of malignant lesions in the upper gastrointestinal tract.  Endoscopy. 1993;  25 523-527
  • 9 Vilmann P, Hancke S, Henriksen F W. et al . Endoscopic ultrasonography-guided fine-needle aspiration biopsy of lesions in the upper gastrointestinal tract.  Gastrointest Endosc. 1995;  41 230-235
  • 10 Wiersema M J, Kochman M L, Chak A. et al . Real-time endoscopic ultrasound-guided fine-needle aspiration of a mediastinal lymph node.  Gastrointest Endosc. 1993;  39 429-431
  • 11 Wiersema M J, Kochman M L, Cramer H M. et al . Endosonography-guided real-time fine-needle aspiration biopsy.  Gastrointest Endosc. 1994;  40 700-707
  • 12 Wiersema M J, Vilmann P, Giovannini M. et al . Endosonography-guided fine-needle aspiration biopsy: diagnostic accuracy and complication assessment.  Gastroenterology. 1997;  112 1087-1095
  • 13 Peng H Q, Greenwald B D, Tavora F R. et al . Evaluation of performance of EUS-FNA in preoperative lymph node staging of cancers of esophagus, lung, and pancreas.  Diagn Cytopathol. 2008;  36 290-296
  • 14 Vazquez-Sequeiros E, Foruny-Olcina J R. Linear EUS: the clinical impact of N staging in esophageal carcinoma.  Minerva Med. 2007;  98 313-319
  • 15 Ang T L, Tee A K, Fock K M. et al . Endoscopic ultrasound-guided fine needle aspiration in the evaluation of suspected lung cancer.  Respir Med. 2007;  101 1299-1304
  • 16 Matthes K, Bounds B C, Collier K. et al . EUS staging of upper GI malignancies: results of a prospective randomized trial.  Gastrointest Endosc. 2006;  64 496-502
  • 17 Ganpathi I S, So J B, Ho K Y. Endoscopic ultrasonography for gastric cancer: does it influence treatment?.  Surg Endosc. 2006;  20 559-562
  • 18 Tournoy K G, Ryck F D, Vanwalleghem L. et al . The yield of endoscopic ultrasound in lung cancer staging: does lymph node size matter?.  J Thorac Oncol. 2008;  3 245-249
  • 19 Binmoeller K F, Jabusch H C, Seifert H. et al . Endosonography-guided fine-needle biopsy of indurated pancreatic lesions using an automated biopsy device.  Endoscopy. 1997;  29 384-388
  • 20 National Cancer Institute .http://seer.cancer.gov/statfacts/html/pancreas.html; Stand: 2008
  • 21 Degirmenci B, Haktanir A, Albayrak R. et al . Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material.  Clin Radiol. 2007;  62 798-803
  • 22 Hanbidge A E, Arenson A M, Shaw P A. et al . Needle size and sample adequacy in ultrasound-guided biopsy of thyroid nodules.  Can Assoc Radiol J. 1995;  46 199-201
  • 23 Magno P, Ko C W, Buscaglia J M. et al . EUS-guided angiography: a novel approach to diagnostic and therapeutic interventions in the vascular system.  Gastrointest Endosc. 2007;  66 587-591
  • 24 Giday S A, Ko C W, Clarke J O. et al . EUS-guided portal vein carbon dioxide angiography: a pilot study in a porcine model.  Gastrointest Endosc. 2007;  66 814-819

T. E. YusufMD 

GI Endoscopy and Pancreato-Biliary Center of Excellence
Division of Gastroenterology and Hepatology
SUNY Downstate Medical Center

450 Clarkson Avenue, Box 1196
Brooklyn, New York 11203-2098

Fax: (718)270-7201

Email: tyusuf@yahoo.com

    >